Search results for "IMPLANTATION"

showing 10 items of 733 documents

Stress distribution in fixed mandibular prostheses fabricated by CAD/CAM and conventional techniques: Photoelastic and strain gauge analyses

2019

Made available in DSpace on 2020-12-12T00:55:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-09-01 The aim of this study was to evaluate the distribution of stress in complete fixed mandibular prostheses with infrastructures (IE) fabricated with different materials and techniques, under compressive force. A model of an edentulous mandible, which received five 4x11 mm external hexagon implants between the mental foramens, was fabricated. The groups were divided into: Group I - IE in nickel-chromium with an acrylic resin occlusal coating; Group II - IE in nickel-chromium with a ceramic occlusal coating; Group III - IE milled in zirconia with a ceramic coating. For the photoelastic m…

OrthodonticsProsthetic DentistryMaterials scienceResearchDental implantsBiomechanicsengineering.material:CIENCIAS MÉDICAS [UNESCO]Compression (physics)Stress (mechanics)Mandibular prosthesis implantationCompressive strengthCoatingvisual_artUNESCO::CIENCIAS MÉDICASengineeringTukey's range testvisual_art.visual_art_mediumBiomechanicsGeneral DentistryAcrylic resinStrain gaugeJournal of Clinical and Experimental Dentistry
researchProduct

ALLOGENEIC BONE GRAFTING MATERIALS – UPDATE OF THE CURRENT SCIENTIFIC STATUS

2017

Worldwide population aging and associated with it epidemics of osteoporosis, widespread of bone and joint reconstructive surgery and first of all joint replacement lead to explosive growth of interest in bone grafting.Although autografts are still the golden standard in bone regeneration, allogeneic bone substitutes have reached a state that allows for their application with satisfying clinical results. However, it has repeatedly been supposed that the different allogeneic materials underwent different purification processes, which modifies bone regeneration properties of these materials and also for different safety conditions. In the present publication, the treatment of the precursor tis…

Orthopedic surgerymedicine.medical_specialtybone graftingbusiness.industryJoint replacementRegeneration (biology)medicine.medical_treatmentOsteoporosisImplantation SiteBone graftingbone tissue regenerationmedicine.diseaseBone remodelingSurgeryallogeneic bone substitutemedicineAutogenous boneBone regenerationbusinessRD701-811Traumatology and Orthopedics of Russia
researchProduct

Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation p…

2016

Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established. We compared different level of oversizing in our cohort of con- secutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. Methods From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien® or Corevalve devices®. Retrospectively, according to pre-procedural MSCT and the valve size, pa- tients were classified into thr…

OversizingTranscatheter aortic valve implantationAortic regurgitation; Aortic valve stenosis; Multislice-CT; Oversizing; Transcatheter aortic valve implantationSymposium: Transcatheter aortic valve implantationAortic valve stenosiAortic regurgitationAortic valve stenosisMultislice-CT
researchProduct

Unpredicted ovulations and conceptions during early pregnancy: an explanatory mechanism of human superfetation

2012

In this bioessay, a literature review on human superfetation was performed in order to find epidemiological variables associated with this phenomenon. Thereafter, an explanatory mechanism of superfetation compatible with the endocrinological, histological and physiological changes undergone by women during early pregnancy is proposed. Superfetation can be defined as the ovulation, fertilisation and implantation of a second or additional embryo(s) during pregnancy. The literature review evidences a small discordance in gestational age between dizygotic twins in humans (range: 2–4 weeks; mean ± s.e.m.: 3.3 ± 0.3 weeks). This difference is compatible with a luteal out-of-phase (LOOP; i.e. atyp…

Ovulationmedia_common.quotation_subjectTwinsPhysiologyGestational AgeSuperfetationReproductive technologyLuteal PhaseLuteal phaseBiologyEndocrinologyOvarian FolliclePregnancyDeciduaTwins DizygoticGeneticsmedicineHumansEmbryo ImplantationSuperfetationMolecular BiologyOvulationmedia_commonPregnancyEstradiolGestational ageAnatomymedicine.diseaseDecidual reactionmedicine.anatomical_structureReproductive MedicineFertilizationFemaleAnimal Science and ZoologyPregnancy MultipleDevelopmental BiologyBiotechnologyFallopian tubeReproduction, Fertility and Development
researchProduct

Sputtered cuprous oxide thin films and nitrogen doping by ion implantation

2016

Abstract The structural, optical and electrical properties of sputtered cuprous oxide thin films have been optimized through post-deposition thermal treatments. Moreover we have studied the effects of nitrogen doping introduced by ion implantation followed by the optimized oxidant thermal annealing. Three concentrations have been used, 0.6 N%, 1.2 N%, and 2.5 N%. Along with the preservation of the Cu 2 O phase, a slight optical band gap narrowing and a significant conductivity enhancement has been observed with respect to the undoped samples. These results can be justified by the absence of further oxygen vacancies promoted by dopant introduction and by the substitution of O atoms by N ones…

