Search results for "INJECTION"

showing 10 items of 920 documents

Physico-chemical stability of eribulin mesylate containing concentrate and ready-to-administer solutions.

2013

Objectives The aim of this study was to determine the stability of commercially available eribulin mesylate containing injection solution as well as diluted ready-to-administer solutions stored under refrigeration or at room temperature. Methods Stability was studied by a novel developed stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) assay with ultraviolet detection (detection wavelength 200 nm). Triplicate test solutions of eribulin mesylate containing injection concentrate (0.5 mg/mL) and with 0.9% sodium chloride solution diluted ready-to-administer preparations (0.205 mg/mL eribulin mesylate in polypropylene (PP) syringes, 0.020 mg/mL eribulin mesyl…

Eribulin MesylateChromatographybusiness.industryReproducibility of ResultsInjection solutionPharmacologyKetonesHigh-performance liquid chromatographyPharmaceutical SolutionsOncologyDrug StabilityMedicinePharmacology (medical)Chemical stabilitybusinessFuransChromatography High Pressure LiquidDrug PackagingJournal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners
researchProduct

The role of crystalline, mobile amorphous and rigid amorphous fractions in the performance of recycled poly (ethylene terephthalate) (PET)

2012

[EN] The action of thermo-mechanical degradation induced by mechanical recycling of poly(ethylene terephthalate) was simulated by successive injection moulding cycles. Degradation reactions provoked chain scissions and a reduction in molar mass mainly driven by the reduction of diethyleneglycol to ethylene glycol units in the flexible domain of the PET backbone, and the formation of -OH terminated species with shorter chain length. The consequent microstructural changes were quantified taking into account a three-fraction model involving crystalline, mobile amorphous (MAF) and rigid amorphous fractions (RAF). A remarkable increase of RAF, to a detriment of MAF was observed, while the percen…

EthyleneSolucions polimèriquesPolymers and PlasticsInjection mouldingDifferential scanning calorimetry (DSC)Crystalline fractionsMechanical propertiesThermo-mechanical degradationchemistry.chemical_compoundDegradationAmorphous materialsPolymer blendsMaterials ChemistryMechanical recyclingRecyclingComposite materialDiethyleneglycolPoly(ethylene terephthalate) (PET)Injection moldingMolar massMechanical featureRecycled poly(ethylene terephthalate)Microstructural changesCondensed Matter PhysicsChain scissionRigid-amorphous fractionMechanics of MaterialsMAQUINAS Y MOTORES TERMICOSPolymer blendMaterials scienceMechanical performanceViscoelasticityEthyleneDifferential scanning calorimetrySegmental dynamicsInfrared analysis (FT-IR)Degradation reactionDifferential scanning calorimetryInjection mouldingPolyethylene terephthalatesEthylene glycolTermoplàsticsCrystalline materialsShorter chainsAmorphous solidchemistryGlass-rubber relaxationProcessing cyclesEthylene glycol
researchProduct

Pharmakologisch-aktive polymere, 18. Körperverteilung und ausscheidungsverhalten von monomerem und polymerem sulfadiazinacrylamid

1979

Sulfadiazinacrylamid was absorbed after oral and intraperitoneal application in rats to a high extent; the absorption from the intraperitoneum was retarded. Glucose treatment delayed the absorption after both application forms. At comparatively high renal and enteral excretion rates the biological half life time of the monomer was estimated to 8 h. A tumouraffinity was not found but there were indications for a preferred storage in the RES. Poly[sulfadiazinacrylamide] was absorbed after intraperitoneal injection to a clear extent, where at the beginning of the treatment under simultaneous glucose load the absorption was delayed. 24 h after injection higher concentrations in metabolic organs…

Excretionchemistry.chemical_compoundMonomerchemistrymedicine.medical_treatmentPolymer chemistryIntraperitoneal injectionmedicineBiological half-lifeAbsorption (skin)Enteral administrationAfter treatmentResorptionDie Makromolekulare Chemie
researchProduct

Catalan words avoiding pairs of length three patterns

2021

Catalan words are particular growth-restricted words counted by the eponymous integer sequence. In this article we consider Catalan words avoiding a pair of patterns of length 3, pursuing the recent initiating work of the first and last authors and of S. Kirgizov where (among other things) the enumeration of Catalan words avoiding a patterns of length 3 is completed. More precisely, we explore systematically the structural properties of the sets of words under consideration and give enumerating results by means of recursive decomposition, constructive bijections or bivariate generating functions with respect to the length and descent number. Some of the obtained enumerating sequences are kn…

FOS: Computer and information sciencesMathematics::CombinatoricsDiscrete Mathematics (cs.DM)General Computer ScienceInteger sequenceBivariate analysisConstructivelanguage.human_languageTheoretical Computer ScienceCombinatorics[MATH.MATH-CO] Mathematics [math]/Combinatorics [math.CO]FOS: MathematicsEnumerationlanguageDiscrete Mathematics and CombinatoricsMathematics - CombinatoricsCatalanCombinatorics (math.CO)Recursive decompositionBijection injection and surjectionMathematicsDescent (mathematics)Computer Science - Discrete Mathematics
researchProduct

Tailored waveform generation in mode-locked fiber lasers by in-cavity pulse shaper

2014

International audience; We numerically show the possibility of pulse shaping in a mode-locked fiber laser by inclusion of an amplitude-phase spectral filter into the laser cavity. Various advanced temporal waveforms are generated, including parabolic, flat-top and triangular pulses.

