Search results for "GLASS"
showing 10 items of 1153 documents
Influence of prefabricated post dimensions on restored maxillary central incisors
2007
summary The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to …
In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents
2005
Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…
Premolars restored with posts of different materials: fatigue analysis
2011
Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…
Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.
2009
Summary Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…
In Vitro Evaluation of the Biological Effects of ACTIVA Kids BioACTIVE Restorative, Ionolux, and Riva Light Cure on Human Dental Pulp Stem Cells
2019
This study aimed to analyze the biological effects of three new bioactive materials on cell survival, migration, morphology, and attachment in vitro. ACTIVA Kids BioACTIVE Restorative (Pulpdent, Watertown, MA, USA) (Activa), Ionolux (Voco, Cuxhaven, Germany), and Riva Light Cure UV (SDI, Bayswater, Australia) (Riva) were handled and conditioned with a serum-free culture medium. Stem cells from human dental pulp (hDPSCs) were exposed to material extracts, and metabolic activity, cell migration, and cell morphology were evaluated. Cell adhesion to the different materials was analyzed by scanning electron microscopy (SEM). The chemical composition of the materials was evaluated by energy-dispe…
Bond strength and internal adaptation of customized glass fiber posts using different bulk-fill flow resins
2022
Made available in DSpace on 2022-04-29T08:40:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2022-03-01 Background: this study aimed to evaluate the bond strength and internal adaptation of customized glass fiber posts using Bulk Fill flowable composite resins (BF) and conventional composite resin. Materials and Methods: Fifty bovine teeth were randomly divided (n=10) according to the following groups: G1 (control): glass fiber posts were adapted to the root canal and luted with Rely-X ARC cement (3M® ESPE); G2: fiber posts smaller than the root canal diameter were customized using Filtek™ Z350 XT (3M® ESPE) conventional composite resin, and luted similarly to Group 1. G3: posts were c…
dsDNA, ssDNA, G-quadruplex DNA, and nucleosomal DNA electrochemical screening using canthin-6-one alkaloid-modified electrodes
2014
Abstract Microparticulate films of a canthin-6-one alkaloid ( L ), a natural β-carboline alkaloid presenting a characteristic naphtyridone motif, on glassy carbon electrodes yield different, separate voltammetric signals for dsDNA, ssDNA, G-quadruplex DNA, different degrees of DNA methylation and the biomimetic nucleosomal DNA with detection limit of 10 −5 M. This multiple-signal electrochemical behavior is in contrast with conventional use of DNA intercalators, only discriminating between different DNA forms by variations in the intensity of a unique signal. Complementary photochemical and scanning electrochemical microscopy (SECM) data suggest that the differences in the voltammetric res…
Solid-phase FT-Raman determination of caffeine in energy drinks
2005
Abstract A solid-phase vibrational spectrometry-based methodology (solid-phase Fourier transform-Raman spectrometry, SP-FT-Raman) has been developed for caffeine determination in commercial energy drink samples. The Raman spectra of caffeine, fixed on a C18 solid phase packed into a glass tube of 5 mm i.d., was obtained directly between 3500 and 70 cm −1 . In order to quantify caffeine, Raman intensity between 573 and 542 cm −1 corrected using a baseline defined between 580 and 540 cm −1 was used. A repeatability of 3%, as relative standard deviation of five analysis of a 200 mg l −1 concentration, and a limit of detection of 18 mg l −1 were obtained. The SP-FT-Raman procedure provides a sa…
Simple and commercial readily-available approach for the direct use of ionic liquid-based single-drop microextraction prior to gas chromatography
2009
A simple and commercial readily-available approach that enables the direct use of ionic liquid (IL)-based single-drop microextraction (SDME) prior to gas chromatography (GC) is presented. The approach is based on thermal desorption (TD) of the analytes from the IL droplet to the GC system, by using a robust and commercially-available thermodesorption system. For this purpose, a two-glass-tube concentrically disposed system was designed. The inner tube is a laboratory-cut Pyrex tube (20mm length) that houses the ionic liquid droplet from the SDME process, and the outer tube is a commercially-available TD glass tube (187 mm length) commonly employed for stir-bar sorptive extractions (SBSE). I…
Quantification of low levels of amorphous content in sucrose by hyperDSC.
2005
A method was developed for the quantification of low levels of amorphous content in sucrose with hyperDSC. The method was based on the fact that the change of specific heat at the glass transition is linearly proportional to the amorphous content. It was found out that as annealing time increased, the glass transition temperature moved to a higher temperature and the change of specific heat increased. DeltaC(p) for annealed totally amorphous sucrose was 0.761+/-0.012 Jg(-1) degrees C(-1). Synthetic mixtures with various proportions of crystalline and amorphous sucrose were prepared. The following linear regression between DeltaC(p) and amorphous content was obtained: DeltaC(p)=0.0075x - 0.0…