Search results for "Isobar"

showing 10 items of 210 documents

Proposal of Isobutyl Alcohol as Entrainer To Separate Mixtures Formed by Ethanol and Water and 1-Propanol and Water

2017

Isobutyl alcohol (IBA) has been proposed as a solvent to carry out the dehydration of ethanol and 1-propanol by means of a nonconventional distillation process. In this way, isobaric vapor–liquid equilibrium (VLE) and vapor–liquid–liquid equilibrium (VLLE) data at atmospheric pressure have been obtained for the ternary systems ethanol (1a) + water (2) + IBA (3) and 1-propanol (1b) + water (2) + IBA (3). Then, these data have been correlated to obtain a set of parameters capable of estimating VLE and VLLE. According to the results achieved, distillation sequences to separate water and ethanol or 1-propanol have been proposed. Finally, a study about the minimum amount of entrainer required to…

EthanolChromatographyGeneral Chemical EngineeringAnalytical chemistry02 engineering and technologyGeneral Chemistry021001 nanoscience & nanotechnologymedicine.diseaselaw.inventionSolventchemistry.chemical_compound1-Propanol020401 chemical engineeringchemistrylawAzeotropemedicineIsobaric processDehydration0204 chemical engineering0210 nano-technologyTernary operationDistillationJournal of Chemical & Engineering Data
researchProduct

Thermodynamic Analysis and Process Simulation of Ethanol Dehydration via Heterogeneous Azeotropic Distillation

2014

The heterogeneous azeotropic distillation process is widely used to separate nonideal binary mixtures into their constituent pure components. This method uses the addition of a third component, called an entrainer, to cause liquid–liquid phase separation over a broad range of compositions in the ternary phase diagram. Ethanol dehydration was used as a case study and diisopropyl ether and isobutyl alcohol were analyzed as possible entrainers in a heterogeneous azeotropic distillation. In this way, isobaric vapor–liquid–liquid equilibrium was measured for the ethanol + water + diisopropyl ether or + isobutyl alcohol ternary mixtures at 101.3 kPa. The data were correlated by the NRTL and UNIQU…

EthanolUNIQUACGeneral Chemical EngineeringThermodynamicsGeneral Chemistrymedicine.diseaseIndustrial and Manufacturing Engineeringchemistry.chemical_compoundchemistryAzeotropic distillationNon-random two-liquid modelmedicineIsobaric processDiisopropyl etherDehydrationTernary operationIndustrial & Engineering Chemistry Research
researchProduct

T=5/2states in9Li:Isobaric analog states of9He

2003

The thick target inverse kinematic method was applied to the study of isobaric analog states in the neutron-rich nucleus ${}^{9}\mathrm{Li}.$ For this purpose, an excitation function for ${}^{8}\mathrm{He}+p$ elastic scattering was measured in the center-of-momentum energy range from 1.6 to 5.8 MeV. Three $T=5/2$ states in ${}^{9}\mathrm{Li}$ (isobaric analogs of ${}^{9}\mathrm{He})$ were observed. Restrictions on the spin-parity assignments are provided according to R-matrix calculations, and conclusions regarding the structure of ${}^{9}\mathrm{He}$ are given.

Excitation functionPhysicsElastic scatteringNuclear and High Energy PhysicsNuclear TheoryInverseIsobaric processAtomic physicsNuclear ExperimentEnergy (signal processing)Physical Review C
researchProduct

Molecular structures inT=1states of10B

2011

Multi-center (molecular) structures can play an important role in light nuclei. The highly deformed rotational band in 10Be with band head at 6.179 MeV has been observed recently and suggested to have an exotic alpha:2n:alpha configuration. A search for states with alpha:pn:alpha two-center molecular configurations in 10B that are analogous to the states with alpha:2n:alpha structure in 10Be has been performed. The T=1 isobaric analog states in 10B were studied in the excitation energy range of E=8.7-12.1 MeV using the reaction 1H(9Be,alpha)6Li*(T=1, 0+, 3.56 MeV). An R-matrix analysis was used to extract parameters for the states observed in the (p,alpha) excitation function. Five T=1 stat…

Excitation functionPhysicsNuclear and High Energy PhysicsRange (particle radiation)Light nucleus010308 nuclear & particles physicsAlpha (ethology)State (functional analysis)01 natural sciences0103 physical sciencesIsobaric processAtomic physics010306 general physicsExcitationPhysical Review C
researchProduct

Isobaric Vapor–Liquid Equilibria of 1-Propanol + Water + Trifluoromethanesulfonate-Based Ionic Liquid Ternary Systems at 100 kPa

2011

Isobaric vapor–liquid equilibria (VLE) for the 1-propanol + 1-butyl-3-ethylimidazolium trifluoromethanesulfonate ([beim][triflate]), water + [beim][triflate], 1-propanol + 1-butyl-1-methylpyrrolidinium trifluoromethanesulfonate ([bmpyr][triflate]), and water + [bmpyr][triflate] binary systems, as well as the VLE for the 1-propanol + water + [beim][triflate] and 1-propanol + water + [bmpyr][triflate] ternary systems have been obtained at 100 kPa using a recirculating still. The salting-out effect on the 1-propanol produced by the [bmpyr][triflate] was stronger than that produced by the [beim][triflate], although for the IL concentrations used in this study the effect was not enough to break …

General Chemical EngineeringInorganic chemistryGeneral ChemistryElectrolytechemistry.chemical_compound1-PropanolchemistryAzeotropeIonic liquidNon-random two-liquid modelPhysical chemistryIsobaric processTernary operationTrifluoromethanesulfonateJournal of Chemical & Engineering Data
researchProduct

A setup to develop novel Chemical Isobaric SEparation (CISE)

