Predictors of short‐ and long‐term outcomes of patients undergoing transcatheter mitral valve edge‐to‐edge repair
2020
Objectives Transcatheter mitral valve repair (TMVR) by edge-to-edge therapy is an established treatment for severe mitral valve regurgitation (MR). Background Symptomatic and prognostic benefit in functional MR has been shown recently; nevertheless, data on long-term outcomes are sparse. Methods and results We analyzed survival of patients treated with isolated edge-to-edge repair from June 2010 to March 2018 (primarily combined edge-to-edge repair with other mitral valve interventions was excluded) in a retrospective monocentric study. Overall, 627 consecutive patients (47.0% females, 78.6 years in mean) were included. Leading etiology was functional MR (57.4%). Follow-up regarding surviva…
Speech perception outcomes after cochlear implantation in prelingually deaf infants: The Western Sicily experience
2013
Objectives: To describe audiometric characteristics and speech perception performances of prelingually deaf Sicilian children after cochlear implantation; to identify the influence of cochlear implant (CI) user and family's characteristics on speech recognition and intelligibility outcomes. Methods: Twenty-eight infants with a congenital or acquired hearing impairment and implanted before the 3rd year of life were studied; all children suffered from bilateral sensorineural hearing loss (SNHL) with evidence of lack of hearing aids benefit and no evidence of intellectual disability. The study of the main characteristics associated with CI user and family's profile was performed with a clinica…
Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.
2011
Objectives The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients. Materials and methods In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer ac…
Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.
2019
To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…
Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management
2019
Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…
Functional Rehabilitation of Mandibular Continuity Defects Using Autologous Bone and Dental Implants – Prognostic Value of Bone Origin, Radiation The…
2008
<i>Aim:</i> The aim of this retrospective study was to investigate prognostic parameters for the rehabilitation of mandibular continuity defects with free autologous bone and dental implants for patients after intraoral squamous cell carcinoma. <i>Methods:</i> Following potential prognostic factors for implant survival were analyzed: bony bed (local bone versus augmented iliac crest bone), radiation dose (no radiation, <50 Gy, ≥50 Gy) and implant dimensions. Kaplan-Meier survival estimates of the inserted implants were performed. <i>Results:</i> After 5 years, the cumulative survival rate of all investigated implants was 82.6%. Dental implantation into…
Differential metabolic profiling of non-pure trisomy 21 human preimplantation embryos.
2012
Objective To investigate the metabolomic signature of trisomy 21 preimplantation human embryos by a noninvasive approach using mass spectrometry– (MS-) and nuclear magnetic resonance spectroscopy– (NMR-) based metabolic profiling platforms. Design A total of 171 spent media samples were collected from day 3 embryos and comparatively analyzed by MS analysis (chromosomally normal embryos, n=15; trisomy 21 embryos, n=15) and a matched control media group (without embryo, n=14) and by NMR spectroscopy (normal embryos, n=39; trisomy 21 embryos, n=35; monosomy 21 embryos, n=24) and a matched control media group (without embryo, n=29). Setting IVF clinic/preimplantation genetic diagnosis (PGD) uni…
Knowledge, aptitudes, and preferences in implant dentistry teaching/training among undergraduate dental students at the University of Barcelona
2017
Background Oral implant rehabilitation should be considered a treatment option for any edentulous patient and Implant Dentistry is currently a discipline taught in the undergraduate formation. The level of knowledge acquired and how the students perceive the quality of training in Implant Dentistry could assess to know if it is necessary to improve the syllabus. Material and Methods A questionnaire was developed with 11 questions: Basic knowledge (7); Perception of training received (2); Ways in which students would receive training (2). To be responded anonymously and voluntarily for undergraduates students in the Faculty of Dentistry (University of Barcelona, Spain). Results One hundred a…
Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement su…
2013
Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified …
Drilling dimension effects in early stages of osseointegration and implant stability in a canine model
2015
Background: This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Material and Methods: Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linea…