Search results for "Instrumentation"
showing 10 items of 4914 documents
Feasibility of Ultra-Short-Term Analysis of Heart Rate and Systolic Arterial Pressure Variability at Rest and during Stress via Time-Domain and Entro…
2022
Heart Rate Variability (HRV) and Blood Pressure Variability (BPV) are widely employed tools for characterizing the complex behavior of cardiovascular dynamics. Usually, HRV and BPV analyses are carried out through short-term (ST) measurements, which exploit ~five-minute-long recordings. Recent research efforts are focused on reducing the time series length, assessing whether and to what extent Ultra-Short-Term (UST) analysis is capable of extracting information about cardiovascular variability from very short recordings. In this work, we compare ST and UST measures computed on electrocardiographic R-R intervals and systolic arterial pressure time series obtained at rest and during both post…
Acoustic, myoelectric, and aerodynamic parameters of euphonic and dysphonic voices: a systematic review of clinical studies
2021
Background: At present, there is no clinical consensus on the concept of normal and dysphonic voices. For many years, the establishment of a consensus on the terminology related to normal and pathological voices has been studied, in order to facilitate the communication between professionals in the field of the voice. Aim: systematically review the literature to compare and learn more precisely the measurable and objective characteristics of the acoustic, aerodynamic and surface electromyographic parameters of the normal and dysphonic voices. Methods: The PRISMA 2020 methodology was used as a review protocol together with the PICO procedure to answer the research question through six databa…
Correlative Raman-Electron-Light (CREL) Microscopy Analysis of Lipid Droplets in Melanoma Cancer Stem Cells.
2022
Among all neoplasms, melanoma is characterized by a very high percentage of cancer stem cells (CSCs). Several markers have been proposed for their identification, and lipid droplets (LDs) are among them. Different techniques are used for their characterization such as mass spectrometry, imaging techniques, and vibrational spectroscopies. Some emerging experimental approaches for the study of LDs are represented by correlative light–electron microscopy and by correlative Raman imaging–scanning electron microscopy (SEM). Based on these scientific approaches, we developed a novel methodology (CREL) by combining Raman micro-spectroscopy, confocal fluorescence microscopy, and SEM coupled with an…
Improved calculations of beta decay backgrounds to new physics in liquid xenon detectors
2020
We present high-precision theoretical predictions for the electron energy spectra for the ground-state to ground-state $\beta$ decays of $^{214}$Pb, $^{212}$Pb, and $^{85}$Kr most relevant to the background of liquid xenon dark matter detectors. The effects of nuclear structure on the spectral shapes are taken into account using large-scale shell model calculations. Final spectra also include atomic screening and exchange effects. The impact of nuclear structure effects on the $^{214}$Pb and $^{212}$Pb spectra below $\approx100$ keV, pertinent for several searches for new physics, are found to be comparatively larger than those from the atomic effects alone. We find that the full calculatio…
Measurement of the SMC muon beam polarisation using the asymmetry in the elastic scattering off polarised electrons
2000
A muon beam polarimeter was built for the SMC experiment at the CERN SPS, for beam energies of 100 and 190 GeV. The beam polarisation is determined from the asymmetry in the elastic scattering off the polarised electrons of a ferromagnetic target whose magnetisation is periodically reversed. At muon energies of 100 and 190 GeV the measured polarisation is P-mu = -0.80 +/- 0.03 (stat.) +/- 0.02 (syst.) and P-mu = - 0.797 +/- 0.011 (stat.) +/- 0.012 (syst.), respectively. These results agree with measurements of the beam polarisation using a shape analysis of the decay positron energy spectrum. (C) 2000 Elsevier Science B.V. All rights reserved.
Electron and photon performance measurements with the ATLAS detector using the 2015-2017 LHC proton-proton collision data
2019
This paper describes the reconstruction of electrons and photons with the ATLAS detector, employed for measurements and searches exploiting the complete LHC Run 2 dataset. An improved energy clustering algorithm is introduced, and its implications for the measurement and identification of prompt electrons and photons are discussed in detail. Corrections and calibrations that affect performance, including energy calibration, identification and isolation efficiencies, and the measurement of the charge of reconstructed electron candidates are determined using up to 81 fb−1 of proton-proton collision data collected at √s=13 TeV between 2015 and 2017.
The TRAPSENSOR facility: an open-ring 7 tesla Penning trap for laserbased precision experiments
2019
APenning-trap facility for high-precision mass spectrometry based on a novel detection method has been built. This method consists in measuring motional frequencies of singly-charged ions trapped in strong magnetic fields through the fluorescence photons from laser-cooled 40Ca+ ions, to overcome limitations faced in electronic single-ion detection techniques. The key element of this facility is an open-ring Penning trap coupled upstream to a preparation Penning trap similar to those used at Radioactive Ion Beam facilities. Here we present a full characterization of the trap and demonstrate motional frequency measurements of trapped ions stored by applying external radiofrequency fields in r…
Development of a New Clusterization Method for the GEM-TPC Detector
2022
The Facility for Antiproton and Ion Research FAIR, in Darmstadt Germany, will be one of the largest accelerator laboratories worldwide. The Superconducting FRagment Separator (Super-FRS)* is one of its main components. The Super-FRS can produce, separate and deliver high-energy radioactive beams with intensities up to 1e11 ions/s, covering projectiles from protons up to uranium and it can be used as an independent experimental device. The Gas Electron Multiplier-based Time Projection Chambers (GEM-TPC) in twin configuration is a newly developed beam tracking detector capable of providing spatial resolution of less than 1 mm with a tracking efficiency close to 100% at 1 MHz counting rate. Th…
Instrumental Odour Monitoring System Classification Performance Optimization by Analysis of Different Pattern-Recognition and Feature Extraction Tech…
2020
Instrumental odour monitoring systems (IOMS) are intelligent electronic sensing tools for which the primary application is the generation of odour metrics that are indicators of odour as perceived by human observers. The quality of the odour sensor signal, the mathematical treatment of the acquired data, and the validation of the correlation of the odour metric are key topics to control in order to ensure a robust and reliable measurement. The research presents and discusses the use of different pattern recognition and feature extraction techniques in the elaboration and effectiveness of the odour classification monitoring model (OCMM). The effect of the rise, intermediate, and peak period …
Trigeminal innervation of the mammalian pineal gland.
1999
There is evidence that the trigeminal (Gasserian) ganglia innervate the mamma- lian pineal gland and serve in its regulation in addition to the sympathetic and cholinergic as well as further influences. By means of immunohistochemical methods, previous studies demonstrated fibers containing calcitonin gene-related peptide (CGRP-LI) or substance P (SP) in the superficial pineal of various mammalian species. In addition, SP and the related tachykinin, neurokinin A, were detected by radioimmunoassay and HPLC, respectively, in the rat and human pineal gland. In the present study, retrograde neuronal tracing upon injection of a tracer substance into the superfical pineal gland of rats was used i…