Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents.
1993
AbstractObjectives. The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome.Background. The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference,Methods. The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area.Results. Analysis was pe…
Predictive value of venous thromboembolism (VTE)-BLEED to predict major bleeding and other adverse events in a practice-based cohort of patients with…
2018
Summary Venous thromboembolism (VTE)‐BLEED, a decision tool for predicting major bleeding during chronic anticoagulation for VTE has not yet been validated in practice‐based conditions. We calculated the prognostic indices of VTE‐BLEED for major bleeding after day 30 and day 90, as well as for recurrent VTE and all‐cause mortality, in 4457 patients enrolled in the international, prospective XALIA study. The median at‐risk time was 190 days (interquartile range 106–360). The crude hazard ratio (HR) for major bleeding after day 30 was 2·6 [95% confidence interval (CI) 1·3–5·2] and the treatment‐adjusted HR was 2·3 (95% CI 1·1–4·5) for VTE‐BLEED high (versus low) risk patients: the correspondi…
Magnetic resonance myelography evaluation of the lumbar spine end plates and intervertebral disks.
2005
Purpose: To evaluate the value of magnetic resonance (MR) myelography in the evaluation of intervertebral disk and end‐plate degenerative changes in the lumbar spine.Material and Methods: Conventional MR and MR myelography examinations were performed in 150 consecutive patients (69 F and 81 M, mean age 45±15 years, range 18–89). Sagittal T1 and T2‐weighted TSE images were compared to MR myelography obtained with a multishot‐TSE‐T2‐weighted sequence (4000/250/fat suppression). Coronal, sagittal, and both oblique MR myelography projections were obtained. Image analysis was carried out independently by two radiologists who categorized lumbar disks into normal, degenerated, or edematous; and ve…
Force in the Achilles Tendon During Walking With Ankle Foot Orthosis
2009
Background Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. Hypothesis Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. Study Design Controlled laboratory study. Methods In 8 subjects, the maximum force and rate of force development in the Achilles tendon were measured with an optic fiber technique, and the activity of the gastrocnemius, soleus, and tibialis anterior muscles was recorded using electromyography. Trial conditions were walking barefoot and wearing an ankle-foot orthoses set in 3 different positi…
Effect of bike-fit in the perception of comfort, fatigue and pain
2016
The aim of this study was to assess the influence of different bike positions on the perception of fatigue, pain and comfort. Twenty cyclists underwent three tests that involved cycling for 45 min at their individual 50% peak aerobic power output while adopting different positions on the bike. Participants performed the cycling tests adopting three positions defined by two parameters (knee flexion angle [20°, 30°, 40°] and trunk flexion angle [35°, 45°, 55°]) in random order. Angles were measured using a 2D motion analysis system during cycling and applying Fonda's correction factor. Perceptions of comfort, fatigue and pain were reported before the end of each test. The combination of 40° k…
Broncalt®, class II medical device, in patients with acute upper airways disease: a survey in clinical practice.
2019
Inflammation is a common pathogenic mechanism involved in many otorhinolaryngological (ORL) disorders. Broncalt® is a class II Medical Device containing: thermal water (Medesano, PR, Italy), hyaluronic acid, and grapefruit seed extract. It has been reported that it exerted a safe and effective anti-inflammatory, washing, and antimicrobial activity by virtue of these components. Therefore, the aim of the current survey, conducted in clinical practice of 84 Italian ORL centers, was to evaluate its safety and efficacy in the treatment of patients with acute upper airways disease. The 3,533 (1,797 males, mean age 43.5 years) patients were evaluated at baseline (T0) and after a 2-week treatment …
Inability of Laplace's law to estimate sub-bandage pressures after applying a compressive bandage: a clinical study
2021
Objective: The aim of the current study was to compare pressures exerted on the lower limb by a high compression bandage as recorded by sub-bandage sensors and those estimated by Laplace's law. The correlation between pressures obtained in each anatomical zone and the corresponding limb perimeters were explored. Method: For the measurement of sub-bandage pressures, four anatomical zones in the lower right limb were determined. Pressures were recorded by nine pneumatic sensors and a PicoPress transducer. A two-layer compression bandage system (UrgoK2, Urgo Group, France) was used for the dressing. Pressures were registered in supine position. Sensor pressures were compared with those estimat…
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…
Analysis of Fifty-Six Cochlear Implant Device Failures
2008
<i>Objective:</i> Our aim was to present a failure analysis after cochlear implant revision surgery in a large series of children and adults and to assess the outcome and audiologic performance. <i>Methods:</i> Fifty-six cochlear implant failures that occurred in 422 devices implanted between 1990 and 2007 at the Department of Otolaryngology, Head and Neck Surgery at the University of Mainz, Germany, were retrospectively analyzed. The causes of failure were reviewed evaluating the individual history, telemetric and intraoperative findings and manufacturer’s investigation reports. <i>Results:</i> We performed 56 surgical revisions in a series of 422 consec…
Reliability of cochlear implants.
2005
Background The long-term reliability of cochlear implants over time is an important issue for patients and cochlear implant teams. The calculation of cumulative survival rates including all hard failures of cochlear implants is suitable to report objectively about cochlear implant reliability. Methods This is a report of 192 cochlear implants from different manufacturers in adults (n = 58) and children (n = 134). Results The overall cumulative implant survival rate was 91.7% for a period of 11 years. The main reasons for hard failures were design errors of the products and direct or indirect trauma to the cochlea implant site (especially in children) with consecutive breaks of the implant b…