Search results for "INJECTION"
showing 10 items of 920 documents
Regulation of IgE production and airway reactivity by CD4(-)CD8(-) regulatory T cells
2015
The mechanisms of tolerance induction occurring in the course of allergen-specific immunotherapy have not been elucidated in full detail. Our study aimed to characterize high zone tolerance in mouse models of type I allergy and of allergic airway inflammation induced by subcutaneous sensitization of mice with high doses of the model allergen ovalbumin (OVA) without the use of adjuvant. Mice were immunized by subcutaneous injection of high doses (HD) of OVA or, for comparison, low doses (LD) of OVA in saline. HD-mice showed lower specific IgE, but augmented IgG in sera than LD-mice. Pre-treatment of mice with HD-OVA antigen-specifically inhibited IgE production subsequently induced by LD-OVA…
An alternative allergen:adjuvant formulation potentiates the immunogenicity and reduces allergenicity of a novel subcutaneous immunotherapy product f…
2012
Background Subcutaneous specific immunotherapy (SCIT) has proven sustained clinical efficacy against allergy. The recommended regimen for SCIT is a gradual updosing over a period of weeks. Commonly, in commercial products for SCIT, the specific allergen is formulated with an adjuvant, most often in the form of aluminium hydroxide (AlOH). It has been shown that allergen-specific IgG antibodies are induced as a result of successful SIT. Objective To investigate the possibility of optimizing the formulation of AlOH-based grass-pollen allergy vaccines for SCIT in a way that allows for shorter updosing regimens while maintaining the immunogenicity of the vaccine. Methods Mice were immunized with…
Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly
2001
The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10–800 μg l−1 of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput …
Safety profile of the interleukin-1 inhibitors anakinra and canakinumab in real life clinical practice: a nationwide multicenter retrospective observ…
2018
A few studies have reported the safety profile of interleukin (IL)-1 blockers from real life. The aim of this study is to describe anakinra (ANA) and canakinumab (CAN) safety profile in children and adults, based on data from a real-life setting. Demographic, clinical, and therapeutic data from patients treated with ANA and CAN were retrospectively collected and analyzed. Four hundred and seventy five patients were enrolled; ANA and CAN were prescribed in 421 and 105 treatment courses, respectively. During a mean follow-up of 24.39 ± 27.04 months, 89 adverse events (AE) were recorded; 13 (14.61%) were classified as serious AE (sAE). The overall estimated rate of AE and sAE was 8.4 per 100 p…
Spectrophotometric determination of promazine with an oxidative column in FIA manifolds
1992
Abstract A simple flow-injection spectrophotometric method for the determination of promazine is described. The two proposed procedures are based on the oxidation of analyte with a manganese dioxide column. Concentrations of promazine in the ranges 2–20 and 1–6 are determined with a relative standard deviation of 1.0%. The injection rates are 62 and 80 samples h −1 , respectively. The influence of foreign species and the determination of promazine in a pharmaceutical formulation are also reported.
Flow-injection spectrofluorimetric determination of paracetamol
1990
Abstract A flow-injection spectrofluorimetric determination of paracetamol is reported, based on the oxidation of the analyte with potassium hexacyanoferrate(III) immobilized on an anion-exchange resin, the fluorescence being enhanced with N,N′-dimethylformamide. Concentrations of paracetamol in the range 0.04–17.60 mg l−1 are determined with a relative standard deviation of 1.5%. The injection rate is 25 samples h−1. The influence of foreign species and the determination of paracetamol in several pharamaceutical formulations are also reported.
Micellar liquid chromatography determination of rivaroxaban in plasma and urine. Validation and theoretical aspects.
2019
A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M – 1-propanol 12.5%, phosphate buffered at pH 7) and 20 μL directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in <6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05–5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (−11.1 to 4.2…
Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.
2007
The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…
Optimization of selenium determination in human milk and whole blood by flow injection hydride atomic absorption spectrometry.
1998
abstract A flow injection hydride atomic absorption spectrometry (FI-HAAS) method was developed for determining selenium in human milk and whole blood after microwave digestion of the sample. The sample (2 mL human milk or 0.25 mL blood) was introduced into the microwave vessel with 1.5 mL HN03 and 0.25 mL H202 and 300 W (4 min) and 600 W (4 min) were applied. The digestion was completed by heating to 140 C (2-3 h). Se (VI) was reduced to Se (IV) with hydrochloric acid. The instrumental conditions for FI-HAAS (concentrations of reducing agent and carrier acid, flow rate of argon carrier gas, and sample volume injected) were optimized. The detection limit of the proposed method was 0.23 ng/m…
Peritoneal Cavity is a Route for Gut-Derived Microbial Signals to Promote Autoimmunity in Non-Obese Diabetic Mice
2015
Macrophages play a crucial role in innate immune reactions, and peritoneal macrophages (PMs) guard the sterility of this compartment mainly against microbial threat from the gut. Type 1 diabetes (T1D) is an autoimmune disease in which gut microbiota and gut immune system appear to contribute to disease pathogenesis. We have recently reported elevated free radical production and increased permeability of gut epithelium in non-obese diabetic (NOD) mice. Impaired barrier function could lead to bacterial leakage to the peritoneal cavity. To explore the consequences of impaired gut barrier function on extra-intestinal immune regulation, we characterized peritoneal lavage cells from young newly w…