Search results for "Instrument"

showing 10 items of 5652 documents

The first experimental values for the stopping power of 89Y ions in carbon, nickel and gold

2009

Abstract The stopping power values of 89 Y ions in carbon, nickel and gold were measured with accuracy to better than 5% in the energy range from 0.03 to 8.2 MeV/u. The newly developed B-TOF method was used for the measurements. The results are compared with theoretical and semi-empirical predictions. For this ion/absorber combination no prior experimental data are available.

Time of flightNickelRange (particle radiation)chemistryMetallurgyAnalytical chemistrychemistry.chemical_elementStopping power (particle radiation)Condensed Matter PhysicsInstrumentationCarbonSurfaces Coatings and FilmsIonVacuum
researchProduct

Fast k-Space Mapping of Electronic Bands Using Time-of-Flight Based Cathode-Lens Microspectroscopy.

2015

Time of flightOpticsMaterials scienceCathode lensbusiness.industryk-spacebusinessInstrumentationMicroscopy and Microanalysis
researchProduct

A logarithmic multi-parameter model using gas sensor main and cross sensitivities to estimate gas concentrations in a gas mixture for SnO2 gas sensors

2007

Abstract In a metal-oxide semiconductor gas sensor, the sensitivity of the metal-oxide resistance to concentrations of reducing gases in the surrounding atmosphere is known to be related to adsorption and desorption of gas on the redox reactions between the gas and oxygen. Changes in the electric conductance due to these reactions were measured for tin dioxide semiconductor gas sensors. In this study, we propose a model of gas sensor responding behaviour using a relationship between sensor conductance and gas concentrations in a mixture. A least-squares method fit of measured data was applied to determining the values of coefficients. The proposed method uses main and cross sensitivities th…

Tin dioxidebusiness.industryMetals and AlloysAnalytical chemistrychemistry.chemical_elementConductanceCondensed Matter PhysicsOxygenSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialschemistry.chemical_compoundAdsorptionSemiconductorchemistryDesorptionMaterials ChemistryPotentiometric sensorElectrical and Electronic EngineeringbusinessInstrumentationCarbonSensors and Actuators B: Chemical
researchProduct

[The effect of instrumentation on original apical foramen shape using steel vs niti rotatory: computerized analysis]

2002

BACKGROUND. A fundamental requirement to obtain a correct endodontic preparation depends on the respect, during cleaning and shaping, of the original morphology of the apical foramen, (AF), so that the filling material will form a complete seal. METHODS. In our previous studies, in order to verify if this presumption was respected using rotary NiTi instruments with cutting tip, we instrumented extracted teeth characterised by a different degree of root curvatures. Using a standardized system to replace the sample, the original shape of the apical foramen of each tooth was recorded using a computerised technique and then compared to the shape after instrumentation. The data showed difference…

TitaniumTooth ApexSettore MED/28 - Malattie OdontostomatologicheNickelImage Interpretation Computer-AssistedHumansStainless Steelrotary NiTi instruments stainless steel instruments apical foramen shapeRoot Canal PreparationDental Alloys
researchProduct

Digitizing data acquisition and time-of-flight pulse processing for ToF-ERDA

2016

A versatile system to capture and analyze signals from multi channel plate (MCP) based time-of-flight detectors and ionization based energy detectors such as silicon diodes and gas ionization chambers (GIC) is introduced. The system is based on commercial digitizers and custom software. It forms a part of a ToF-ERDA spectrometer, which has to be able to detect recoil atoms of many different species and energies. Compared to the currently used analogue electronics the digitizing system provides comparable time-of-flight resolution and improved hydrogen detection efficiency, while allowing the operation of the spectrometer be studied and optimized after the measurement. The hardware, data acq…

ToF-ERDANuclear and High Energy PhysicsMaterials sciencedata acquisitionPhysics::Instrumentation and DetectorsIon beam analysisAnalytical chemistrytime-of-flight01 natural sciences010305 fluids & plasmasdigitizerOpticsData acquisitionIonization0103 physical sciencesInstrumentationDiodeta114SpectrometerAnalogue electronics010308 nuclear & particles physicsbusiness.industryDetectorTime of flightCustom softwarebusinesstiedonhankinta
researchProduct

Trajectory bending and energy spreading of charged ions in time-of-flight telescopes used for ion beam analysis

