Search results for "GEANT"
showing 10 items of 65 documents
Hadronic calibration of the ATLAS liquid argon end-cap calorimeter in the pseudorapidity region in beam tests
2004
Abstract A full azimuthal φ -wedge of the ATLAS liquid argon end-cap calorimeter has been exposed to beams of electrons, muons and pions in the energy range 6 GeV ⩽ E ⩽ 200 GeV at the CERN SPS. The angular region studied corresponds to the ATLAS impact position around the pseudorapidity interval 1.6 | η | 1.8 . The beam test setup is described. A detailed study of the performance is given as well as the related intercalibration constants obtained. Following the ATLAS hadronic calibration proposal, a first study of the hadron calibration using a weighting ansatz is presented. The results are compared to predictions from Monte Carlo simulations, based on GEANT 3 and GEANT 4 models.
A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate Ir-192 brachytherapy
2017
PurposeA joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) Ir-19…
L’actionnariat des salariés influencet-il la rémunération des dirigeants ?
2017
International audience; Cet article étudie la relation entre les composantes variables de la rémunération en actions de l’entreprise des dirigeants et des actionnaires salariés. En utilisant un échantillon de données issu du SBF 120 sur la période 2004-2009, nous étudions en particulier : (i) la relation entre le montant des stock-options attribuées aux dirigeants et l’actionnariat salarié ; (ii) la relation entre le rapport du montant des stock-options sur la rémunération totale des dirigeants et l’actionnariat salarié. La relation est significativement négative dans les deux cas montrant que l’actionnariat salarié tend à limiter la composante stok-options de la rémunération des dirigeants…
L’actionnariat des salariés influence-t-il la rémunération des dirigeants ?
2017
International audience; Cet article étudie la relation entre les composantes variables de la rémunération en actions de l’entreprise des dirigeants et des actionnaires salariés. En utilisant un échantillon de données issu du SBF 120 sur la période 2004-2009, nous étudions en particulier : (i) la relation entre le montant des stock-options attribuées aux dirigeants et l’actionnariat salarié ; (ii) la relation entre le rapport du montant des stock-options sur la rémunération totale des dirigeants et l’actionnariat salarié. La relation est significativement négative dans les deux cas montrant que l’actionnariat salarié tend à limiter la composante stok-options de la rémunération des dirigeants…
The ATLAS Simulation Infrastructure
2010
52 páginas, 10 figuras, 18 tablas.-- This article is distributed under the terms of the Creative Commons Attribution Noncommercial License.-- et al. (The ATLAS Collaboration).
GEANT4 simulation of the neutron background of the C6D6 set-up for capture studies at n_TOF
2014
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has beeni mplemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with anatC sample, showing an excellent agreement above 1 keV. At lower energies, an additional compo…
Dosimetry for electron Intra-Operative RadioTherapy: Comparison of output factors obtained through alanine/EPR pellets, ionization chamber and Monte …
2015
Abstract In this work a comparison between the response of alanine and Markus ionization chamber was carried out for measurements of the output factors (OF) of electron beams produced by a linear accelerator used for Intra-Operative Radiation Therapy (IORT). Output factors (OF) for conventional high-energy electron beams are normally measured using ionization chamber according to international dosimetry protocols. However, the electron beams used in IORT have characteristics of dose per pulse, energy spectrum and angular distribution quite different from beams usually used in external radiotherapy, so the direct application of international dosimetry protocols may introduce additional uncer…
The FIRST experiment at GSI
2012
The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at the SIS accelerator of GSI laboratory in Darmstadt has been designed for the measurement of ion fragmentation cross-sections at different angles and energies between 100 and 1000 MeV/nucleon. Nuclear fragmentation processes are relevant in several fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The start of the scientific program of the FIRST experiment was on summer 2011 and was focused on the measurement of 400 MeV/nucleon 12C beam fragmentation on thin (8 mm) graphite target. The detector is partly based on an alread…
Monte Carlo simulation of a single detector unit for the neutron detector array NEDA
2012
WOS: 000301813500009
Characterization of a neutron-beta counting system with beta-delayed neutron emitters
2016
Abstract A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known β-delayed neutron emission properties. The setup consists of BELEN-20, a 4π neutron counter with twenty 3He proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for β counting and a self-triggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, β and β–neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on …