Search results for "Hemodynamics"
showing 10 items of 511 documents
Impact of Thoracic Endografting on the Hemodynamics of the Native Aorta: Pre- and Postoperative Assessments of Wall Shear Stress and Vorticity Using …
2021
Purpose To quantify the hemodynamic consequences of thoracic endovascular aortic repair (TEVAR) by comparing the preoperative and postoperative wall shear stress (WSS) and vorticity profiles on computational fluid dynamics (CFD) simulations. Materials and Methods The pre- and postoperative computed tomography (CT) scans from 20 consecutive patients (median age 69 years, range 20–87) treated for different thoracic aortic pathologies (11 aneurysms, 5 false aneurysms, 3 penetrating ulcers, and 1 traumatic aortic rupture) were segmented to construct patient-specific CFD models using a meshless code. The simulations were run over the cardiac cycle, and the WSS and vorticity values measured at th…
Microalbuminuria fractional clearance and early renal permselectivity changes in essential hypertension.
1992
In order to verify if, in essential hypertension (EH), the microalbuminuria (AER) increase could be due to hemodynamic modifications or to glomerular structural changes, in 15 essential hypertensives (EHs) with 24-hour AER16 micrograms/min and in 15 EHs with 24-hour AERor = 16 micrograms/min, the day- and nighttime behavior of creatinine clearance (Ccr), as well as AER clearance (AER-C) and fractional clearance (AER-FC), and behavior of blood pressure (BP) was evaluated. Patients with 24-hour AER16 micrograms/min showed significantly higher values of 24-hour and daytime Ccr than the other group of EHs, while during the night period, there were no significant differences between the two grou…
2020
Motor control is associated with suppression of oscillatory activity in alpha (8–12 Hz) and beta (12–30 Hz) ranges and elevation of oxygenated hemoglobin levels in motor-cortical areas. Aging leads to changes in oscillatory and hemodynamic brain activity and impairments in motor control. However, the relationship between age-related changes in motor control and brain activity is not yet fully understood. Therefore, this study aimed to investigate age-related and task-complexity-related changes in grip force control and the underlying oscillatory and hemodynamic activity. Sixteen younger [age (mean ± SD) = 25.4 ± 1.9, 20–30 years] and 16 older (age = 56.7 ± 4.7, 50–70 years) healthy men were…
Application of C1-Esterase Inhibitor During Reperfusion of Ischemic Myocardium
2001
Background—Complement activation during reperfusion of ischemic myocardium augments myocardial injury, and complement inhibition with C1-esterase inhibitor (C1-INH) at the time of reperfusion exerts marked cardioprotective effects in experimental studies. Application of C1-INH in newborns, however, was recently reported to have dangerous and even lethal side effects. This study addresses the essential role of dosage in studies using C1-INH.Methods and Results—Cardioprotection by C1-INH was examined in a pig model with 60 minutes of coronary occlusion followed by 120 minutes of reperfusion. C1-INH was administered intravenously 5 to 10 minutes before coronary reperfusion without heparin at a…
Influence of dopexamine on hemodynamics, intramucosal pH, and regulators of the macrocirculation and microcirculation in patients undergoing abdomina…
2000
Abstract Objective: To investigate whether dopexamine hydrochloride beneficially influences splanchnic perfusion and regulators of the macrocirculation and microcirculation in patients undergoing surgery of the abdominal aorta. Design: Prospective, blinded, and randomized study. Setting: University-affiliated hospital. Participants: Twenty patients undergoing elective abdominal aortic surgery. Interventions: The patients were randomized to one of two groups. In the dopexamine group (DOP, n = 10), dopexamine, 1 μg/kg/min, was started before surgery and continued for 24 hours. In the control group (COG, n = 10), patients received saline solution as placebo. Extensive hemodynamic monitoring wa…
Aortic stiffness in patients with early sepsis
2014
Acute and chronic systemic inflammatory conditions are associated with aortic stiffening. Carotid-femoral pulse wave velocity (PWV), a marker of aortic stiffness, increases in patients with inflammatory diseases and independently correlates to levels of C-reactive protein (CRP). The effects of massive inflammatory response in early sepsis on mechanical properties of the aorta have not been investigated. The objective of the current study was to prospectively assess aortic stiffness in patients with early severe sepsis and septic shock and relate it to inflammatory and haemodynamic variables and outcome.
Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse
2011
OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…
An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.
2015
Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…
Framework for Fluid-Structure Interaction Analysis of Aortic Coarctation Resulting From Proximal Protusion of Thoracic Aortic Stent Graft Into the Ar…
2011
Thoracic aortic stent grafts (TASG) are commonly used to repair aortic anomalies or diseases in a minimally-invasive fashion. One complication of TASG is collapse, whereby blood is unable to completely flow through the graft as intended. Most TASG collapses occur in the setting of endovascular repair of traumatic thoracic aortic transection, where a typically smaller diameter aorta of pediatric patients is repaired with a relatively larger diameter endograft designed to treat aneurysmal disease [1]. It is hypothesized that the poor apposition of the leading edge of the proximal stent graft to the lesser curvature of the aortic arch can result increased hemodynamic force at the leading side …
Reference values of fetal aortic flow velocity waveforms and associated intra-observer reliability in normal pregnancies
2001
Objectives It was the aim of the present study to calculate new Doppler reference ranges for blood flow velocities (Vmax, Vmean, Vmin) and resistance indices (PI, RI) for the fetal descending aorta by automatic waveform analysis. Design Cross-sectional prospective study. Subjects Nine hundred and twenty-six low-risk pregnancies at 18–41 weeks' gestation. Methods Aortic blood flow velocities were derived with pulsed-wave color Doppler. Measurements were carried out at the level of the diaphragm. Reference ranges for the individual measuring parameters were constructed based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square pri…