2020

Abstract Gas catchers are widely used to thermalize nuclear reaction products and subsequently extract them for precision measurements. However, impurities in the inert stopping gas can chemically react with the ions and thus influence the extraction efficiency. So far, chemical reactions in the gas-catcher have not been investigated in detail. Therefore, we are currently building a new setup to develop Chemical Isobaric SEparation (CISE) with the aim to understand the chemistry inside the gas-catcher and to explore its potential as a new technique for separation of isobars. In this paper, we give a short description of the setup together with the ion transportation studies performed via io…

InertNuclear and High Energy PhysicsGas catcherMass spectrometryNuclear engineeringExtraction (chemistry)Mass spectrometryChemical reactionIonGas-phase chemistryChemical isobaric separationImpuritySTOPPING CELLIsobarIsobaric processInstrumentationIon guideNuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms
researchProduct

Dispersive magnetic immunoaffinity extraction. Anatoxin-a determination.

2017

Specific monoclonal antibodies were coupled with magnetic Sepharose-based beads and used, for the first time. The methodology was applied to preconcentrate anatoxin-a from water and the later determination by ion mobility spectrometry (IMS). Dispersive magnetic immunoaffinity (d-MagIA) extraction methodology provided a limit of detection of 0.02μgL-1 and a satisfactory precision with a relative standard deviation lower than 15%. Recoveries were evaluated at 0.5, 1.0 and 5.0μgL-1 anatoxin-a with quantitative values from 91 to 115%. Additionally, isobaric interferences with phenylalanine were completely avoided by the use of the developed d-MagIA extraction coupled to IMS determinations.

Ion-mobility spectrometryRelative standard deviationAnalytical chemistry02 engineering and technology01 natural sciencesBiochemistryAnalytical ChemistryAnatoxin-aSepharosechemistry.chemical_compoundMagneticsLimit of DetectionIon Mobility SpectrometryDetection limitChromatographyCyanobacteria ToxinsSepharose010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Antibodies MonoclonalWaterGeneral Medicine021001 nanoscience & nanotechnology0104 chemical scienceschemistryIsobaric process0210 nano-technologyWater Pollutants ChemicalEnvironmental MonitoringTropanesJournal of chromatography. A
researchProduct

Anomalous and Not-So-Common Behavior in Common Ionic Liquids and Ionic Liquid-Containing Systems

2019

This work highlights unexpected, not so well known responses of ionic liquids and ionic liquid-containing systems, which are reported in a collective manner, as a short review. Examples include: (i) Minima in the temperature dependence of the isobaric thermal expansion coefficient of some ILs; (ii) Viscosity Minima in binary mixtures of IL + Molecular solvents; (iii) Anomalies in the surface tension within a family of ILs; (iv) The constancy among IL substitution of Cp/Vm at and around room temperature; (v) ILs as glass forming liquids; (vi) Alternate odd-even side alkyl chain length effects; (vii) Absolute negative pressures in ILs and IL-containing systems; (viii) Reversed-charged ionic l…

Ionic bondingThermodynamicsReview02 engineering and technology010402 general chemistry01 natural sciencesLower critical solution temperatureodd-even effectsThermal expansionionic liquidslcsh:ChemistrySurface tensionchemistry.chemical_compoundViscosityLCSTsurface tensionAlkylchemistry.chemical_classificationreversed charge ILsunusual behaviorGeneral Chemistry021001 nanoscience & nanotechnology0104 chemical sciencesChemistrylcsh:QD1-999chemistrythermal expansion coefficientviscosityIonic liquidIsobaric process0210 nano-technologyFrontiers in Chemistry
researchProduct

Ultratrace analysis of calcium with high isotopic selectivity by diodelaser resonance ionisation mass spectrometry

1997

A resonance ionisation mass spectrometer for the ultratrace determination of calcium isotopes is presented. It achieves high overall efficiency, ultra-high isotopic abundance sensitivity of more than 1010 and complete suppression of isobars. The system can be used for isotope ratio studies on stable and long-lived trace isotopes with the final goal of radiodating via 41Ca-determination. For the different applications optical one-, two- or three-step resonance excitation and subsequent ionisation is applied using simple and inexpensive diodelasers. Additional mass analysis is accomplished in a commercial quadrupole mass spectrometer. The experimental set-up and first results on synthetical a…

Isotopes of calciumIsotopeChemistryIonizationIsobarAnalytical chemistryResonanceNatural abundanceNuclear ExperimentMass spectrometryBiochemistryQuadrupole mass analyzerFresenius' Journal of Analytical Chemistry
researchProduct

Tensor Analyzing Powers for Quasi-Elastic Electron Scattering from Deuterium

1999

We report on a first measurement of tensor analyzing powers in quasi-elastic electron-deuteron scattering at an average three-momentum transfer of 1.7 fm$^{-1}$. Data sensitive to the spin-dependent nucleon density in the deuteron were obtained for missing momenta up to 150 MeV/$c$ with a tensor polarized $^2$H target internal to an electron storage ring. The data are well described by a calculation that includes the effects of final-state interaction, meson-exchange and isobar currents, and leading-order relativistic contributions.

MOMENTUM DISTRIBUTIONNuclear TheoryGeneral Physics and AstronomyFOS: Physical sciencesElectron01 natural scienceslaw.inventionNuclear physicslawNUCLEON CROSS-SECTIONS0103 physical sciencesTensorSTORAGE-RINGNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear ExperimentPhysicsFORM-FACTORPOLARIZED ELECTRONS010308 nuclear & particles physicsScatteringParticle accelerator3. Good healthTARGETDeuteriumIsobarNEUTRONNucleonElectron scattering
researchProduct