Search results for "Inductively coupled plasma mass spectrometry"
showing 10 items of 95 documents
Development of a new method for the separation of vanadium species and chloride interference removal using modified silica capillaries-DIN-ICP-MS
2004
Abstract A new on-line method for the separation of vanadium (IV) and vanadium (V) as well as for the removal of ClO+ mass spectral interference on vanadium determination by quadrupole-ICP-MS has been developed. The sample introduction system consists of a modified fused silica capillary coupled to a direct injection nebuliser (DIN), between the solvent delivery system and the ICP. Fused silica capillaries were treated with different anion and cation exchanger reagents and were tested for the retention of Cl− and the separation of vanadium ions at μg l−1 levels. A suitable strong anion exchanger functional group (3-aminopropyltrimethoxy silane) was selected. Chlorine anions were retained in…
Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser …
2003
Four alternative analytical procedures for the determination of ten important trace impurities (Mg, Cr, Fe, Cu, Zn, Sr, Zr, Cd, Ba, and Pb) in pure alkaline earth fluoride powders were applied using high-resolution inductively coupled plasma mass spectrometry (ICP-MS). Two procedures are based on a wet-chemical microwave digestion with boric acid and quantification by the standard addition technique and isotope dilution mass spectrometry (IDMS), respectively. In addition, analyses are also performed by laser ablation as a direct solid sampling technique applying matrix-matched external calibration as well as isotope dilution of the powdered sample. For most elements good agreement between t…
Development of an isotope dilution laser ablation ICP-MS method for multi-element determination in crude and fuel oil samples
2009
An inductively coupled plasma isotope dilution mass spectrometric (ICP-IDMS) method with direct introduction of the isotope-diluted sample into the plasma by laser ablation was developed for accurate, sensitive, fast, and simultaneous determination of trace metals in different oil samples. Metallo-organic solutions of isotope spikes (50V, 53Cr, 65Cu, 57Fe, 62Ni, 68Zn, 113Cd, 117Sn, and 206Pb) were prepared from corresponding aqueous stock solutions by using liquid–liquid extraction of complexed metal ions in isobutyl methyl ketone. The isotope-diluted sample was absorbed by a cellulose material, which was fixed in a special PTFE holder for ablation, using a laser system with high ablation r…
Simultaneous determinations of zirconium, hafnium, yttrium and lanthanides in seawater according to a co-precipitation technique onto iron-hydroxide.
2013
Very low concentrations (pg mL(-1) or sub-pg mL(-1) level) along with the high salinity are the main problems in determining trace metal contents in seawater. This problem is mainly considered for investigations of naturally occurring YLOID (Y and Lanthanides) and Zr and Hf in order to provide precise and accurate results. The inductively coupled plasma mass spectrometry (ICP-MS), both in high and low resolution, offers many advantages including simultaneous analyses of all elements and their quantitative determination with detection limits of the order of pg mL(-1). However in the analysis of YLOID in seawater, a better determination needs an efficient combination of ICP-MS measurement wit…
Application of stable isotopes and AF4/ICP-SFMS for simultaneous tracing and quantification of iron oxide nanoparticles in a sediment–slurry matrix
2016
One major challenge in nanomaterial analysis, especially in complex environmental matrices, is the unambiguous differentiation between natural and engineered nanomaterials (ENMs). Particularly with regard to the investigation of ENM's/engineered nanoparticle's (ENPs) fate, analytical methods are needed allowing for tracing and sensitive quantification. Several ENPs are metal-based and contain elements being omnipresent in environmental matrices (e.g., Al, Ti, Zn, Fe and non-metal Si) – hence, high background levels of these elements are expected, compromising sensitive detection. In this work we developed successfully a combined approach of stable isotope labeling (tracing) and reverse post…
Determination of arsenic compounds in beverages by high-performance liquid chromatography-inductively coupled plasma mass spectrometry.
2005
Arsenic compounds including arsenous acid (As(III)), arsenic acid (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were separated by high-performance liquid chromatography (HPLC) and detected by inductively coupled plasma mass spectrometry (ICP-MS). A Hamilton PRX-100 anionic-exchange column and a pH 8.5 K(2)HPO(4)/KH(2)PO(4) 5.0x10(-3)molL(-1) mobile phase were used to achieve arsenic speciation. The separation of arsenic species provided peaks of As(III) at 2.75min, DMA at 3.33min, MMA at 5.17min and As(V) at 12.5min. The detection limits, defined as three times the standard deviation of the lowest standard measurements, were found to be 0.2, 0.2, 0.3 and 0.5ngmL(-1) f…
Active alkaline traps to determine acidic-gas ratios in volcanic plumes: Sampling techniques and analytical methods
2014
In situ measurements have been the basis for monitoring volcanic gas emissions for many years and—being complemented by remote sensing techniques—still play an important role to date. Con- cerning in situ techniques for sampling a dilute plume, an increase in accuracy and a reduction of detection limits are still necessary for most gases (e.g., CO2, SO2, HCl, HF, HBr, HI). In this work, the Raschig-Tube tech- nique (RT) is modified and utilized for application on volcanic plumes. The theoretical and experimental absorption properties of the RT and the Drechsel bottle (DB) setups are characterized and both are applied simultaneously to the well-established Filter packs technique (FP) in the …
A novel approach for analysis of oligonucleotide-cisplatin interactions by continuous elution gel electrophoresis coupled to isotope dilution inducti…
2008
In this work we present a novel approach for in vitro studies of cisplatin interactions with 8-mer oligonucleotides. The approach is based on the recently developed coupling of continuous elution gel electrophoresis (GE) to an inductively coupled plasma-sector field mass spectrometer (ICP-SFMS) with the aim of monitoring the interaction process between this cytostatic drug and the nucleotides. In contrast to existing methods, the electrophoretic separation conditions used here allow both the determination of the reaction kinetics in more detail as well as the observation of dominant intermediates. Two different nucleotides sequences have been investigated for comparison purposes, one contai…
The distribution of Rare Earth Elements discriminates the growth substrate of Vitis vinifera L.
2021
Sustainable agricultural, food-related strategies and geographic traceability require understanding of the plant physiological response to stress potentially generated by contaminated soils. Here, we have investigated the effect of contaminated substrate on growth of Vitis vinifera L. plants analysing the distribution of full Rare Earth Elements (REE) spectra in different parts of the plant. Experiments were carried out using pristine plants growing in a handmade substrate (blank experiment) and in REE artificially-enriched soil (spiked experiment). Our results show that both plant mass and REE amount in leaves are not influenced by the substrate enrichment while roots are by one-order of m…
Development of Antioxidant Protein Extracts from Gilthead Sea Bream (Sparus aurata) Side Streams Assisted by Pressurized Liquid Extraction (PLE)
2021
The pressurized liquid extraction (PLE) technique was used, for the first time, to obtain protein extracts with antioxidant activity from side streams (muscle, heads, viscera, skin, and tailfins) of gilthead sea bream (Sparus aurata) in order to give added value to these underutilized matrices. Extraction conditions previously optimized for sea bass (Dicentrarchus labrax) side streams were applied. Protein recovery percentages were 22% (muscle), 33% (heads), 78% (viscera), 24% (skin), and 26% (tailfins), which represented an increase of 1.2–4.5-fold compared to control samples (extraction by stirring). The SDS-PAGE profiles revealed that PLE-assisted extraction influenced protein molecular …