Search results for "Iridium"

showing 10 items of 296 documents

Monte Carlo calculation of dose rate distributions around 192Ir wires.

1997

Monte Carlo calculations of absolute dose rate in liquid water are presented in the form of away-along tables for 1 and 5 cm 192 Ir wires of 0.3 mm diameter. Simulated absolute dose rate values can be used as benchmark data to verify the calculation results of treatment planning systems or directly as input data for treatment planning. Best fit value of attenuation coefficient suitable for use in Sievert-integrals-type calculations has been derived based on Monte Carlo calculation results. For the treatment planning systems that are based on TG43 formalism we have also calculated the required dosimetry parameters.

PhysicsLiquid waterRadiotherapy Planning Computer-AssistedMonte Carlo methodBrachytherapyBiophysicsRadiotherapy DosageGeneral MedicineReference StandardsIridium RadioisotopesBiophysical PhenomenaComputational physicsEvaluation Studies as TopicAttenuation coefficientNeoplasmsDynamic Monte Carlo methodDosimetryHumansComputer SimulationStatistical physicsBenchmark dataDose rateMonte Carlo MethodMedical physics
researchProduct

Monte Carlo dosimetry of the Buchler high dose rate 192Ir source.

2001

In this study a complete set of dosimetric data is presented for the high dose rate (HDR) source from Amersham used in the Buchler remote afterloading HDR unit. These data have been calculated by means of the Monte Carlo simulation code GEANT taking into account the detailed geometry of the source. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian look-up tables. All dosimetric quantities recommended by the AAPM Task Group 43 report have been calculated. Quantities determined are: dose rate constant, radial dose function, anisotropy function, anisotropy factor and anisotropy constant. The dose rate distributions of th…

PhysicsRadiological and Ultrasound Technologymedicine.medical_treatmentPhysics::Medical PhysicsMonte Carlo methodBrachytherapyBrachytherapyRadiotherapy DosageFunction (mathematics)Equipment DesignIridium Radioisotopeslaw.inventionComputational physicslawmedicineDosimetryAnisotropyRadiology Nuclear Medicine and imagingCartesian coordinate systemAnisotropyConstant (mathematics)Dose rateMonte Carlo MethodSimulationPhysics in medicine and biology
researchProduct

The Cryogenic AntiCoincidence Detector Project for ATHENA+: An Overview Up to the Present Status

2014

ATHENA+ is a space mission proposal for the next ESA L2-L3 slot. One of the focal plane instruments is the X-ray integral field unit (X-IFU) working in the energy range 0.3–10 keV. It is a multi-array based on TES detectors aimed at characterizing faint or diffuse sources (e.g. WHIM or galaxy outskirt). The X-IFU will be able to achieve the required sensitivity if a low background is guaranteed. The studies performed by GEANT4 simulations depict a scenario where the use of an active anticoincidence (AC) is mandatory to reduce the background expected in L2 orbit down to the goal level of 0.005 cts cm $$^{-2}$$  s $$^{-1}$$  keV $$^{-1}$$ . This is possible using a cryogenic anticoincidence (…

PhysicsSiliconbusiness.industryAnticoincidence detectorDetectorOrder (ring theory)SpaceTES Silicon Iridium Anticoincidence detector SpaceIridiumCondensed Matter PhysicsAtomic and Molecular Physics and OpticsGalaxyOpticsCardinal pointAnticoincidence detector; Iridium; Silicon; Space; TES; Atomic and Molecular Physics and Optics; Materials Science (all); Condensed Matter PhysicsSettore FIS/05 - Astronomia E AstrofisicaAtomic and Molecular PhysicsOrbit (dynamics)General Materials ScienceSensitivity (control systems)Materials Science (all)and OpticsbusinessTESEnergy (signal processing)
researchProduct

Dosimetry characteristics of the Plus and 12i Gammamed PDR 192Ir sources.

2001

In this study a complete set of dosimetric data for the Plus and 12i Gammamed PDR (pulsed dose rate) 192 Ir sources is presented. These data have been calculated using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water around these sources were calculated and are presented in form of conventional two dimensional (2D) Cartesian look-up tables. All dosimetric quantities recommended by the AAPM Task Group 43 report have been also calculated. These quantities are dose rate constant, radial dose function, anisotropy function and anisotropy factor. The dose rate distribution of the 12i source was compared with the corresponding data for the microselectron PDR source…

PhysicsTask groupbusiness.industrymedicine.medical_treatmentAirPhysics::Medical PhysicsBrachytherapyMonte Carlo methodPulsed dose rateWaterGeneral MedicineFunction (mathematics)Iridium RadioisotopesComputational physicsmedicineDosimetryAnisotropyParticle AcceleratorsDose rateAnisotropyNuclear medicinebusinessRadiometryMonte Carlo MethodMedical physics
researchProduct

Gamma bands in doubly odd rhenium and iridium nuclei

2015

Structure of the |K ± 2| bands in doubly-odd nuclei belonging to the transitional deformation region at A∼190 is discussed. Relation of these quasi gamma-bands with the non-axial deformation of the parent two- quasiparticle configurations is studied. Using available experimental information, new tentative |K ± 2| bands are proposed in 188 Re, and 192,194 Ir nuclei. Coexistence of two-quasiparticle states with different deformation modes is considered in the case of 188 Re and 194 Ir.

