Search results for "Goniometer"

showing 10 items of 19 documents

Experimental Equipment for Studying the Residual Stresses Developed During High Temperature Reactions by X-Ray Diffraction

1996

This paper describes a device dedicated to studyng, by X-ray diffraction the residual stresses developed on surface samples as a function of temperature and atmosphere conditions. The setup consists of : a.) an horizontal axis goniometer which allows the programmed positionning of the sealed X-ray source and of the linear detector. b.) a high temperature controlled atmosphere chamber Particular attention has been paid to the thermal stability up to 1200°C and the accurate position on the sample.

010302 applied physicsDiffractionControlled atmosphereChemistrybusiness.industryDetectorGeneral Physics and Astronomy02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesAtmosphereOpticsResidual stressGoniometer[PHYS.HIST]Physics [physics]/Physics archives0103 physical sciencesX-ray crystallographyThermal stability0210 nano-technologybusiness
researchProduct

Fast-ADT: A fast and automated electron diffraction tomography setup for structure determination and refinement.

2020

Abstract Electron crystallography has focused in the last few years on the analyses of microcrystals, mainly organic compounds, triggered by recent publications on acquisition methods based on direct detection cameras and continuous stage tilting. However, the main capability of a transmission electron microscope is the access to features at the nanometre scale. In this context, a new acquisition method, called fast and automated diffraction tomography (Fast-ADT), has been developed in form of a general application in order to get the most of the diffraction space from a TEM. It consists of two subsequent tilt scans of the goniometric stage; one to obtain a crystal tracking file and a secon…

010302 applied physicsDiffractionMaterials scienceMicroscopeElectron crystallographybusiness.industryContext (language use)02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionDiffraction tomographyOpticsElectron diffractionlawGoniometer0103 physical sciences0210 nano-technologybusinessInstrumentationPowder diffractionUltramicroscopy
researchProduct

Concurrent Criterion-related Validity, Reliability, and Responsiveness to Treatment of the Figure-of-Four Position for Measurement of Anterior Hip Jo…

2018

Abstract Objective The objective of this study was to examine the intra- and intertester reliability, concurrent criterion-related validity, and responsiveness to treatment of the “figure-of-four” position. Methods A total of 52 asymptomatic male soccer players participated in this study. The intraclass correlation coefficient (2, 1) was used to determine intra- and intertester reliability of the figure-of-four position. Pearson product moment correlation coefficients examining the association between the figure-of-four position and goniometric measurements of hip extension and external rotation were used to establish concurrent validity. To evaluate responsiveness to treatment, the figure-…

AdultMaleRange of Motion Articular/physiologyRotationIntraclass correlationConcurrent validity03 medical and health sciencessymbols.namesake0302 clinical medicinePosition (vector)mental disordersSoccerCriterion validityMedicineHumansRange of Motion ArticularMuscle SkeletalReliability (statistics)Orthodontics030222 orthopedicsbusiness.industrySoccer/physiologyReproducibility of Results030229 sport sciencesPearson product-moment correlation coefficientHip Joint/physiologyBiomechanical PhenomenaMuscle Skeletal/physiologyHip extensionGoniometersymbolsFemaleHip JointChiropracticsbusinessJournal of manipulative and physiological therapeutics
researchProduct

Assessment of Kinect V2 for elbow range of motion estimation in people with haemophilia using an angle correction model

2018

Introduction The joint range of motion (ROM) is an important clinical parameter used to assess the loss of functionality resulting from joint bleedings in people with haemophilia. These episodes require a close follow-up and, to decrease patients' hospital dependence, telemedicine tools are needed. Therefore, this study is aimed to analyse the validity of the Microsoft Kinect V2 sensor with corrected angle measurement to be used in the monitoring of elbow ROM in people with haemophilia. Methods A convenience sample of 10 healthy controls (CG) and 10 patients with haemophilia with elbow arthropathy (HG) participated in this study. Full ROM of elbow joints was measured in the frontal view wit…

AdultMalemedicine.medical_specialtyWilcoxon signed-rank testElbow030204 cardiovascular system & hematologyHemophilia AHaemophiliarange of motion03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationElbow JointHemarthrosisArthropathymedicineElbow jointsupper extremityHumansRange of Motion ArticularGenetics (clinical)Models Statisticalbusiness.industryLimits of agreementhaemophilic arthropathy3D depth sensorHematologyGeneral Medicinemedicine.diseasemedicine.anatomical_structureGoniometerFemaleRange of motionbusinessgoniometry030215 immunology
researchProduct

Experimental system for the study of the directional thermal emission of natural surfaces

2004

A new automatic experimental system was designed to improve the accuracy of multidirectional thermal infrared measurements. This experimental system mainly consists of two identical thermal cameras operating at 8-13 mu m, one metal ring to keep the constant view area for different view angles and a goniometer, which is composed of: (1) a semicircular roadway of 2 m diameter to change the observation angle in the azimuth direction; (2) an elevator of 1 m height to adjust the measuring level to the target level; (3) a rotating arm equipped with one thermal camera for changing the observation angle in the zenith direction; and (4) a fixed arm equipped with another thermal camera to record at n…

