Search results for "Imaging technique"
showing 10 items of 199 documents
The impact of portal vein tumor thrombosis on survival in patients with hepatocellular carcinoma treated with different therapies: A cohort study.
2020
Background Portal vein tumor thrombosis (PVTT) is a frequent complication of hepatocellular carcinoma (HCC), which leads to classification as advanced stage disease (regardless of the degree of PVTT) according to the Barcelona Clinic Liver Cancer Classification. For such patients, systemic therapy is the standard of care. However, in clinical reality, many patients with PVTT undergo different treatments, such as resection, transarterial chemoembolization (TACE), selective internal radiation therapy (SIRT), or best supportive care (BSC). Here we examined whether patients benefited from such alternative therapies, according to the extent of PVTT. Methods This analysis included therapy-naïve …
Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.
2013
Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…
Gamma-ray irradiation tests of CMOS sensors used in imaging techniques
2014
Technologically-enhanced electronic image sensors are used in various fields as diagnostic techniques in medicine or space applications. In the latter case the devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same equipment. In this paper we report the results of gamma-ray irradiation tests on CMOS image sensors simulating the space radiation over a long time period. Gamma-ray irradiation tests were car ried out by means of IGS-3 gamma irradiation facility of Palermo Uni ver sity, based on 60Co sources with dif fer ent ac tiv i ties. To re duce the dose rate and re al ize a nar row gamma-ray beam, a lead-collimation sys tem was pur posely …
Invagination of the Sphenoid Sinus Mucosa after Endoscopic Endonasal Transsphenoidal Approach and Its Significance
2016
Objective To describe the clinical features of invagination of the sphenoid sinus mucosa (ISM) and compare them with other similar cases using a visual analog scale (VAS) to assess the various nasal symptoms and to discuss its clinical significance and means of prevention. Study design Retrospective chart review at a tertiary referral center. Methods Between 2010 and 2015, 8 patients who had undergone EETSA surgery displayed postoperative ISM. The comparison group consisted of 147 patients who underwent the same surgical procedures and were diagnosed with the same diseases. Pre- or postoperative paranasal sinus computed tomography (PNS CT) and VAS were performed and subsequently analyzed. R…
640-Slice CT Measurement of Superior Orbital Fissure as Gateway for Light into the Brain: Statistical Evaluation of Area and Distance.
2016
Objective Our aim was to provide normative data concerning superior orbital fissure area (SOFA), ocular skin and the substantia nigra (D-SS) and orbital fissure and the substantia nigra (D-SOF-S) distances by CT scan in adult Caucasian population. Methods The area of the superior orbital fissure (SOF), the distance between the ocular skin and the substantia nigra and the distance between the superior orbital fissure and the substantia nigra using CT and 3D-CT images. Results Normative data stratified for age and gender were obtained. The data here reported show that some degree of variability in SOFA, D-SS and D-SOF-S measurements can be observed healthy Caucasian subjects. Gender stratifie…
Caliper navigation for craniotomy planning of convexity targets.
2021
Introduction A technique to localize a radiological target on the head convexity fast and with acceptable precision is sufficient for surgeries of superficial intracranial lesions, and of help in the setting of emergency surgery, computer navigation breakdown, limited resources and education. We present a caliper technique based on fundamental geometry, with inexpensive and globally available tools (conventional CT or MRI image viewer, calculator, caliper). Methods The distances of the radiological target from two landmarks (nasion and porus acusticus externus) are assessed with an image viewer and Pythagoras’ theorem. The two distances are then marked around the landmarks onto the head of…
Radiomic analysis reveals DCE-MRI features for prediction of molecular subtypes of breast cancer.
2017
The purpose of this study was to investigate the role of features derived from breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and to incorporated clinical information to predict the molecular subtypes of breast cancer. In particular, 60 breast cancers with the following four molecular subtypes were analyzed: luminal A, luminal B, human epidermal growth factor receptor-2 (HER2)-over-expressing and basal-like. The breast region was segmented and the suspicious tumor was depicted on sequentially scanned MR images from each case. In total, 90 features were obtained, including 88 imaging features related to morphology and texture as well as dynamic features from tumor and …
Liver stiffness measurement by transient elastography predicts early recovery from acute hepatitis
2010
We read with interest the lead article by Castera and Pinzani,1 particularly the comment regarding the role of transient elastography (TE) in the context of acute hepatitis (AH). The assumption that liver stiffness is determined exclusively by hepatic fibrosis has been challenged by evidence that patients with AH can have high values of liver stiffness measurement (LSM) by TE.2 AH is a suitable model for studying the kinetics of LSM, since inflammation and necrosis increase rapidly and sometimes massively, but may revert with equal speed. We evaluated 92 consecutive patients (mean age 41.8±16.3 years, 71.7% males) with symptomatic AH to assess how LSM was influenced by aetiology, and whethe…
Automated classification of focal breast lesions according to S-detect: validation and role as a clinical and teaching tool
2018
Abstract PURPOSE: To assess the diagnostic performance and the potential as a teaching tool of S-detect in the assessment of focal breast lesions. METHODS: 61 patients (age 21-84 years) with benign breast lesions in follow-up or candidate to pathological sampling or with suspicious lesions candidate to biopsy were enrolled. The study was based on a prospective and on a retrospective phase. In the prospective phase, after completion of baseline US by an experienced breast radiologist and S-detect assessment, 5 operators with different experience and dedication to breast radiology performed elastographic exams. In the retrospective phase, the 5 operators performed a retrospective assessment a…
A maChine and deep Learning Approach to predict pulmoNary hyperteNsIon in newbornS with congenital diaphragmatic Hernia (CLANNISH): Protocol for a re…
2021
Introduction Outcome predictions of patients with congenital diaphragmatic hernia (CDH) still have some limitations in the prenatal estimate of postnatal pulmonary hypertension (PH). We propose applying Machine Learning (ML), and Deep Learning (DL) approaches to fetuses and newborns with CDH to develop forecasting models in prenatal epoch, based on the integrated analysis of clinical data, to provide neonatal PH as the first outcome and, possibly: favorable response to fetal endoscopic tracheal occlusion (FETO), need for Extracorporeal Membrane Oxygenation (ECMO), survival to ECMO, and death. Moreover, we plan to produce a (semi)automatic fetus lung segmentation system in Magnetic Resonanc…