Search results for "Image Interpretation"
showing 10 items of 201 documents
Superresolved digital in-line holographic microscopy for high-resolution lensless biological imaging.
2010
Digital in-line holographic microscopy (DIHM) is a modern approach capable of achieving micron-range lateral and depth resolutions in three-dimensional imaging. DIHM in combination with numerical imaging reconstruction uses an extremely simplified setup while retaining the advantages provided by holography with enhanced capabilities derived from algorithmic digital processing. We introduce superresolved DIHM incoming from time and angular multiplexing of the sample spatial frequency information and yielding in the generation of a synthetic aperture (SA). The SA expands the cutoff frequency of the imaging system, allowing submicron resolutions in both transversal and axial directions. The pr…
Robust three-dimensional best-path phase-unwrapping algorithm that avoids singularity loops.
2009
In this paper we propose a novel hybrid three-dimensional phase-unwrapping algorithm, which we refer to here as the three-dimensional best-path avoiding singularity loops (3DBPASL) algorithm. This algorithm combines the advantages and avoids the drawbacks of two well-known 3D phase-unwrapping algorithms, namely, the 3D phase-unwrapping noise-immune technique and the 3D phase-unwrapping best-path technique. The hybrid technique presented here is more robust than its predecessors since it not only follows a discrete unwrapping path depending on a 3D quality map, but it also avoids any singularity loops that may occur in the unwrapping path. Simulation and experimental results have shown that …
Therapy response evaluation of malignant lymphoma in a multicenter study: comparison of manual and semiautomatic measurements in CT.
2014
Purpose: Comparison of manual one-/bi-dimensional measurements versus semi-automatically derived one-/bi-dimensional and volumetric measurements for therapy response evaluation of malignant lymphoma during CT follow-up examinations in a multicenter setting. Materials and Methods: MSCT data sets of patients with malignant lymphoma were evaluated before (baseline) and after two cycles of chemotherapy (follow-up) at radiological centers of five university hospitals. The long axis diameter (LAD), the short axis diameter (SAD) and the bi-dimensional WHO of 307 target lymph nodes were measured manually and semi-automatically using dedicated software. Lymph node volumetry was performed semi-automa…
Qualitative and quantitative evaluation of solitary thyroid nodules with contrast-enhanced ultrasound: initial results
2005
To assess the feasibility of contrast-enhanced ultrasound (CEUS) of the thyroid gland and to evaluate the potential of this method for characterising solitary thyroid nodules.18 patients affected by solitary thyroid nodules (size range: 0.6 to 3.6 cm; mean: 1.8 cm) confirmed by surgery (nine papillary carcinomas, four follicular carcinomas, three hyperplasias, one follicular adenoma and one Plummer’s adenoma) underwent pulse inversion US at low M.I. (0.06 to 0.08) after i.v. injection of a 2.4-mL bolus of SonoVue. Baseline echogenicity and the dynamic enhancement pattern of each nodule, in comparison with adjacent thyroid parenchyma, were assessed. Signal intensity values on grey-scale imag…
[The effect of instrumentation on original apical foramen shape using steel vs niti rotatory: computerized analysis]
2002
BACKGROUND. A fundamental requirement to obtain a correct endodontic preparation depends on the respect, during cleaning and shaping, of the original morphology of the apical foramen, (AF), so that the filling material will form a complete seal. METHODS. In our previous studies, in order to verify if this presumption was respected using rotary NiTi instruments with cutting tip, we instrumented extracted teeth characterised by a different degree of root curvatures. Using a standardized system to replace the sample, the original shape of the apical foramen of each tooth was recorded using a computerised technique and then compared to the shape after instrumentation. The data showed difference…
Color superposition: a new modality for contrast echocardiography.
1987
To improve the estimation of endocardial borders in echocardiography, a technique has been developed to combine images from contrasted and noncontrasted echocardiograms of the same heart-phase using a color superposition mode. This method allows both experienced as well as less experienced examiners to define the endocardial borders more reproducibly and objectively. This is achieved by displaying tissue structures as gray level images while the ventricular cavity is marked selectively by the color display of the contrast material zone. Results of volume estimations of the left ventricle by different examiners using several imaging modes including color superposition display are presented.
Reconstruction of hyperspectral cutaneous data from an artificial neural network-based multispectral imaging system.
2011
International audience; The development of an integrated MultiSpectral Imaging (MSI) system yielding hyperspectral cubes by means of artificial neural networks is described. The MSI system is based on a CCD camera, a rotating wheel bearing a set of seven interference filters, a light source and a computer. The resulting device has been elaborated for in vivo imaging of skin lesions. It provides multispectral images and is coupled with a software reconstructing hyperspectral cubes from multispectral images. Reconstruction is performed by a neural network-based algorithm using heteroassociative memories. The resulting hyperspectral cube provides skin optical reflectance spectral data combined…
Inverse Tone Mapping Based upon Retina Response
2014
International audience; The development of high dynamic range (HDR) display arouses the research of inverse tone mapping methods, which expand dynamic range of the low dynamic range (LDR) image to match that of HDR monitor. This paper proposed a novel physiological approach, which could avoid artifacts occurred in most existing algorithms. Inspired by the property of the human visual system (HVS), this dynamic range expansion scheme performs with a low computational complexity and a limited number of parameters and obtains high-quality HDR results. Comparisons with three recent algorithms in the literature also show that the proposed method reveals more important image details and produces …
Analysis of the angular acceptance of surface plasmon Bragg mirrors
2007
International audience; We analyze an important aspect of the behavior of surface plasmon polariton (SPP) Bragg mirrors: the dependence of the angular acceptance for reflection on the incidence angle. By means of leakage radiation microscopy, both in direct and Fourier space, we observe that the angular acceptance diminishes for increasing incidence angles. This effect, which can considerably affect the design of devices based on these elements, is shown to be the consequence of the decrease of the bandgap width with increasing incidence angle. (c) 2007 Optical Society of America.
Improved Estimation of Cardiac Function Parameters Using a Combination of Independent Automated Segmentation Results in Cardiovascular Magnetic Reson…
2015
International audience; This work aimed at combining different segmentation approaches to produce a robust and accurate segmentation result. Three to five segmentation results of the left ventricle were combined using the STAPLE algorithm and the reliability of the resulting segmentation was evaluated in comparison with the result of each individual segmentation method. This comparison was performed using a supervised approach based on a reference method. Then, we used an unsupervised statistical evaluation, the extended Regression Without Truth (eRWT) that ranks different methods according to their accuracy in estimating a specific bio-marker in a population. The segmentation accuracy was …