Search results for "Hemodynamic"

showing 10 items of 526 documents

Blood-brain barrier disruption by low-frequency ultrasound.

2006

Background and Purpose— A recent study showed a dramatic increase in cerebral hemorrhage comprising atypical locations with low-frequency ultrasound–mediated recombinant tissue plasminogen activator–thrombolysis in humans. Here, we provide a possible explanation for this phenomenon by a side effect observed in a study using the similar ultrasound device. Methods— The study was originally undertaken to investigate by transcranial Doppler sonography, positron emission tomography and perfusion MRI whether transcranial application of wide-field low-frequency ultrasound (300 kHz) improves cerebral hemodynamics in patients with cerebral small vessel disease. Results— Showing no clear positive ef…

Malemedicine.medical_specialtyUltrasonography Doppler TranscranialUltrasonic TherapyPerfusion scanningBrain IschemiaBrain ischemiaParietal LobemedicineHumansCerebral perfusion pressureStrokeAgedAdvanced and Specialized Nursingmedicine.diagnostic_testbusiness.industryUltrasoundHemodynamicsMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFrontal LobePositron emission tomographyBlood-Brain BarrierCerebrovascular CirculationPositron-Emission TomographyNeurology (clinical)RadiologyCardiology and Cardiovascular MedicinebusinessPerfusionExtravasation of Diagnostic and Therapeutic MaterialsStroke
researchProduct

Mechanism of the cardiovascular activity of laudanosine: comparison with papaverine and other benzylisoquinolines.

1994

1. The activity of (+/-)-laudanosine, a benzyltetrahydroisoquinoline alkaloid, was investigated in pithed rats and rat isolated aorta. Its effects on [3H]-(+)-cis-diltiazem and [3H]-nitrendipine binding to rat cerebral cortical membranes, and on the different molecular forms of cyclic nucleotide phosphodiesterases (PDE) isolated from bovine aorta were investigated. 2. The dose-response curve to methoxamine (3-300 micrograms kg-1, i.v.) in normotensive pithed rats was shifted to the right by (+/-)-laudanosine, 3 and 6 mg kg-1. 3. (+/-)-Laudanosine inhibited in a concentration-dependent manner the contractile responses evoked by noradrenaline (NA 1 microM), depolarizing solution (KCl 80 mM) o…

Malemedicine.medical_specialtyVascular smooth musclePhosphodiesterase InhibitorsAorta ThoracicPharmacologyIn Vitro TechniquesBinding CompetitiveMethoxamineMuscle Smooth VascularLaudanosinechemistry.chemical_compoundNorepinephrineRadioligand AssayInternal medicinePapaverinemedicineAnimalsRats WistarBenzylisoquinolinePharmacologyDecerebrate StatePapaverineChemistryAlkaloidHemodynamicsPhosphodiesteraseIsoquinolinesRatsEndocrinologyMechanism of actionCalciumCattlemedicine.symptommedicine.drugMuscle ContractionResearch ArticleBritish journal of pharmacology
researchProduct

Color Doppler Imaging of the Ocular Ischemic Syndrome

1992

Purpose: This study describes hemodynamic characteristics of the ophthalmic, central retinal, and posterior ciliary arteries in 16 eyes of 11 patients with the ocular ischemic syndrome. Understanding the hemodynamic characteristics of the retrobulbar circulation may elucidate the natural history and pathophysiology of the ocular ischemic syndrome and perhaps form the basis for rational treatment of this condition. Methods: Color Doppler imaging, a procedure that permits rapid noninvasive imaging of the ophthalmic, central retinal, and posterior ciliary arteries, was used to quantitate peak systolic blood flow velocities and vascular resistance (pulsatility index) within these vessels in stu…

Malemedicine.medical_specialtygenetic structuresFundus OculiRetinal ArteryIschemiaHemodynamicsEyeOphthalmic ArteryIschemiaOphthalmologymedicine.arteryHumansMedicineAgedUltrasonographyAged 80 and overbusiness.industryVascular diseaseCiliary BodySyndromeBlood flowAnatomyMiddle Agedmedicine.diseaseeye diseasesCiliary arteriesOphthalmologymedicine.anatomical_structureOphthalmic arteryVascular resistanceFemalesense organsOcular ischemic syndromebusinessBlood Flow VelocityOphthalmology
researchProduct

Hemodynamic impact of isobaric levobupivacaine versus hyperbaric bupivacaine for subarachnoid anesthesia in patients aged 65 and older undergoing hip…

