Search results for "Instrumentation"
showing 10 items of 4914 documents
Decay pion spectroscopy: a new approach
2019
We propose a new experiment for decay pion spectroscopy of light hypernuclei at electron- and proton-beam facilities, using the recoil distance technique for separation of produced hypernuclei and a magnetic spectrometer for precise measurement of the decay pion momentum. Low-pressure MWPCs are advocated for low-energy recoil detection as they provide position and time information and are highly insensitive to gamma-ray and electron background. The position and timing characteristics of such a recoil detector were studied using ~5 MeV {\alpha}-particles. By using the present proposed approach the rate of the detected hypernuclei can be increased by one-to-two orders of magnitude compared to…
Characterisation of radiation damage in silicon photomultipliers with a Monte Carlo model
2008
Measured response functions and low photon yield spectra of silicon photomultipliers (SiPM) were compared to multi-photoelectron pulse-height distributions generated by a Monte Carlo model. Characteristic parameters for SiPM were derived. The devices were irradiated with 14 MeV electrons at the Mainz microtron MAMI. It is shown that the first noticeable damage consists of an increase in the rate of dark pulses and the loss of uniformity in the pixel gains. Higher radiation doses reduced also the photon detection efficiency. The results are especially relevant for applications of SiPM in fibre detectors at high luminosity experiments.
Development and test of iron-free quadrupole lenses with high magnetic flux densities
2003
Abstract Iron-free magnetic quadrupole lenses have been developed for the focusing of energetic bunched heavy-ion beams. These devices are operated in a pulsed mode and provide very strong magnetic fields. A magnetic flux density of more than 14 T has been reached in a 100 mm long quadrupole with a 20 mm wide aperture, which corresponds to a magnetic flux density of ∼1400 T/m. The pulse duration of the applied electric current is approximately 300 μs with a flat top of several μs. The calculated and measured field properties of the quadrupoles are presented. In a first test experiment with a fast-extracted 650 MeV/u 197 Au 79+ beam (bunch length ∼500 ns) at GSI the focusing properties could…
XENON1T signal from transition neutrino magnetic moments
2020
The recent puzzling results of the XENON1T collaboration at few keV electronic recoils could be due to the scattering of solar neutrinos endowed with finite Majorana transition magnetic moments (TMMs). Within such general formalism, we find that the observed excess in the XENON1T data agrees well with this interpretation. The required TMM strengths lie within the limits set by current experiments, such as Borexino, specially when one takes into account a possible tritium contamination.
Polarimetry on dense samples of spin-polarized 3He by magnetostatic detection
1997
Abstract A very sensitive low-field fluxgate magnetometer is used to detect the static magnetic field produced by dense samples of spin-polarized 3He gas contained in spherical glass cells at pressures around several bars. The 3He nuclear polarization can be extracted with high precision ΔP P by utilizing magnetostatic detection in combination with adiabatic fast-passage spin reversal. The polarization losses can be kept well below 0.1% thus making this type of polarimetry almost non-destructive. More simply even, P can be measured with reduced accuracy by the change of field when the cell is removed from the fluxgate. In this case the accuracy is limited to about 10% due to the uncertainti…
Backings and targets for chemical and nuclear studies of transactinides with TASCA
2008
Abstract At GSI the gas-filled separator TASCA (TransActinide Separator and Chemistry Apparatus) was set up to investigate the chemical and physical properties of the heaviest elements making use of the highest beam intensities available [ www.gsi.de/tasca ; M. Schadel, D. Ackermann, A. Semchenkov, A. Turler, GSI Scientific Report 2005, GSI Report 2006-1, p. 262]. Appropriate backings and targets have to be developed. Conceivable backing materials are aluminium, titanium, and carbon. Aluminium backings and titanium backings in different thickness and from different companies are produced by cold rolling. Deposition by resistance heating is applied for carbon backings. For experiments in a c…
Time-of-flight photoelectron emission microscopy TOF-PEEM: first results
1998
The time structure of the synchrotron radiation at BESSY (Berlin) is used to operate a photoemission electron microscope in a time-of-flight (TOF) mode. The electrons which are emitted from the sample surface with different energies are dispersed in a drift tube subsequent to the imaging optics. The screen of the microscope was replaced by a fast scintillator (tau = 1.4 ns) and the light is detected by an ultra fast gated intensified CCD camera (800 ps gate 1 MHz repetition rate). The resolving power in the energy domain is demonstrated and possible implications on the spatial resolution (chromatic correction) are discussed. Additionally, an improved contrast at very low emission energies i…
Transport of ions in ion guides under flow and diffusion
2000
Abstract A model for ion transport simulations in the ion guide stopping chamber is introduced. Computed transport time distributions are compared to the experimental data obtained in on- and off-line conditions. It is shown that millisecond transport times are feasible and that diffusion of ions is an important mechanism in transport.
ATLAS level-1 calorimeter trigger: subsystem tests of a Jet/Energy-sum Processor module
2003
The ATLAS Level-1 Calorimeter Trigger consists of a Preprocessor, a Cluster Processor (CP), and a Jet/Energy-sum Processor (JEP). The CP and JEP receive digitised trigger-tower data from the Preprocessor and produce trigger multiplicities and total and missing energy for the final trigger decision. The trigger will also provide region-of-interest (RoI) information for the Level-2 trigger and intermediate results of the data acquisition (DAQ) system for monitoring and diagnostics by using readout driver modules (ROD). The Jet/Energy-sum Processor identifies and localises jets, and sums total and missing transverse energy information from the trigger data. The Jet/Energy Module (JEM) is the m…
TRACKING WITH THE ALEPH TIME PROJECTION CHAMBER
1991
The tracking performance of the ALEPH time projection chamber (TPC) has been studied using the data taken during the LEP (Large Electron-Positron Collider) running periods in 1989 and 1990. After careful correction of residual distortions and optimization of coordinate reconstruction algorithms, a single coordinate resolution of 173 mu m in the azimuthal and 740 mu m in the longitudinal direction is achieved. This results in a momentum resolution for the TPC alone of Delta p/p/sup 2/=0.0012 (GeV/c)/sup -1/. In combination with the ALEPH inner tracking chamber (ITC), a total momentum resolution of Delta p/p/sup 2/=0.0008 (GeV/c)/sup -1/, close to the design specifications, is reached. >