Search results for "Intraocular"

showing 10 items of 447 documents

Effect of large positioning holes on capsule fixation of plate-haptic intraocular lenses

2000

Abstract Purpose To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. Setting Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. Methods In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted under standardized conditions by the same surgeon. The IOL position was documented at the end of surgery and by retroillumination on the first day and 5 months postoperatively. The positioning-hole area was evaluated by ultrasound biomicroscopy (50 MHz) 5 months postoperatively. Results One day postoperatively, no IOL in either group was decentered more than 1.0 mm. Aft…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseLens Capsule CrystallineUltrasound biomicroscopyIntraocular lensProsthesis Designlaw.inventionFixation (surgical)Foreign-Body MigrationLens Implantation IntraocularlawOphthalmologyHumansMedicineProspective StudiesCapsulorhexisAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industrySuture TechniquesCapsuleMiddle Agedmedicine.diseaseCapsulorhexiseye diseasesSensory SystemsSurgeryLens (optics)OphthalmologyCapsulotomyFemaleSurgerysense organsbusinessCell DivisionJournal of Cataract and Refractive Surgery
researchProduct

Clinical magnification and residual refraction after implantation of a double intraocular lens system in patients with macular degeneration

2007

Purpose To evaluate the efficacy of a standard double intraocular lens (IOL) system (IOL-Vip) in patients with low vision and central scotoma due to macular degeneration and assess the predictability of the residual refraction and magnification. Setting Ophthalmology Department, Hospital General Universitario, Valencia, Spain. Methods This interventional prospective noncomparative case series comprised 13 consecutive surgical procedures in 10 patients with central scotoma. Follow-up was 12 months. Evaluation included the difference between preoperative and postoperative best corrected visual acuity (BCVA), refraction, position of the IOLs, endothelial cell density, and occurrence of postope…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseVisual AcuityVision LowMagnificationIntraocular lensRefraction OcularMacular DegenerationLens Implantation IntraocularOphthalmologyHumansMedicineProspective StudiesScotomaCentral scotomaAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryMiddle AgedMacular degenerationmedicine.diseaseRefractioneye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeMaculopathyFemaleSurgerysense organsbusinessRetinopathyJournal of Cataract and Refractive Surgery
researchProduct

Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.

2011

Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisCataract ExtractionRefraction OcularBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses Intraocularmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyGeneral MedicineMultifocal intraocular lensMiddle AgedCorneal topographySubjective refractionRefractioneye diseasesOphthalmologyHyperopiaFemalesense organsbusinessEuropean journal of ophthalmology
researchProduct

One-Year Outcomes with New-Generation Multifocal Intraocular Lenses

2007

Purpose: To compare new-generation multifocal intraocular lenses (IOLs) with monofocal IOLs. Design: Randomized prospective clinical trial. Participants: Sixty-two consecutive patients with cataract, seen between January of 2005 and January of 2006 at the Department of Ophthalmology of Palermo University Hospital in Italy, were bilaterally implanted with monofocal (AR 40, Advanced Medical Optics [AMO], Santa Ana, CA; 15 patients), multifocal refractive (Array SA40N, AMO; 16 patients), multifocal refractive (ReZoom, AMO; 15 patients), or multifocal diffractive pupil-independent (Tecnis ZM900, AMO; 16 patients) IOLs. Intervention: Bimanual phacoemulsification. Main Outcome Measures: Primary o…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignGlareContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologylente refrattiva chirurgia della catarattaHumansMedicineContrast (vision)Prospective StudiesDioptreAgedmedia_commonLenses IntraocularDepth PerceptionPhacoemulsificationSettore MED/30 - Malattie Apparato Visivobusiness.industryLe lenti multifocali intraoculari di nuova generazioneGlare (vision)PhacoemulsificationMiddle AgedMultifocal intraocular lensUniversity hospitaleye diseasesOphthalmologyTreatment Outcomelente diffrattivaPatient SatisfactionQuality of LifeOptometryMultifocal IOLsFemalesense organsbusinessOphthalmology
researchProduct

Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation

2003

Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…

Malemedicine.medical_specialtymedicine.medical_treatmentAcrylic ResinsLens Capsule CrystallineIntraocular lensPositive correlationCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageLenses IntraocularPhacoemulsificationbusiness.industryCapsulePhacoemulsificationCataract surgeryCapsulorhexisSensory SystemsOphthalmologyCapsular bagFemaleSurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

2005

To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…

Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessJournal of cataract and refractive surgery
researchProduct

Central retinal artery occlusion-A new, provisional treatment approach.