2014

Background The altered hemodynamics, and therefore the arterial hypotension is the most prevalent adverse effect after subarachnoid anesthesia. The objective of the study was to determine the exact role of local anesthetic selection underlying spinal anesthesia-induced hypotension in the elderly patient. We conducted a descriptive, observational pilot study to assess the hemodynamic impact of subarachnoid anesthesia with isobaric levobupivacaine versus hyperbaric bupivacaine for hip fracture surgery. Description Hundred twenty ASA status I-IV patients aged 65 and older undergoing hip fracture surgery were enrolled. The primary objective of our study was to compare hemodynamic effects based …

Malemedicine.medical_specialtymedicine.drug_classSubarachnoid blockHemodynamicsPilot ProjectsSubarachnoid SpaceHip fractureDatabaseElderlyAnesthesiologymedicineHumansOrthopedic ProceduresAnesthetics LocalLevobupivacaineAgedBupivacaineHip surgeryAged 80 and overHip fractureLocal anestheticbusiness.industryHip FracturesHemodynamicsMiddle Agedmedicine.diseaseBupivacaineAnesthesiology and Pain MedicineBlood pressureAtmospheric PressureLevobupivacaineAnesthesiaRespiratory MechanicsFemaleHypotensionbusinessmedicine.drugAnesthesia LocalBMC Anesthesiology
researchProduct

Combined medical and mechanical recanalization in acute myocardial infarction

1985

A technique of combined medical and mechanical recanalization was employed in 96 patients with acute transmural myocardial infarction. The mean time between onset of symptoms and admission to hospital was 170 +/- 65 min (X +/- SD). After 10 +/- 16 min, 250,000 U streptokinase was administered intravenously for 20 min. Intracoronary thrombolysis was commenced within 38 +/- 14 min. First coronary angiograms demonstrated reperfusion, an open vessel in 25/96 patients (26%). In 15/71 patients (21%) reperfusion occurred during thrombolysis therapy, before mechanical recanalization could be performed. Recanalization was achieved mechanically in 37/71 patients (52%) with occluded coronary vessels. …

Malemedicine.medical_specialtymedicine.medical_treatmentStreptokinaseMyocardial InfarctionCoronary DiseaseAnterior myocardial infarctionElectrocardiographyRecurrenceCoronary CirculationInternal medicinemedicineHumansInfusions ParenteralStreptokinaseMyocardial infarctionAgedChemotherapybusiness.industryHemodynamicsArrhythmias CardiacStroke VolumeThrombolysisMiddle Agedmedicine.diseaseCombined Modality TherapyMyocardial ContractionPeripheralCoronary vesselCardiologyFemaleCardiology and Cardiovascular MedicinebusinessAngioplasty Balloonmedicine.drugIntracoronary thrombolysisCatheterization and Cardiovascular Diagnosis
researchProduct

Tako-tsubo cardiomyopathy and microcirculation.

2010

Takotsubo cardiomyopathy was described for the first time in Japan in the 1990s. It is very similar to the ischemic cardiopathy both for clinical and instrumental characteristics. His peculiarity is an alteration of the ventricular contraction mechanism with hypo-akinesis of the apex and lateral segments of the left ventricle, associated with hyper-kinesis of the heart base which is responsible for the typical echocardiographic aspect of a cruet during the systole. However, the etiology of this cardiomyopathy is still unknown despite the fact that numerous hypothesis have been made. A single study of 16 patients proved multivasal damage by a BLASH SCORE analysis of the coronary radiography.…

Malemedicine.medical_specialtytako-tsubo cardiomyopathyCardiomyopathycoronary microcirculation; takotsubo; timi frame countHemodynamicsHealth InformaticsAnterior Descending Coronary ArteryCritical Care and Intensive Care MedicineCoronary AngiographyMicrocirculationTakotsubo CardiomyopathyInternal medicinemedicine.arteryCoronary CirculationMedicineHumansAgedbusiness.industryMicrocirculationmedicine.diseaseStenosisAnesthesiology and Pain Medicinemedicine.anatomical_structureRight coronary arteryCardiologyRadiographic Image Interpretation Computer-AssistedFemalebusinessTIMIBlood Flow VelocityArteryJournal of clinical monitoring and computing
researchProduct

Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis

2013

We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid-structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s(2)) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m(2)) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in t…

Malemedicine.medical_treatmentHemodynamicsAorta ThoracicMedicineThoracic aortaHematomamedicine.diagnostic_testEndovascular ProceduresModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeAnatomyTreatment OutcomeAtherosclerosiCardiologyWall shear streCardiology and Cardiovascular MedicineBrief CommunicationsBlood Flow VelocityHumanPulmonary and Respiratory Medicinemedicine.medical_specialtyAortographyAortic RuptureAortic DiseasesAortographyBlood Vessel Prosthesis ImplantationSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchinePenetrating atherosclerotic ulcerPenetrating atherosclerotic ulcerInternal medicinemedicine.arteryFluid-structure interactionShear stressHumansArterial PressureComputer SimulationHemodynamicAortic ruptureUlcerAgedEndovascular Procedurebusiness.industryHemodynamicsStentmedicine.diseaseAtherosclerosisAortic DiseaseBlood pressureRegional Blood FlowSurgeryStress MechanicalbusinessTomography X-Ray Computed
researchProduct

Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents

2020

Recently, multilayer stents for type B aortic dissections (TBAD) have been proposed to decrease false lumen flow, increase and streamline true lumen flow, and retain branch vessel patency. We aimed to provide a protocol with standardized techniques to investigate aortic remodeling of TBAD by multilayer flow modulators (MFM) in static geometric and hemodynamic analyses. Combining existing literature and new insights, a standardized protocol was designed. Using pre- and postoperative CT scans, geometric models were constructed, lumen dimensions were calculated, computational fluid dynamics (CFD) models were composed, and velocity and pressures were calculated. Sixteen TBAD cases treated with …

Materials scienceGeometric analysisHemodynamics3d modelcomputational fluid dynamics030204 cardiovascular system & hematologylcsh:TechnologyArticle03 medical and health sciences0302 clinical medicinemedicineMedical imagingGeneral Materials Scienceaortic dissectionlcsh:Microscopylcsh:QC120-168.85Aortic dissectionlcsh:QH201-278.5multilayer flow modulatorlcsh:Tmedicine.diseaseaortic remodelinggeometric analysisLumen DiameterFlow velocitylcsh:TA1-2040lcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringlcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971030217 neurology & neurosurgeryBiomedical engineeringLumen (unit)Materials
researchProduct

Can biomechanical analysis shed some light on aneurysmal pathophysiology? Preliminary study on ex vivo cerebral arterial walls

2019

Abstract Background The pathophysiology of cerebral aneurysm is complex and poorly understood, and it can have the most catastrophic clinical presentation. Flow dynamics is a key player in the initiation and progression of aneurysm. Better understanding the interaction between hemodynamic loading and biomechanical wall responses can help to add the missing piece on aneurysmal pathophysiology. In this laboratory study we aimed to analyze the effect of the application of a mechanical force to cerebral arterial walls. Methods Displacement control tests were performed on five porcine cerebral arteries. The test machine was the T150 Nanotensile. The stiffness variation with the increment of the …

Materials scienceSwineCerebral arteriesBiophysicsHemodynamicsStrain (injury)Weight-BearingStress (mechanics)03 medical and health sciences0302 clinical medicineAneurysmmedicineAnimalsHumansOrthopedics and Sports MedicineAortaMechanical PhenomenaHemodynamicsStiffnessIntracranial AneurysmArteries030229 sport sciencesmedicine.diseaseBiomechanical analysis Flow dynamics Cerebral aneurysm Cerebral arterial wallsPathophysiologyBiomechanical PhenomenaHyperelastic materialAnisotropyStress Mechanicalmedicine.symptom030217 neurology & neurosurgeryBiomedical engineering
researchProduct

Investigation of the hemodynamic flow conditions and blood-induced stresses inside an abdominal aortic aneurysm by means of a SPH numerical model.

2019

The estimation of blood flow-induced loads occurring on the artery wall is affected by uncertainties hidden in the complex interaction of the pulsatile flow, the mechanical parameters of the artery, and the external support conditions. To circumvent these difficulties, a specific tool is developed by combining the aorta displacements measured by an electrocardiogram-gated-computed tomography angiography, with the blood velocity field computed by a smoothed particle hydrodynamics (SPH) numerical model. In the present work, the SPH model has been specifically adapted to the solution of the 3D Navier-Stokes equations inside a domain with boundaries of prescribed motion. Images of the abdominal…

Materials scienceTime FactorsQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsBiomedical EngineeringPulsatile flowHemodynamicsSettore ICAR/01 - IdraulicaPhysics::Fluid DynamicsAneurysmDiastolemedicine.arterymedicineShear stressPressureHumansComputer SimulationMolecular BiologyAortamedicine.diagnostic_testCardiac cycleApplied MathematicsHemodynamicsModels CardiovascularMechanicsmedicine.diseaseAbdominal aortic aneurysmBiomechanical PhenomenaComputational Theory and MathematicsModeling and SimulationAngiographycardiovascular systemHydrodynamicsStress MechanicalInfrarenal abdominal aorta aneurysm shear stresses arterial wall SPH moving boundarySoftwareAlgorithmsBlood Flow VelocityAortic Aneurysm AbdominalInternational journal for numerical methods in biomedical engineeringREFERENCES
researchProduct