Search results for "GRAFTING"
showing 10 items of 201 documents
Histological and histomorphometric study using an ultrasonic crestal sinus grafting procedure: a multicenter case study
2016
Background: The aim of this study was to evaluate the efficacy of a hydrodynamic ultrasonic driven transcrestal sinus grafting procedure (Intralift ®, Acteon Company, Bordeaux, France) and the use of a bovine high temperature sintered grafting material in sinus sites with less than 5 mm remaining bone height with no additional autogenous bone in order to create a sufficient recipient site for implants. Material and Methods: 12 patients (16 sinus) in this multicenter case study were included. Using a crestal approach, bone under the sinus was prepared with ultrasonic tips until the Schneiderian membrane was reached. With a trumpet shaped instrument, the Schneiderian membrane was elevated. In…
Autogenous calvarium bone grafting as a treatment for severe bone resorption in the upper maxilla : a case report
2008
Atrophic maxilla rehabilitation has been the subject of several studies for decades; despite this, there are still many different therapeutic choices for the best way to treat maxillary resorption in order to enable implant placement and integration. These possibilities include the optimal use of remaining bone structures, such as the pterygoid processes or zygomatic arch, which involves using zygomaticus and pterygoid implants in combination with standard implants placed in the residual bone; alternatively, regenerative techniques, alveolar bone expansion/distraction or bone grafting techniques may be used. Severe maxillary atrophy has a multifactorial aetiology; the most important factors…
Automated Weaning from Mechanical Ventilation after Off-Pump Coronary Artery Bypass Grafting
2017
Background The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the…
The Artek cup for total hip replacement of dysplastic hip joints.
2003
One specific difficulty in total hip replacement for developmental dysplasia of the hip is a shallow acetabulum with a short anteroposterior diameter. In a prospective cohort study we investigated the short-term results of the Artek cup, designed with a shallow outline and a height-reduced metal inlay for a large size 38 mm metal head, in a group of female patients with mild dysplasia of the hip.Fourteen consecutive patients with 17 dysplastic hip joints were included in the study. Their average age was 42 years. Fourteen hips had dysplasia Crowe grade I; 3 hips had dysplasia Crowe grade II. The femoral head centre was localized according to Pagnano in zone 1 in 3 cases, in zone 3 in 6 case…
Peri-implant defect grafting with autogenous bone or bone graft material in immediate implant placement in molar extraction sites-1- to 3-year result…
2020
Objectives To evaluate the survival rate, the orobuccal bone resorption and stability of peri-implant hard and soft tissues following immediate implant placement of wide diameter implants in molar extraction sites and peri-implant defect grafting with autogenous bone (AB) or biphasic bone graft material (BBGM) with 1- to 3-year follow-up examinations. Material and methods Fifty wide diameter implants were placed in 50 patients immediately into molar extraction sockets by a flapless approach. Peri-implant defect augmentation was performed randomized with either AB or BBGM. Primary outcome variable was implant survival. Marginal bone level changes, orobuccal width of the alveolar crest, probi…
Photografted fluoropolymers as novel chromatographic supports for polymeric monolithic stationary phases
2018
[EN] In this study, porous polymer monoliths were in situ synthesized in fluoropolymers tubing to prepare microbore HPLC columns. To ensure the formation of robust homogeneous polymer monoliths in these housing supports, the inner surface of fluoropolymer tubing was modified in a two-step photografting process. Raman spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the inner poly(ethylene-co-tetrafluoroethylene) (ETFE) wall and the subsequent attachment of a monolith onto the wall. Poly(glycidyl methacrylate-co-divinylbenzene), poly(butyl methacrylate-co-ethyleneglycol dimethacrylate) and poly(styrene-co-divinylbenzene) monoliths were in situ synt…
Comparative Study of Different Maleic Anhydride Grafted Compatibilizer Precursors toward LDPE/PA6 Blends: Morphology and Mechanical Properties
2005
The study deals with the effectiveness of maleic anhydride grafted styrene-b-ethylene-co-propylene copolymer (SEPMA) as compatibilizer precursor (CP) for blends of low density polyethylene (LDPE) with polyamide-6 (PA). The CP was produced by grafting MA onto SEP in the melt. The specific interactions between the CP and the blends components have been investigated through characterizations of the binary LDPE/CP and PA/CP blends. The compatibilizing efficiency of the MA-grafted SEP, as revealed by the thermal properties and the morphology of the compatibilized blends, has been shown to be excellent. The morphology, as well as the mechanical properties of the compatibilized with SEPMA 75/25 w/…
ADVANCES IN VEGETABLE GRAFTING AND NEW NURSERY PATTERNS FOR GRAFTED PLANT PRODUCTION
2014
GraftFast Surface Engineering to Improve MOF Nanoparticles Furtiveness
2018
International audience; Controlling the outer surface of nanometric metal–organic frameworks (nanoMOFs) and further understanding the in vivo effect of the coated material are crucial for the convenient biomedical applications of MOFs. However, in most studies, the surface modification protocol is often associated with significant toxicity and/or lack of selectivity. As an alternative, how the highly selective and general grafting GraftFast method leads, through a green and simple process, to the successful attachment of multifunctional biopolymers (polyethylene glycol (PEG) and hyaluronic acid) on the external surface of nanoMOFs is reported. In particular, effectively PEGylated iron trime…
Production of polymeric micro- and nanostructures with tunable properties as pharmaceutical delivery systems
2020
Abstract The production of novel graft copolymers based on poly-e-caprolactone (PCL) and polyaspartamide are useful to realize structures for potential biomedical applications. Here, the synthesis of pegylated PCL/polyhydroxyethyl aspartamide (PHEA) graft copolymers (PHEA-g-SUCC-PCL-g-PEG) with tunable composition, was achieved by followpling a synthetic strategy that involved first the grafting of preformed PCL on PHEA backbone, then polyethylen glycol (PEG), by using 1,1′-carbonyldiimidazole (CDI) to speed up the condensation reaction. Graft copolymers with a Derivatization Degree (DD) in PCL ranging between 1.1 and 4.4 mol% were obtained, and processable with different technologies for t…