OxidantPostimplantation annealingLattice configurationMaterials scienceBand gapAnnealing (metallurgy)NitrogenInorganic chemistryOxidePhotovoltaic application02 engineering and technology01 natural sciencesOxygen vacancieSettore ING-INF/01 - ElettronicaSettore FIS/03 - Fisica Della Materiachemistry.chemical_compoundSputtering0103 physical sciencesMaterials ChemistryDopingSemiconductor dopingConductivity enhancementDoping (additives)Thin filmIonDepositionOxide film010302 applied physicsDopantDopingMetals and AlloysSputteringSurfaces and Interfaces021001 nanoscience & nanotechnologyOut of equilibriumSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsEnergy gapOptical and electrical propertieIon implantationchemistryIon implantationThermal-annealing0210 nano-technologyCopperCuprous oxide
researchProduct

Apoptosis rate of cumulus cells can be considered as an indicator for the selection of embryos to improve ongoing pregnancy and implantation rates.

2014

Cumulus cells apoptosis rate an adjunct to morphology evaluation for the embryo selection on day 3 could be considered a new tool, compared with embryo selection by morphology alone, to select the embryos with higher implantation potential to increase the clinical outcomes after ICSI. Several studies have demonstrated a lower cumulus cell apoptotic rates in women who achieved pregnancy compared with women who did not become pregnant after ICSI. A prospective randomized observational study on 76 ICSI patients was performed before Ovum Pick-Up. Patients were randomized into either the control group (embryo selection by morphology only, A group: 48 patients) or the treatment group (morphology …

PMA cumulus cells apoptosis rate implantation potentialSettore BIO/06 - Anatomia Comparata E Citologia
researchProduct

Ahmed valve, suture-less implantation: A new approach to an easier technique.

2013

Purpose Tissue adhesives have been used in ophthalmology instead of sutures to minimize the operating time. This case series investigated the effectiveness and safety of use of cyanoacrylate in Ahmed valve implantation through pars plana for refractory glaucoma. Patients and methods Seventeen eyes of 17 patients with refractory glaucoma underwent Ahmed valve scleral suture-less implantation through pars plana with a cyanoacrylate suture of the plate. Refractory glaucoma was defined as intraocular pressure (IOP) ≥ 21 mm Hg with antiglaucoma eye drops, good adherence to treatment, and no previous glaucoma surgery. IOP control and development of complications were evaluated during the follow-u…

Pars planaAdultMalemedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresAnterior Chambermedicine.medical_treatmentGlaucomaVitrectomyPilot ProjectsProsthesis ImplantationTonometry OcularPostoperative ComplicationsOphthalmologymedicineGlaucoma surgeryHumansCyanoacrylatesProspective StudiesGlaucoma Drainage ImplantsHyphemaIntraocular PressureAgedAged 80 and overbusiness.industrySuture TechniquesRetinal detachmentGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structureTreatment OutcomeVitreous hemorrhageFemalesense organsbusinessJournal of glaucoma
researchProduct

Surface passivation of gallium selenide by nitrogen implantation

2002

In this paper we report on the characterization of nitrogen-implanted single-crystal GaSe samples. Nitrogen atoms were implanted at 80 keV, with doses ranging from 4 × 10 13 to 10 15 N + ions cm -2 . Next, samples were aged in open air and characterized by small-area XPS, together with an unimplanted clean surface, in order to quantify the effects of the nitrogen implantation. In general, we found that the oxidation was fully prevented in N + -implanted samples.

PassivationGallium selenideInorganic chemistrychemistry.chemical_elementSurfaces and InterfacesGeneral ChemistryCondensed Matter PhysicsNitrogenSurfaces Coatings and FilmsIonIon implantationchemistryX-ray photoelectron spectroscopyMaterials ChemistrySurface structureOpen airSurface and Interface Analysis
researchProduct

A suspicious calcium spike.

2015

Pathologymedicine.medical_specialtychemistry.chemical_elementCalciumAortographySeverity of Illness IndexPredictive Value of TestsRisk FactorsMedicineHumansProsthetic valveAged 80 and overHeart Valve Prosthesis Implantationbusiness.industryCalcinosisAortic Valve StenosisTomography x ray computedchemistryHeart InjuriesAortic ValveHeart Valve ProsthesisSpike (software development)FemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedEuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
researchProduct

Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients

2016

The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.

Phakic Intraocular Lensesmedicine.medical_specialtyKeratoconusgenetic structuresKeratoconusPhakic intraocular lens03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineLenses Intraocularbusiness.industryfungifood and beveragesRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyQuality of vision030221 ophthalmology & optometryOptometrySurgerysense organsbusiness030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct