Search results for "Heart"

showing 10 items of 3201 documents

In Silico Shear and Intramural Stresses are Linked to Aortic Valve Morphology in Dilated Ascending Aorta

2017

Objective/Background: The development of ascending aortic dilatation in patients with bicuspid aortic valve (BAV) is highly variable, and this makes surgical decision strategies particularly challenging. The purpose of this study was to identify new predictors, other than the well established aortic size, that may help to stratify the risk of aortic dilatation in BAV patients.Methods: Using fluid-structure interaction analysis, both haemodynamic and structural parameters exerted on the ascending aortic wall of patients with either BAV ( n = 21) or tricuspid aortic valve (TAV; n = 13) with comparable age and aortic diameter (42.7 +/- 5.3 mm for BAV and 45.4 +/- 10.0 mm for TAV) were compared…

Aortic valveMalePatient-Specific ModelingComputed Tomography AngiographyHeart Valve DiseasesHemodynamics02 engineering and technology030204 cardiovascular system & hematology0302 clinical medicineBicuspid aortic valveBicuspid Aortic Valve DiseaseRisk FactorsAortaSinotubular JunctionModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeComputational modelingAneurysm of ascending aortaMiddle AgedAortic AneurysmHeart Valve Diseasemedicine.anatomical_structureAortic Valvecardiovascular systemCardiologyWall shear streFemaleCardiology and Cardiovascular MedicineBlood Flow VelocityDilatation PathologicHumanmedicine.medical_specialtyBicuspid aortic valve0206 medical engineeringAortography03 medical and health sciencesInternal medicinemedicine.arteryAscending aortamedicineHumansAgedAortabusiness.industryRisk FactorSignificant differenceHemodynamicsmedicine.disease020601 biomedical engineeringAortic wallRegional Blood FlowSurgeryStress Mechanicalbusiness
researchProduct

Focus on the unique mechanisms involved in thoracic aortic aneurysm formation in bicuspid aortic valve versus tricuspid aortic valve patients: clinic…

2013

OBJECTIVES: The involvement of different factors in the onset of thoracic aortic aneurysm (TAA) in patients with a bicuspid aortic valve (BAV) vs those with a tricuspid aortic valve (TAV) is well recognized. However, the molecular, genetic and cellular mechanisms driving TAA remain unclear. The aim of this study was to identify the different mechanisms involved in TAA development in patients with BAV vs TAV. METHODS: Aorta specimens and DNA samples were collected from 24 BAV (18 men and 6 women; mean age: 54.2 ± 14.39 years) and 110 TAV (79 men and 31 women, mean age: 66 ± 9.8 years) patients. A control group of 128 subjects (61 men and 67 woman, mean age: 61.1 ± 5.8 years) was also enrolle…

Aortic valveMaleThoracicHeart Valve DiseasesApoptosisPilot ProjectsBicuspid aortic valve; Clinical implications; Identifying different genetic and histological profiles; Thoracic aortic aneurysm; Tricuspid aortic valve; Adult; Aged; Aortic Aneurysm Thoracic; Aortic Valve; Apoptosis; Comorbidity; Female; Gene Frequency; Genetic Predisposition to Disease; Genotype; Heart Valve Diseases; Histocytochemistry; Humans; Male; Matrix Metalloproteinase 9; Middle Aged; Pilot Projects; Polymorphism Single Nucleotide; Risk Factors; Tricuspid ValveComorbidityBicuspid aortic valveBicuspid Aortic Valve DiseaseGene FrequencyFibrosisRisk FactorsClinical implicationsTricuspid valvebiologyHistocytochemistryGeneral MedicineSingle NucleotideMiddle AgedAortic Aneurysmmedicine.anatomical_structureMatrix Metalloproteinase 9Aortic ValveCardiologyFemaleTricuspid ValveCardiology and Cardiovascular MedicinePulmonary and Respiratory MedicineAdultmedicine.medical_specialtyBicuspid aortic valveGenotypeThoracic aortic aneurysmTricuspid aortic valvePolymorphism Single Nucleotidemedicine.arteryInternal medicineThoracic aortic aneurysmAscending aortamedicineSettore MED/05 - Patologia ClinicaHumansGenetic Predisposition to DiseasePolymorphismIdentifying different genetic and histological profilesAgedAortaAortic Aneurysm Thoracicbusiness.industryAngiotensin-converting enzymeSettore MED/23 - Chirurgia Cardiacamedicine.diseasebiology.proteinSurgerybusinessEuropean journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
researchProduct

A multicentre European registry to evaluate the Direct Flow Medical transcatheter aortic valve system for the treatment of patients with severe aorti…

2016

Aims Our aim was to assess the clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System (DFM-TAVS), when used in routine clinical practice. Methods and results This is a prospective, open-label, multicentre, post-market registry of patients treated with DFM-TAVS according to approved commercial indications. Echocardiographic and angiographic data were evaluated by an independent core laboratory and adverse events were adjudicated and classified according to VARC-2 criteria by an independent clinical events committee. The primary endpoint was freedom from all-cause mortality at 30 days post procedure. Secondary endpoints included procedural, early safety and efficacy en…

