Search results for "Ionization"
showing 10 items of 1255 documents
Determination of triazines and organophosphorus pesticides in water samples using solid-phase extraction.
1991
Abstract Octadecyl (C 18 )-bonded porous silica was evaluated for the extraction of triazine and organophosphorus pesticides from natural water. The extraction results showed an effective performance when 1 l of water was passed through small glass columns containing 500 mg of 50–100-μm C 18 bonded porous silica. The absorbed compounds were removed with ethyl acetate, evaporated to 200 μl and determined by gas chromatography. The overall average recoveries were greater than 85% except for dimethoate and trichlorfon. Application of this procedure to the analysis of natural water samples gave results that agree well with those obtained by solvent extraction methods.
An electrospray ionization mass spectrometric study of the extracellular hemoglobins from Chironomus thummi thummi.
1998
The aquatic larvae of the dipteran, Chironomus thummi thummi contain extracellular hemoglobins which exhibit stage-specific expression. We have used maximum entropy-based deconvolution of the complex, multiply charged electrospray ionization mass spectra, to demonstrate the presence of more than 20 components, ranging in mass from 14,417.3 Da to 17,356.5 Da in the 4th instar larvae. Of the 15 major peaks with intensities > 10 relative to 100 for the 14,417.3 Da-component (CTT-IV), only the 15,528.2-Da peak does not correspond to a known amino acid sequence. Since the number of C. thummi thummi globin genes now stands at 27, including one cDNA and not counting three that must encode known gl…
Method development for the determination of 1,1-dimethylhydrazine by the high-performance liquid chromatography-mass spectrometry technique.
2018
Unsymmetrical dimethyl hydrazine is highly toxic, carcinogenic compound, widely used for organic synthesis and drug development. Therefore, due to its high reactivity, direct analysis is problematic. Current study proposes to use derivatization reaction to increase selectivity and sensitivity of high-performance liquid chromatography–mass spectrometry method. Different derivatization agents were tested and optimal reaction media was found. Derivatization was performed by using small amounts of reagents to lower the cost of analysis. The full validation of the method was performed and it can be used in a routine control in pharmaceutical analysis. Method sensitivity is 0.15 ppm, and lineari…
Chromium(VI) oxide oxidation of non-ethoxylated and ethoxylated alcohols for determination by electrospray ionization mass spectrometry
2010
A new derivatization procedure to increase the sensitivity of electrospray ionization mass spectrometry (ESI-MS) to non-ethoxylated and ethoxylated alcohols was investigated. The analytes were oxidized with chromium(VI) oxide and the resulting carboxylic and ethoxy-carboxylic acids were isolated by extraction with ethyl acetate; the extracts were alkalinized and infused into the ESI-MS system working in the negative-ion mode. The yields of the combined oxidation-extraction were ca. 100% for non-ethoxylated fatty alcohols dissolved in acetone and they decreased moderately in samples containing increasing amounts of water (e.g., a 75% yield was obtained with 50% water). Ethoxylated alcohols w…
Analysis of neuropeptide Y and its metabolites by high-performance liquid chromatography-electrospray ionization mass spectrometry and integrated sam…
2000
A novel restricted access cation exchanger with sulphonic acid groups at the internal surface was proven to be highly suitable in the sample clean up of peptides on-line coupled to HPLC-electrospray ionization (ESI)-MS. Neuropeptide Y (NPY) and several of its fragments in plasma were subjected to the sample clean-up procedure. The peptides were eluted by a step gradient from the restricted access column, applying 10 mM phosphate buffer pH 3.5 from 5 to 20% (v/v) of acetonitrile with 1 M NaCl and transferred to a Micra ODS II column (33x4.6 mm). The separation of the peptides and their fragments was performed by a linear gradient from 20 to 60% (v/v) acetonitrile in water with 0.1% formic ac…
An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.
2002
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…
Determination of several aminoglycoside and macrolide antibiotics in animal tissues by liquid chromatography-electrospray ionization-tandem mass spec…
2008
Simultaneous determination of imidacloprid, carbendazim, methiocarb and hexythiazox in peaches and nectarines by liquid chromatography–mass spectrome…
2002
Abstract A liquid chromatographic (LC) atmospheric pressure chemical ionization mass spectrometric (MS) method is described for determining imidacloprid, carbendazim, methiocarb and hexythiazox in peaches and nectarines. The samples were extracted with ethyl acetate and anhydrous sodium sulfate. Recoveries yield for spiking samples were ranged from 64±9% (R.S.D) for carbendazim to 108±14% (R.S.D.) for hexythiazox at the concentration of 0.1 mg kg−1 (n=5). The correlation coefficients were greater than 0.998 over the range between 0.02 and 2 mg kg−1. The limits of quantitation (LOQ) were 0.02 mg kg−1 for all the pesticides. The applicability of the method to detect and quantify imidacloprid,…
Gas chromatographic separation of acetylated chlorinated phenols, guaiacols and catechols on an SE-30 quartz capillary column
1983
The Role of the Liquid Chromatography-Mass Spectrometry in Pesticide Residue Determination in Food
2008
The use of liquid chromatography (LC) in pesticide residue determination was usually limited to groups of compounds or single compounds for which no suitable gas chromatographic (GC) conditions were available. However, recent developments have significantly enlarged the LC scope in this field of analysis. One of the most important advances was the on-line coupling of efficient LC separation with mass spectrometry detectors (LC-MS and LC-MS/MS) that makes this technique an excellent method for the determination of pesticides and their transformation products in complex matrices such as food. This review considers the application of LC-MS/MS in this field. Emphasis is placed on the tandem MS …