2019

The retinal ganglion cells infarcted in central retinal artery occlusion (CRAO) are the somata of the optic nerve axons, part of the central nervous system. Consequently, CRAO with inner retinal infarction is a small vessel stroke, usually with the devastating consequence of severe visual loss in the affected eye. At present, there is no generally accepted, evidence-based therapy of nonarteritic CRAO in contrast to ischemic cerebral stroke that has well-accepted treatment protocols. Widely divergent and controversial therapeutic options for CRAO reflect the desperation of treating physicians and disparate conflicting studies. We examine reasons why treatment of nonarteritic CRAO remains pro…

MassageRetinal Ganglion Cellsmedicine.medical_specialtybusiness.industryRetinal Artery OcclusionAnticoagulantsCherry-red spotCerebral strokemedicine.diseaseRetinal ganglionOphthalmologyFibrinolytic AgentsOphthalmologyOptic nerveMedicineCentral retinal artery occlusionHumansSmall vesselmedicine.symptombusinessStrokeAntihypertensive AgentsIntraocular PressureRetinal infarctionSurvey of ophthalmology
researchProduct

A New Method for Direct Detection of Heparin on Surface-Modified Intraocular Lenses

1997

Background: Examination of surface-bound heparin on synthetic polymers can only be performed by few staining methods. These methods are limited by an only approximate detection of heparin visible at high magnification. Other methods only measure heparin quantitatively (per square dimension) and are rather sensitive to artifacts. Due to its homogeneous staining pattern, the modified toluidine blue staining technique, using a non-protein-based substance, allows examination and analysis of the homogeneity of the monomolecular heparin layer even under critical conditions like scanning electron microscopy. Materials and Methods: For critical examination of the heparin layer, this method was used…

Materials sciencegenetic structuresToluidine Blue Staining Methodbusiness.industryScanning electron microscopemedicine.medical_treatmentTolonium chlorideIntraocular lensGeneral MedicineHeparinSensory SystemsStainingOphthalmologychemistry.chemical_compoundOpticschemistryMicroscopymedicineToluidinebusinessBiomedical engineeringmedicine.drugOphthalmologica
researchProduct

Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.

2011

Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…

Materials sciencegenetic structuresUltraviolet Raysmedicine.medical_treatmentIntraocular lensRadiationmedicine.disease_causelaw.inventionOpticsRadiation ProtectionlawLens CrystallinemedicineAnimalsHumansIrradiationLenses Intraocularbusiness.industryMediterranean RegionAlbedoeye diseasesLens (optics)OphthalmologyWavelengthmedicine.anatomical_structureSunlightHuman eyesense organsRabbitsbusinessUltravioletJournal francais d'ophtalmologie
researchProduct

Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…

2021

Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…

Medicine (General)medicine.medical_specialtyIntraocular Lens Dislocationgenetic structuresmedicine.medical_treatmentIntraocular lensAfter cataractArticleCataractlate intraocular lens dislocationR5-920Postoperative ComplicationsLens Implantation IntraocularmedicineHumansProspective StudiesProspective cohort studyweak zonules; anterior capsule opening reduction; late intraocular lens dislocation; capsular tension ringReduction (orthopedic surgery)Lenses IntraocularPhacoemulsificationbusiness.industryweak zonulescapsular tension ringGeneral MedicinePhacoemulsificationCataract surgeryLens Subluxationmedicine.diseaseComorbidityeye diseasesSurgeryanterior capsule opening reductionsense organsbusinessMedicina
researchProduct