2014

Carbon foil time pick-up detectors are widely used in pairs in ion beam applications as time-of-flight detectors. These detectors are suitable for a wide energy range and for all ions but at the lowest energies the tandem effect limits the achievable time of flight and therefore the energy resolution. Tandem effect occurs when an ion passes the first carbon foil of the timing detector and its charge state is changed. As the carbon foil of the first timing detector has often a non-zero voltage the ion can accelerate or decelerate before and after the timing detector. The combination of different charge state properties before and after the carbon foil now induces spread to the measured times…

ToF-ERDANuclear and High Energy PhysicsRange (particle radiation)Ion beam analysista114Ion beamPhysics::Instrumentation and DetectorsChemistryDetectortandem effectIonTime of flightPhysics::Plasma Physicscarbon foilElectric fieldtime-of-flighToF-EAtomic physicsInstrumentationFOIL methodNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Depth profiling of Al2O3 + TiO2 nanolaminates by means of a time-of-flight energy spectrometer

2011

Atomic layer deposition (ALD) is currently a widespread method to grow conformal thin films with a sub-nm thickness control. By using ALD for nanolaminate oxides, it is possible to fine tune the electrical, optical and mechanical properties of thin films. In this study the elemental depth profiles and surface roughnesses were determined for Al2O3 + TiO2 nanolaminates with nominal single-layer thicknesses of 1, 2, 5, 10 and 20 nm and total thickness between 40 nm and 60 nm. The depth profiles were measured by means of a time-of-flight elastic recoil detection analysis (ToF-ERDA) spectrometer recently installed at the University of Jyväskylä. In TOF-E measurements 63Cu, 35Cl, 12C and 4He ions…

ToF-ERDANuclear and High Energy Physicsdepth profilingMaterials scienceSpectrometerta114business.industryAnalytical chemistryERDIonTotal thicknessElastic recoil detectionTime of flightAtomic layer depositionnanolaminateAl2O3 and TiO2ALDOptoelectronicsThin filmbusinessInstrumentationEnergy (signal processing)
researchProduct

A simple timestamping data acquisition system for ToF-ERDA

2015

A new data acquisition system, ToF-DAQ, has been developed for a ToF-ERDA telescope and other ToF-E and ToF-ToF measurement systems. ToF-DAQ combines an analogue electronics front-end to asynchronous time stamped data acquisition by means of a FPGA device. Coincidences are sought solely in software based on the timestamps. Timestamping offers more options for data analysis as coincidence events can be built also in offline analysis. The system utilises a National Instruments R-series FPGA device and a Windows PC as a host computer. Both the FPGA code and the host software were developed using the National Instruments LabVIEW graphical programming environment. Up to eight NIM ADCs can be han…

ToF-ERDANuclear and High Energy Physicsta114ta213Computer sciencebusiness.industryData acquisitionTimestampingSoftwareData acquisitionAsynchronous communicationTimestampingLabVIEWMicrosoft WindowsTimestampbusinessField-programmable gate arrayInstrumentationHost (network)FPGAComputer hardwaretiedonhankintaNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Time-of-flight - Energy spectrometer for elemental depth profiling - Jyväskylä design

2014

Abstract A new time-of-flight elastic recoil detection spectrometer has been built, and initially the main effort was focused in getting good timing resolution and high detection efficiency for light elements. With the ready system, a 154 ps timing resolution was recorded for scattered 4.8 MeV 4 He 2+ ions. The hydrogen detection efficiency was from 80% to 20% for energies from 100 keV to 1 MeV, respectively, and this was achieved by having an additional atomic layer deposited Al 2 O 3 coating on the first timing detector’s carbon foil. The data acquisition system utilizes an FPGA-card to time-stamp every time-of-flight and energy event with 25 ns resolution. The different origins of the ba…

ToF-ERDANuclear and High Energy Physicstiming gateMaterials scienceIon beam analysista114SpectrometerHydrogenbusiness.industryDetectorchemistry.chemical_elementelemental depth profilingion beam analysistime-of-flightElastic recoil detectionTime of flightData acquisitionOpticschemistryCoincidentbusinessInstrumentation
researchProduct

Discrete Tomography Reconstruction Through a New Memetic Algorithm

2008

Discrete tomography is a particular case of computerized tomography that deals with the reconstruction of objects made of just one homogeneous material, where it is sometimes possible to reduce the number of projections to no more than four. Most methods for standard computerized tomography cannot be applied in the former case and ad hoc techniques must be developed to handle so few projections.

Tomographic reconstructionSettore INF/01 - Informaticabusiness.industryBinary imageGenetic algorithmInstrumental noiseMemetic algorithmComputer visionTomographyArtificial intelligenceDiscrete Tomography Memetic Algorithms Evolutionary methods.businessDiscrete tomographyMathematics
researchProduct