Search results for "Image Interpretation"
showing 10 items of 201 documents
Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Mate…
2018
OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5–2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-k…
High definition plus colonoscopy combined with i-scan tone enhancement vs. high definition colonoscopy for colorectal neoplasia: A randomized trial
2014
High definition endoscopy is the accepted standard in colonoscopy. However, an important problem is missed polyps.Our objective was to assess the additional adenoma detection rate between high definition colonoscopy with tone enhancement (digital chromoendoscopy) vs. white light high definition colonoscopy.In this prospective randomized trial patients were included to undergo a tandem colonoscopy. The first exam was a white light colonoscopy with removal of all visualized polyps. The second examination was randomly assigned in a 1:1 ratio as either again white light colonoscopy (Group A) or colonoscopy with tone enhancement (Group B). Primary endpoint was the adenoma detection rate during t…
Solid bone tumors of the spine: Diagnostic performance of apparent diffusion coefficient measured using diffusion-weighted MRI using histology as a r…
2017
Purpose To assess the diagnostic performance of mean apparent diffusion coefficient (mADC) in differentiating benign from malignant bone spine tumors, using histology as a reference standard. Conventional magnetic resonance imaging (MRI) sequences have good reliability in evaluating spinal bone tumors, although some features of benign and malignant cancers may overlap, making the differential diagnosis challenging. Materials and Methods In all, 116 patients (62 males, 54 females; mean age 59.5 ± 14.1) with biopsy-proven spinal bone tumors were studied. Field strength/sequences: 1.5T MR system; T1-weighted turbo spin-echo (repetition time / echo time [TR/TE], 500/13 msec; number of excitatio…
Influence of age and sex on aortic distensibility assessed by MRI in healthy subjects
2010
International audience; Abstract: Magnetic resonance imaging (MRI) is particularly well adapted to the evaluation of aortic distensibility. The calculation of this parameter, based on the change in vessel cross-sectional area per unit change in blood pressure, requires precise delineation of the aortic wall on a series of cine-MR images. Firstly, the study consisted in validating a new automatic method to assess aortic elasticity. Secondly, aortic distensibility was studied for the ascending and descending thoracic aortas in 26 healthy subjects. Two homogeneous groups were available to evaluate the influence of sex and age (with an age limit value of 35 years). The automatic postprocessing …
MRI radiomics-based machine-learning classification of bone chondrosarcoma.
2019
Abstract Purpose To evaluate the diagnostic performance of machine learning for discrimination between low-grade and high-grade cartilaginous bone tumors based on radiomic parameters extracted from unenhanced magnetic resonance imaging (MRI). Methods We retrospectively enrolled 58 patients with histologically-proven low-grade/atypical cartilaginous tumor of the appendicular skeleton (n = 26) or higher-grade chondrosarcoma (n = 32, including 16 appendicular and 16 axial lesions). They were randomly divided into training (n = 42) and test (n = 16) groups for model tuning and testing, respectively. All tumors were manually segmented on T1-weighted and T2-weighted images by drawing bidimensiona…
Hepatocellular carcinoma (HCC) vs. non-HCC: accuracy and reliability of Liver Imaging Reporting and Data System v2018
2019
PURPOSE: The Liver Imaging Reporting and Data System (LI-RADS) was created to standardize the diagnostic criteria for hepatocellular carcinoma (HCC), and has undergone multiple revisions including a recent update in 2018 (v2018). The primary aim of this study was to determine the diagnostic performance and interrater reliability (IRR) of LI-RADS v2018 for distinguishing HCC from non-HCC primary hepatic malignancy in patients ‘at-risk’ for HCC. A secondary aim was to assess the impact of changes introduced in the v2018 diagnostic algorithm. METHODS: This retrospective study combined a 10-year experience of pathologically-proven primary liver malignancies from two large liver transplant cente…
Representation of time intervals in the right posterior parietal cortex: implications for a mental time line
2009
Space and time interact with each other in the cognitive system. Recent studies indicate the posterior parietal cortex (PPC) as the neural correlate of spatial-temporal interactions. We studied whether the contribution of the PPC becomes critical in tasks requiring the performance of spatial computations on time intervals. We adopted an integrated neuropsychological and transcranial magnetic stimulation (rTMS) approach, presenting behavioural timing tasks to both healthy subjects and right-brain-damaged patients with and without evidence of spatial neglect. rTMS of the right PPC of healthy subjects induced a lateralised bias during a task requiring setting the midpoint of a time interval. T…
Diagnostic performance of reformatted isotropic thin-section helical CT images in the detection of superior semicircular canal dehiscence
2017
Purpose The purpose of this article is to assess the diagnostic performance of computed tomography (CT) reformatted images for detection of superior semicircular canal (SSC) dehiscence. Material and methods Forty-two patients, with sound- and/or pressure-induced vestibular symptoms, and 42 control participants underwent helical CT examination with a highly collimated beam (0.5 mm). Reformatted images of the vestibular labyrinth were obtained in the standard axial and coronal planes (group A images), and in a plane parallel and perpendicular to the SSC (group B images). Diagnostic performance obtained by evaluating the group A images alone and the group B images alone was analyzed by using t…
Normal reference values of multilayer longitudinal strain according to age decades in a healthy population: A single-centre experience.
2017
Aims Recent advancements in echocardiographic technology allow to analyse myocardial strain in multiple layers. Little is known about the impact of age on layer-specific longitudinal strain in healthy subjects. The aim of this study was to analyse the influence of age on multilayer longitudinal strain and establish normal reference values of layer-specific strain according to age decades in a healthy population referring to our echo laboratory using 2D speckle-tracking echocardiography with layer-specific software. Methods and results Two-hundred sixty-six healthy, consecutive subjects (mean age = 39.2 ± 17.5 years, women/men = 137/129), free of cardiovascular risk factors, were enrolled. S…
Disturbed structural connectivity is related to inattention and impulsivity in adult attention deficit hyperactivity disorder
2010
Inattention and impulsivity are the most prominent clinical features of attention deficit hyperactivity disorder (ADHD) in adulthood. Structural and functional neuroimaging studies of subjects with ADHD have demonstrated abnormalities in several brain areas, including fronto-striatal and fronto-cerebellar networks. Mostly, these studies were based on volumetric measurements and have been conducted in children. We investigated white matter (WM) integrity and correlation with measures of attention and impulsivity in adult patients with ADHD adopting diffusion tensor imaging (DTI). N = 37 (21 males) never-medicated adult patients with ADHD combined subtype and N = 34 (16 males) healthy control…