AzimuthOpticsData acquisitionMaterials sciencebusiness.industryBrightness temperatureInstrumentationGoniometerThermalNadirGeneral Earth and Planetary SciencesbusinessZenithInternational Journal of Remote Sensing
researchProduct

Angular dependence of the emissivity of bare soils in the thermal infrared

2009

Emissivity is one of the main factors to take into account when studying processes that take place in the Earth surface by using radiance measurements in the thermal infrared, such as surface energy balance, land surface temperature (LST) retrieval, classification of different types of surface, etc. For this reason it is necessary to study the factors that can influence the emissivity. The present work evaluates one of these factors: the variation of the emissivity with the zenithal observation angle over bare soils, specifically the variation of the relative emissivity calculated from measurements of radiances, almost simultaneous, at nadir (0o) and at a certain angle (Θ). The measurements…

AzimuthWork (thermodynamics)Materials scienceGoniometerSoil waterNadirRadianceEmissivityQuartzRemote sensing2009 IEEE International Geoscience and Remote Sensing Symposium
researchProduct

An improved goniometer head for high-temperature single-crystal X-ray diffraction

1999

A reliable and inexpensive goniometer head has been designed. Its stability, resulting from its compact construction, makes it very suitable for accurate measurements. Moreover, its space-saving design facilitates its application in X-ray data collection using charge-coupled device (CCD) detectors. This head has been improved for high-temperature measurements and has been tested by comparison of accurate K0.88Rb0.12TiOPO4data collected both at room temperature and at 973 K on the same crystal. The excellent structure results obtained at 973 K during the 360 h of measurements prove the stability of the goniometer head.

CrystalCrystallographyOpticsbusiness.industryChemistryGoniometerDetectorX-ray crystallographyHead (vessel)businessSingle crystalGeneral Biochemistry Genetics and Molecular BiologyJournal of Applied Crystallography
researchProduct

3D Electron Diffraction: The Nanocrystallography Revolution

2019

Crystallography of nanocrystalline materials has witnessed a true revolution in the past 10 years, thanks to the introduction of protocols for 3D acquisition and analysis of electron diffraction data. This method provides single-crystal data of structure solution and refinement quality, allowing the atomic structure determination of those materials that remained hitherto unknown because of their limited crystallinity. Several experimental protocols exist, which share the common idea of sampling a sequence of diffraction patterns while the crystal is tilted around a noncrystallographic axis, namely, the goniometer axis of the transmission electron microscope sample stage. This Outlook review…

DiffractionMaterials scienceCryo-electron microscopyPhysical and chemical processesGeneral Chemical Engineering010402 general chemistry01 natural sciencesCrystalsCrystalOpticsQD1-999Structure determinationMaterials010405 organic chemistrybusiness.industryCrystal structureGeneral ChemistryNanocrystalline material0104 chemical sciencesChemistryElectron diffractionTransmission electron microscopyGoniometer[PHYS.COND.CM-MS]Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]businessProtein crystallizationOutlook
researchProduct

The use of dry needling to treat painful shoulder syndrome: a case report

2020

Background. Painful shoulder syndrome is a common condition in society. Most patients experience pain and reduced mobility of the affected limb, which can have an impact on the quality of life. This report presents a case of a patient with pain and reduced range of motion in the left shoulder. Aim of the study. The study aim was to evaluate the efficacy of dry needling in the treatment of painful shoulder syndrome, based on functional measures of pain, disability and range of motion. Case report. A 42-year old patient reported pain in her left shoulder. A series of 6 dry needling sessions were performed, twice a week, for a period of 3 weeks. Prior to, and immediately after, the therapy a s…

Dry needlingmedicine.medical_specialtypainful shoulder syndromebusiness.industryMedicineVAS scalePainful shouldergoniometerbusinessdry needlingLaitinen QuestionnaireSurgeryMedical Science Pulse
researchProduct

Angular Dependency of Hyperspectral Measurements over Wheat Characterized by a Novel UAV Based Goniometer

2015

In this study we present a hyperspectral flying goniometer system, based on a rotary-wing unmanned aerial vehicle (UAV) equipped with a spectrometer mounted on an active gimbal. We show that this approach may be used to collect multiangular hyperspectral data over vegetated environments. The pointing and positioning accuracy are assessed using structure from motion and vary from σ = 1° to 8° in pointing and σ = 0.7 to 0.8 m in positioning. We use a wheat dataset to investigate the influence of angular effects on the NDVI, TCARI and REIP vegetation indices. Angular effects caused significant variations on the indices: NDVI = 0.83–0.95; TCARI = 0.04–0.116; REIP = 729–735 nm. Our analysis high…

HyperspectralvegetationSciencevegetation indicesQHyperspectral; Unmanned aerial vehicle (UAV); vegetation; bidirectional reflectance distribution function (BRDF); goniometer; vegetation indicesUnmanned aerial vehicle (UAV)ddc:620bidirectional reflectance distribution function (BRDF)goniometer
researchProduct