PhysicschemistryPhysicsQC1-999Quasiparticlechemistry.chemical_elementIridiumDeformation (meteorology)Atomic physicsRheniumEPJ Web of Conferences
researchProduct

Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.

2001

In this study a complete set of dosimetric data for the GammaMed high dose rate (HDR) 12i and Plus 192 Ir sources are presented. These data have been calculated by means of the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water are presented as conventional two dimensional (2D) Cartesian look-up tables, and in the TG43 formalism.

Physicsmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyBiophysicsWaterTechnical noteGeneral MedicineIridium RadioisotopesBiophysical PhenomenaComputational physicslaw.inventionFormalism (philosophy of mathematics)lawmedicineEconometricsDosimetryAnisotropyCartesian coordinate systemDose rateRadiometryMonte Carlo MethodMedical physics
researchProduct

On the Use of Metal Purine Derivatives (M=Ir, Rh) for the Selective Labeling of Nucleosides and Nucleotides

2014

The reactions of neutral or cationic IrIII and RhIII derivatives of phenyl purine nucleobases with unsymmetrical alkynes produce new metallacycles in a predictable manner, which allows for the incorporation of either photoactive (anthracene or pyrene) or electroactive (ferrocene) labels in the nucleotide or nucleoside moiety. The reported methodology (metalation of the purine derivative and subsequent marker insertion) could be used for the postfunctionalization and unambiguous labeling of oligonucleotides.

PurineMetalationIridiumCatalysisNucleobasechemistry.chemical_compoundOrganometallic CompoundsOrganic chemistryMoietyRhodiumNucleotideNuclear Magnetic Resonance BiomolecularPurine NucleotidesAnthraceneschemistry.chemical_classificationPyrenesMolecular StructureOrganic ChemistryCationic polymerizationPurine NucleosidesGeneral ChemistryCombinatorial chemistryFerrocenechemistryAlkynesNucleosideChemistry - A European Journal
researchProduct

Improved stability of solid state light emitting electrochemical cells consisting of ruthenium and iridium complexes

2006

ABSTRACTTwo charged organometallic complexes containing bulky hydrophobic ligands based on ruthenium (II) and iridium (III) were synthesized and their performance in solid state light emitting electrochemical cells is described. The complexes were chosen as due to their large ligands a diminished susceptibility towards the formation of destructive complexes during device operation is expected. The LEC device performances reveal the longest living devices reported so far under dc bias. Quantum chemical calculations confirm that the major effect of the bulky diphenylphenanthroline ligands is of steric origin and not related with changes in the molecular electronic structure of the complexes.

Quantum chemicalSteric effectsMaterials sciencechemistryMolecular electronic structureSolid-statechemistry.chemical_elementIridiumPhotochemistryElectrochemical cellRuthenium
researchProduct

Ab initiophase diagram of iridium

2016

The phase diagram of iridium is investigated using the Z methodology. The Z methodology is a technique for phase diagram studies that combines the direct Z method for the computation of melting curves and the inverse Z method for the calculation of solid-solid phase boundaries. In the direct Z method, the solid phases along the melting curve are determined by comparing the solid-liquid equilibrium boundaries of candidate crystal structures. The inverse Z method involves quenching the liquid into the most stable solid phase at various temperatures and pressures to locate a solid-solid boundary. Although excellent agreement with the available experimental data (to less than or similar to 65 G…

QuenchingMaterials scienceEquation of state (cosmology)Ab initioInverseThermodynamicschemistry.chemical_element02 engineering and technologyCrystal structureCondensed Matter Physics021001 nanoscience & nanotechnology01 natural scienceschemistryPhase (matter)0103 physical sciencesPhysical chemistryIridium010306 general physics0210 nano-technologyDen kondenserade materiens fysikPhase diagramPhysical Review B
researchProduct

Increasing the efficiency of light-emitting electrochemical cells by limiting the exciton quenching

2013

ABSTRACTLight-emitting electrochemical cells (LECs) are one of the simplest electroluminescent devices. The possibility to be processed from solution and to operate with air-stable materials makes them an attractive alternative to organic light emitting diodes (OLEDs). Still their efficiencies are below those obtained in OLEDs. Additionally the best efficiencies were reported at low luminances and sustained for a short period of time. Here we show that for a LEC employing an orange-emitting charged iridium complex that is driven using a pulsed driving scheme high efficiencies of up to 20.5 cd A-1 can be obtained at high luminance and sustained over the device lifetime. It is also shown that…

QuenchingMaterials sciencebusiness.industryExcitonchemistry.chemical_elementElectroluminescenceElectrochemical cellchemistryOLEDOptoelectronicsIridiumbusinessLuminescenceCurrent densityMRS Proceedings
researchProduct