Search results for "Image resolution"
showing 10 items of 377 documents
The X-ray Integral Field Unit (X-IFU) for Athena
2014
Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics princi…
Impact of crystal quality, geometry and surface finish for 3D impact position measurements in gamma ray detection systems
2007
We have studied several ways of optimizing the 3D impact position measurements for gamma ray imaging detectors based on continuous monolithic large sized and thick scintillation crystals. The readout of such detectors is performed with position sensitive photo multipliers and with a depth of interaction (DOI) enhanced charge division readout. We have studied the effect of the crystal truncation angle, the reflective covering and the absorption and scattering mean free paths of the crystal. In particular, we have simulated and measured the impact on the energy resolution and the 3D spatial resolution. The results show that by optimization of the accessible crystal parameters we can enhance t…
Enhanced depth of field integral imaging with sensor resolution constraints.
2009
One of the main challenges in integral imaging is to overcome the limited depth of field. Although it is widely assumed that such limitation is mainly imposed by diffraction due to lenslet imaging, we show that the most restricting factor is the pixelated structure of the sensor (CCD). In this context, we demonstrate that by proper reduction of the fill factor of pickup microlenses, the depth of field can be substantially improved with no deterioration of lateral resolution.
Far-field light imaging in the presence of atmospheric turbulence with rotating anti-phase apertures: Theoretical investigation
2017
We investigated the diffraction of far-field light objects in the presence of turbulence formed by an optical system with a rotating anti-phase mask. This mask facilitates to detect the position of faint companion in every direction around the bright companion. In the presence of atmospheric turbulence, diffraction images of distant objects are beyond the diffraction limits, the proposed phase shift mask has a merit to compensate the turbulence results high contrast astronomical imaging under partially coherent light illumination and it is proficient to increase the resolution limits in a Sparrow criterion sense. In this approach, we demonstrated the mask fabrication in laboratory condition…
Resolution enhancement in quantitative phase microscopy
2019
Quantitative phase microscopy (QPM), a technique combining phase imaging and microscopy, enables visualization of the 3D topography in reflective samples, as well as the inner structure or refractive index distribution of transparent and translucent samples. Similar to other imaging modalities, QPM is constrained by the conflict between numerical aperture (NA) and field of view (FOV): an imaging system with a low NA has to be employed to maintain a large FOV. This fact severely limits the resolution in QPM up to 0.82λ/NA, λ being the illumination wavelength. Consequently, finer structures of samples cannot be resolved by using modest NA objectives in QPM. Aimed to that, many approaches, suc…
All-optical super resolved and extended depth of focus imaging with random pinhole array aperture
2008
In this paper, we present a novel approach which allows combining super resolved imaging with extended depth of focus while the result is obtained by all-optical means and no digital processing is required. The presented approach for the super resolved imaging includes attaching a random pinhole array plate to the aperture plane of the imaging system. The energetic efficiency of the system is high and it is much larger than an imaging through a single pinhole which also has extended depth of focus. The super resolving result is obtained by mechanic scanning of the aperture plane with the random plate.
PESIC: An Integrated Front-End for PET Applications
2007
An ASIC front-end has been developed for multi-anode photomultiplier based nuclear imaging devices. Its architecture has been designed to improve resolution and decrease pile-up probability in Positron Emission Tomography systems which employ continuous scintillator crystals. Analog computation elements are isolated from the photomultiplier by means of a current sensitive preamplifier stage. This allows digitally programmable adjustment of every anode gain, also providing better resolution in gamma event position calculation and a shorter front-end deadtime. The preamplifier stage also offers the possibility of using other types of photomultiplier devices such as SiPM. The ASIC architecture…
A Demonstrator for a new Axial PET Concept
2008
In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…
Analysis of the imaging method for assessment of the smile of laser diode bars.
2009
We study imaging systems designed to assess the smile of laser diode bars (LDBs). The magnification matrix is derived from the required sampling period and the geometries of the LDBs and the charge-coupled device (CCD) array. These image-forming systems present in-plane pure translation invariance, but in the case of anamorphic ones, lack in-plane rotation invariance. It is shown that the smile parameters of the image of the LDB are linked with the smile parameters of the LDB by simple mathematical expressions. The spatial resolution of such optical systems is estimated at approximately 1 microm for a mean wavelength of lambda approximately 800 nm. Our results suggest that, with the current…
Shock-cloud interaction in the Vela SNR observed with XMM-Newton
2005
We analyzed an XMM-Newton EPIC observation of a bright knot, named FilD, in the northern rim of the Vela SNR, where the shock has encountered a cloud. The good combination of sensitivity, spectral, and spatial resolution allowed us to describe the internal structure of the observed ISM clouds and to obtain estimates of their temperature, density, O, Ne, and Fe abundances, and of their extension along the line of sight. We also examined the interaction of the shock with the FilD knot and estimated that the time elapsed from the shock impact is about one cloud crushing time. Our analysis allowed us to conclude that the observed X-ray emission is best explained by the propagation of transmitte…