Aortic valveMalemedicine.medical_specialtyCardiac Catheterizationmedicine.medical_treatmentAortic Valve InsufficiencyRegurgitation (circulation)030204 cardiovascular system & hematologyTranscatheter Aortic Valve Replacement03 medical and health sciences0302 clinical medicineRisk FactorsInternal medicinemedicineClinical endpointHumans030212 general & internal medicineHeart valveProspective StudiesRegistriesCardiac catheterizationAgedAged 80 and overHeart Valve Prosthesis Implantationbusiness.industryAortic Valve Stenosismedicine.disease3. Good healthClinical trialStenosismedicine.anatomical_structureTreatment OutcomeAortic valve stenosisAortic ValveHeart Valve ProsthesisCardiologyFemaleCardiology and Cardiovascular MedicinebusinessEuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
researchProduct

Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve.

2012

The aortic dissection (AoD) of an ascending thoracic aortic aneurysm (ATAA) initiates when the hemodynamic loads exerted on the aneurysmal wall overcome the adhesive forces holding the elastic layers together. Parallel coupled, two-way fluid–structure interaction (FSI) analyses were performed on patient-specific ATAAs obtained from patients with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) to evaluate hemodynamic predictors and wall stresses imparting aneurysm enlargement and AoD. Results showed a left-handed circumferential flow with slower-moving helical pattern in the aneurysm's center for BAV ATAAs whereas a slight deviation of the blood flow toward the anterolater…

Aortic valveMalemedicine.medical_specialtyFluid–structure interaction Aortic dissection Ascending thoracic aortic aneurysm Bicuspid aortic valveBiomedical EngineeringBiophysicsHeart Valve DiseasesAorta ThoracicThoracic aortic aneurysmArticleAortic aneurysmBicuspid aortic valveBicuspid Aortic Valve DiseaseInternal medicinemedicine.arteryCoronary CirculationAscending aortamedicineThoracic aortaHumansOrthopedics and Sports Medicinecardiovascular diseasesAgedAortic dissectionAortabusiness.industryRehabilitationHemodynamicsModels CardiovascularMiddle Agedmedicine.diseaseElasticityAortic Aneurysmmedicine.anatomical_structureAortic ValveCardiologycardiovascular systemFemaleTricuspid ValvebusinessJournal of biomechanics
researchProduct

Value and limitations of transesophageal echocardiography in the evaluation of aortic prostheses.

1993

Results of 34 transesophageal (TEE) studies in patients with suspected aortic prosthetic dysfunction were compared with transthoracic echocardiographic (TTE) results and to anatomic findings. Mass lesions noted at surgery (autopsy) were correctly described in 93% by TEE versus 43% by TTE. Abscesses were detected in 88% by TEE versus 18% by TTE. Bioprosthetic degeneration was visualized in 88% versus 38% and prosthetic obstruction correctly identified in 75% versus 50% by TEE and TTE, respectively. Anatomic aortic regurgitant lesions were identified in 96% by TEE versus 77% by TTE, whereas the correct origin was detected in 88% of cases by TEE versus 54% of cases by TTE. TEE provides valuabl…

Aortic valveMalemedicine.medical_specialtyProsthesis-Related InfectionsAortic Valve InsufficiencyAutopsySensitivity and SpecificityPostoperative ComplicationsPredictive Value of TestsmedicineHumansRadiology Nuclear Medicine and imagingIn patientProspective StudiesBioprosthesisbusiness.industryThrombosisbody regionsmedicine.anatomical_structureEchocardiographyAortic ValveHeart Valve ProsthesisFemaleRadiologyCardiology and Cardiovascular Medicinebusinesshuman activitiesJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct

Modified hemi-Fontan procedure on the beating heart

1998

the heart by infusing the cardioplegic solution under aortic occlusion by means of the balloon throughout the procedure. Even though the balloon catheter passes through the aortic valve, significant aortic valve insufficiency is not likely to occur because of the small caliber of the balloon catheter. We believe that the clinical application of this double-lumen aortic occlusion catheter will protect the myocardium in patients with a thoracoabdominal aortic aneurysm or distal descending aortic aneurysm who undergo the operation through the left thoracotomy with DHCA.

Aortic valvePulmonary and Respiratory Medicinemedicine.medical_specialtyBeating heartmedicine.medical_treatmentFontan ProcedureBalloonAortic aneurysmHemi-Fontan ProcedureInternal medicineHypoplastic Left Heart SyndromemedicineHumansThoracotomyCardiopulmonary Bypassbusiness.industryAnastomosis SurgicalBalloon catheterInfantmedicine.diseaseSurgeryCathetermedicine.anatomical_structurecardiovascular systemCardiologySurgerybusinessCardiology and Cardiovascular MedicineThe Journal of Thoracic and Cardiovascular Surgery
researchProduct

Transcatheter Heart Valve Implantation in Bicuspid Patients with Self-Expanding Device

