Search results for "Instruments"
showing 10 items of 237 documents
Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards
2011
This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.
Virtual Instruments: Uncertainty Evaluation in the Presence of Electromagnetic Interferences
2007
The electromagnetic interferences can influence the performances of a virtual instrument; consequently, in a generic measurement performed by using these instruments, the related uncertainty values can increase. In the paper, we report the results of various experimental tests performed with the aim to check if and how the radiated and/or conducted disturbances affect the instruments' characteristics and, in particular, the single uncertainty sources. Starting from these results and applying an already proposed method for the uncertainty estimation in the measurements performed by means of virtual instruments, it is possible to take into account and to evaluate the contribute of the electro…
Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment
2013
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterraneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the beta beta 0 nu events provides a powerful background rejection factor for the bet…
Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture
2014
[EN] A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ∼35 cm drift × 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (∼23 l) so as to contain long (∼20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging fu…
Phase-shifting by means of an electronically tunable lens: quantitative phase imaging of biological specimens with digital holographic microscopy
2016
The use of an electronically tunable lens (ETL) to produce controlled phase shifts in interferometric arrangements is shown. The performance of the ETL as a phase-shifting device is experimentally validated in phase-shifting digital holographic microscopy. Quantitative phase maps of a section of the thorax of a Drosophila melanogaster fly and of human red blood cells have been obtained using our proposal. The experimental results validate the possibility of using the ETL as a reliable phase-shifter device.
Accurate single-shot quantitative phase imaging of biological specimens with telecentric digital holographic microscopy
2014
The advantages of using a telecentric imaging system in digital holographic microscopy (DHM) to study biological specimens are highlighted. To this end, the performances of nontelecentric DHM and telecentric DHM are evaluated from the quantitative phase imaging (QPI) point of view. The evaluated stability of the microscope allows single-shot QPI in DHM by using telecentric imaging systems. Quantitative phase maps of a section of the head of the drosophila melanogaster fly and of red blood cells are obtained via single-shot DHM with no numerical postprocessing. With these maps we show that the use of telecentric DHM provides larger field of view for a given magnification and permits more acc…
Probing the physics of the solar atmosphere with the Multi-slit Solar Explorer (MUSE): I. Coronal Heating
2022
The Multi-slit Solar Explorer (MUSE) is a proposed NASA MIDEX mission, currently in Phase A, composed of a multi-slit EUV spectrograph (in three narrow spectral bands centered around 171A, 284A, and 108A) and an EUV context imager (in two narrow passbands around 195A and 304A). MUSE will provide unprecedented spectral and imaging diagnostics of the solar corona at high spatial (<0.5 arcsec), and temporal resolution (down to ~0.5s) thanks to its innovative multi-slit design. By obtaining spectra in 4 bright EUV lines (Fe IX 171A , Fe XV 284A, Fe XIX-Fe XXI 108A) covering a wide range of transition region and coronal temperatures along 37 slits simultaneously, MUSE will for the first time …
An Examination of the Structure of the Career Decision Self-Efficacy Scale (Short Form) Among Italian High School Students
2013
This study aims to evaluate the factor structure of Career Decision Self-Efficacy scale-short form in a sample of Italian high school adolescents. confirmatory factor analysis (CFA) was used to test the degree to which a one-factor structure and a five-factor structure provided the best fit. In view of available research the five-factor structure was expected to provide the best fit. Moreover, factorial invariance in males and females was tested. It was expected to be invariant across groups. As expected the five-factor structure showed a better fit than the one-factor model and the factorial invariance resulted invariant across boys and girls.
The Lightfield Microscope Eyepiece
2021
Lightfield microscopy has raised growing interest in the last few years. Its ability to get three-dimensional information about the sample in a single shot makes it suitable for many applications in which time resolution is fundamental. In this paper we present a novel device, which is capable of converting any conventional microscope into a lightfield microscope. Based on the Fourier integral microscope concept, we designed the lightfield microscope eyepiece. This is coupled to the eyepiece port, to let the user exploit all the host microscope’s components (objective turret, illumination systems, translation stage, etc.) and get a 3D reconstruction of the sample. After the optical design, …
Absorption of European Funds by Romania
2014
Abstract The European Union provides financial support to all Member States through structural instruments (Structural Funds) and the Fund for Agriculture. Nationally, each Member State has to set up operational programs (SOP) in accordance with European requirements to access the available money. In the current multiannual financial exercise there are 7 SOP, plus the agriculture program. The absorption level of European funds for the current financial period - 2007-2013 - is low for several reasons: lack of strategic vision for programming development, poor quality of projects, excessive bureaucracy, lack of optimization of financial flows etc. For the upcoming 2014-2020 financial programm…