Femtosecond pulse shaping[PHYS.PHYS.PHYS-OPTICS] Physics [physics]/Physics [physics]/Optics [physics.optics][PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Materials science[ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryPhysics::Optics02 engineering and technologyInjection seederLaser01 natural sciencesPulse shapinglaw.invention010309 optics020210 optoelectronics & photonicsOpticsFiber Bragg gratingMultiphoton intrapulse interference phase scanlawFiber laser0103 physical sciences0202 electrical engineering electronic engineering information engineeringbusinessBandwidth-limited pulse
researchProduct

Pulse shaping in mode-locked fiber lasers by in-cavity spectral filter

2014

International audience; We numerically show the possibility of pulse shaping in a passively mode-locked fiber laser by inclusion of a spectral filter into the laser cavity. Depending on the amplitude transfer function of the filter, we are able to achieve various regimes of advanced temporal waveform generation, including ones featuring bright and dark parabolic-, flat-top-, triangular- and saw-tooth-profiled pulses. The results demonstrate the strong potential of an in-cavity spectral pulse shaper for controlling the dynamics of mode-locked fiber lasers.

Femtosecond pulse shaping[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Materials science[ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryPhysics::Optics02 engineering and technologyInjection seeder01 natural sciencesPulse shapingAtomic and Molecular Physics and Opticslaw.invention010309 optics020210 optoelectronics & photonicsOpticsMode-lockingFiber Bragg gratinglawFiber laserOptical cavity0103 physical sciences0202 electrical engineering electronic engineering information engineeringbusinessBandwidth-limited pulse
researchProduct

Flow-Injection Solid Phase Partial Least-Squares Spectrophotometric Simultaneous Determination of Iron, Nickel and Zinc

2002

A PLS-2 multivariate calibration method has been developed for the simultaneous determination of iron, nickel and zinc in ternary mixtures by solid phase spectrophotometry associated with flow injection analysis. Fe(II), Ni(II) and Zn(II) form color complexes with 1-(2-thiazolylazo)-2-naphthol (TAN), immobilized on a C18 bonded silica support, at pH 6.4. The proposed procedure is based on the different reaction/retention ratios of the studied ions on the solid support. Bilinear spectrophotometric data of the analytes, fixed in the solid support, were recorded in the 400-800 nm wavelength range as a function of time and a partial least squares (PLS-2) algorithm was used to predict results of…

Flow injection analysisAnalytemedicine.diagnostic_testAnalytical chemistrychemistry.chemical_elementGeneral ChemistryZincAbsorbanceNickelchemistrySpectrophotometryPartial least squares regressionmedicineTernary operationJournal of the Brazilian Chemical Society
researchProduct

Fluorimetric determination of captopril by flow injection analysis

1991

A flow injection analysis procedure is proposed for the determination of captopril. The sample solution was directly injected into the carrier-reagent stream which was prepared by a solution of ceric ions in 0.25 M sulfuric acid. The procedure is based on the fluorimetric monitoring of the formed Ce(III). Chemical, FIA, and instrumental parameters were optimized and the procedure is applied to the captopril determination in pharmaceutical formulations with competitive precision and adequate accuracy.

Flow injection analysisAqueous solutionChromatographyChemistryFluorescence spectrometrySulfuric acidCaptoprilDosage formAnalytical ChemistryIonchemistry.chemical_compoundmedicineSpectroscopymedicine.drugMicrochemical Journal
researchProduct

Flow-injection analysis study of the chemiluminescent behaviour of proflavine and acriflavine

2001

Abstract The chemiluminescent behaviour of the amino acridines like acriflavine, and proflavin is reported. Different strong oxidants (potassium permanganate, cerium(IV), hexacyanoferrate(III), hydrogen peroxide in different media) were tested, and potassium permanganate in sulphuric acid medium was selected. The study of the experimental parameters affecting the oxidation and detection was performed with the aid of a FIA assembly. The calibration graph was applied over the range 0.05–12.0 μg ml −1 of acriflavine (regression coefficient 0.9957, and the calculated relative standard deviation (R.S.D., %) was 0.9; LOD 10 ng ml −1 and the sample throughput 48 h −1 . The study of interfering com…

Flow injection analysisCalibration curveInorganic chemistryAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionAcridonechemistry.chemical_compoundPotassium permanganatechemistrylawEnvironmental ChemistryAcriflavineHydrogen peroxideSpectroscopyProflavineChemiluminescenceAnalytica Chimica Acta
researchProduct

Standard addition method in FIA. Comparison between different assemblies

1999

A comparison between the different proposed methods to perform the standard addition in an on-line way (flow injection analysis) is made. The different assemblies (reverse and conventional FIA) and the employed standards in every method are compared. Three analyses were carried out, two of them were analyses of samples of pH indicators (methylorange and chlorophenol red) prepared at an acid pH, while the standards were prepared at a basic pH. The third analysis was the analysis of chloride in different synthetic waters with a perfectly known composition for all the ions present in the samples. Besides a new method to perform the on-line standard addition is proposed, trying to reduce the co…

Flow injection analysisChemistryAnalytical chemistryBiochemistryChlorideAnalytical Chemistrychemistry.chemical_compoundStandard additionReagentmedicineEnvironmental ChemistryChlorophenol redSpectroscopyAnalysis methodmedicine.drugAnalytica Chimica Acta
researchProduct