2021

Bicuspid aortic valve (BAV) patients are conventionally not treated by transcathether aortic valve implantation (TAVI) because of anatomic constraint with unfavorable outcome. Patient-specific numerical simulation of TAVI in BAV may predict important clinical insights to assess the conformability of the transcathether heart valves (THV) implanted on the aortic root of members of this challenging patient population. We aimed to develop a computational approach and virtually simulate TAVI in a group of n.6 stenotic BAV patients using the self-expanding Evolut Pro THV. Specifically, the structural mechanics were evaluated by a finite-element model to estimate the deformed THV configuration in …

Aortic valveTechnologymedicine.medical_specialtybicuspid aortic valveQH301-705.5medicine.medical_treatment0206 medical engineeringDiastoleBioengineering02 engineering and technology030204 cardiovascular system & hematologyBicuspid aortic valve Finite-element analysis Fluid–solid interaction Transcatheter aortic valve implantationArticle03 medical and health sciences0302 clinical medicineBicuspid aortic valveInternal medicinemedicine.arterymedicineCardiac skeletonHeart valveBiology (General)transcatheter aortic valve implantationAortabusiness.industryTSettore ING-IND/34 - Bioingegneria IndustrialeStentmedicine.diseasefluid–solid interaction020601 biomedical engineeringAortic wallmedicine.anatomical_structurefinite-element analysiscardiovascular systemCardiologybusinessBioengineering
researchProduct

TAVI imaging: over the echocardiography

2020

Aortic valve stenosis (AS) is a common valvular heart disease. Recently, transcatheter aortic valve implantation (TAVI) has changed the treatment of severe AS in elderly patients with contraindications to traditional surgical replacement. Echocardiography is conventionally used as the first imaging modality to assess the presence and severity of AS and to provide anatomical and functional information. Nowadays, imaging techniques play a crucial role in the planning of TAVI to define suitable candidates. Computed tomography (CT) is essential to display the anatomy of the aortic valve complex (including aortic annulus, Valsalva sinuses, coronary arteries ostia, sinotubular junction), thoracoa…

Aortic valvemedicine.medical_specialtyAortic valve stenosisCoronary Angiography030218 nuclear medicine & medical imagingTranscatheter Aortic Valve Replacement03 medical and health sciences0302 clinical medicineMagnetic resonance imagingmedicineHumansRadiology Nuclear Medicine and imagingCardiac skeletonComputed tomographyNeuroradiologyAgedIncidental FindingsTranscatheter aortic valve implantationmedicine.diagnostic_testbusiness.industryvalvular heart diseaseSettore ING-IND/34 - Bioingegneria IndustrialeMagnetic resonance imagingInterventional radiologyGeneral Medicinemedicine.diseaseCoronary arteriesmedicine.anatomical_structureEchocardiography030220 oncology & carcinogenesisAortic valve stenosiscardiovascular systemRadiologybusinessTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Valvular Heart Disease

2013

Valvular heart disease (VHD) refers to a wide spectrum of cardiac disorders that affect a large number of patients. Echocardiography is still considered the pivotal imaging method to evaluate the cardiac valves. However, echocardiography has some intrinsic limitations due to operator dependence and patient habitus. In the last two decades three-dimensional techniques such as magnetic resonance imaging (MRI) and computed tomography (CT) have provided valuable assessment of VHD. MRI overcomes the limitation of the poor acoustic window of echocardiography without ionizing radiation. Nowadays, MRI aims to be considered as the reference standard for imaging cardiac valves because of the improved…

Aortic valvemedicine.medical_specialtyMitral regurgitationmedicine.diagnostic_testbusiness.industryvalvular heart diseaseMagnetic resonance imaging030204 cardiovascular system & hematologymedicine.disease3. Good health030218 nuclear medicine & medical imagingCoronary artery disease03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureMitral valveValvular Heart DiseaseAngiographyCardiac valvemedicineRadiologybusinessSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Chronic atrial fibrillation in presence of aortic stenosis in a patient with polysplenia syndrome.

2013

We report a rare case of “situs viscerum ambiguous” with polysplenia syndrome, in a 69 year old female patient with aortic stenosis and chronic atrial fibrillation. The presenting symptom was dyspnoea on moderate exertion and an ECG showed supra ventricular arrhythmia. Patients trans-thoracic echocardiogram revealed a dilated left atrium, reduced ejection fraction, mild tricuspid regurgitation, moderate-severe pulmonary hypertension and severe aortic stenosis. The patient was successfully treated with a replacement of her aortic valve and ascending aorta.

Aortic valvemedicine.medical_specialtyPolysplenia syndromeRegurgitation (circulation)Heterotaxy SyndromePolysplenia Aortic Stenosis Atrial Fibrillationmedicine.arteryInternal medicineAscending aortaAtrial FibrillationMedicineChronic atrial fibrillationHumanscardiovascular diseasesAortaAgedHeart Valve Prosthesis ImplantationEjection fractionbusiness.industryGeneral MedicineAortic Valve Stenosismedicine.diseasePulmonary hypertensionSettore MED/11 - Malattie Dell'Apparato CardiovascolareStenosismedicine.anatomical_structureTreatment OutcomeChronic Diseasecardiovascular systemCardiologyFemalebusinessActa clinica Belgica
researchProduct