Search results for "Isotonic"

showing 10 items of 30 documents

Lung fixation for the preservation of air spaces.

2004

The procedures for the fixation of entire lungs of small rodents are presented together with various techniques used to verify the structural integrity of the lung tissue. To achieve this, the lungs were dissected out from rats and mice killed by ether overdose. The specimens were rinsed with isotonic saline and fixation solution under low vacuum conditions. After fixation, they were dried using alcohol and stored in a noncollapsed state (i.e., state of inhalation). Light and scanning electron microscopy as well as magnetic resonance imaging using hyperpolarized 3He were employed to verify the intact state on interalveolar septa and walls of smaller bronchi as well as accessibility of the a…

Pulmonary and Respiratory MedicineTissue FixationIsotonic salineClinical BiochemistryIn Vitro TechniquesSuctionHeliumRats Sprague-DawleyFixativesMiceLow vacuumFormaldehydemedicineAnimalsRespiratory systemMolecular BiologyFixation (histology)LungInhalationChemistryAirSyringesStructural integrityAnatomyrespiratory systemMagnetic Resonance ImagingRatsMice Inbred C57BLPulmonary Alveolimedicine.anatomical_structureAlcoholsMicroscopy Electron ScanningLung tissueExperimental lung research
researchProduct

The Effect of the Cranial Electrotherapy on the Muscle Motor Function in Different Operating Modes

2015

The aim of the present study was to analyze the effect of cranial electrotherapy stimulation on muscle function analysis indicators. Instrumental assessment of muscle function (on a REV9000, Technogym, Italy) was performed before and after cranial electrotherapy stimulation, assessments of the muscle function was performed during knee extension maximum voluntary, isometric contraction (MVIC), angle velocity with load 45Nm isotonic contraction and maximum pick torque in isokinetic contraction on 30°/s, 200°/s and 300°/s and neuromuscular efficiency measurements. To analyze data was used Excel program Statistics 3.1. Subjects of our study were twenty healthy athletes of sport fitness. 1 minu…

cranial electrical stimulation; dynamometer; electromyogram; isokinetic; isometric; isotonicIsokinetic contractionmedicine.medical_specialtyCranial electrotherapy stimulationCranial Electrical Stimulationbusiness.industrymedicine.medical_treatmentIsometric exerciseKnee extensionMotor functionPhysical medicine and rehabilitationElectrotherapyIsotonicPhysical therapyMedicinebusinessSOCIETY, INTEGRATION, EDUCATION. Proceedings of the International Scientific Conference
researchProduct

A comparison of elastic tubing and isotonic resistance exercises.

2010

The aim of this study was to assess eff ects of a short-term resistance program on strength in fi t young women using weight machines / free weights or elastic tubing. 42 physically fi t women (21.79 ± 0.7 years) were randomly assigned to the following groups: (i) the Thera-Band ® Exercise Station Group (TBG); (ii) the weight machines / free weights group (MFWG); or (iii) the control group (CG). Each experimental group performed the same periodised training program that lasted for 8 weeks, with 2 – 4 sessions per week and 3 – 4 sets of 8 – 15 submaximal reps. A load cell (Isocontrol; ATEmicro, Madrid, Spain) was used to test the evolution of the Maximum Isometric Voluntary Contraction (MIVC…

medicine.medical_specialtyAnalysis of VarianceStrength trainingRowingPhysical Therapy Sports Therapy and RehabilitationSquatPhysical exerciseResistance TrainingIsometric exerciseYoung AdultIsometric ContractionIsotonicPhysical therapymedicineHumansOrthopedics and Sports MedicineFemaleMuscle StrengthExercise physiologyTraining programMuscle SkeletalExerciseMathematicsInternational journal of sports medicine
researchProduct

Body mass reduction markedly improves muscle performance and body composition in obese females aged 61-75 years: comparison between the effects exert…

2004

OBJECTIVE: To investigate the effectiveness of a body mass reduction programme entailing diet caloric restriction and moderate physical activity with or without supplementary treatment with recombinant (r) GH or steroids to improve body composition and muscle performance in severely obese women aged 61-75 years. METHODS: Twenty women were randomly assigned to one of three groups: body mass reduction alone; body mass reduction plus rGH; body mass reduction plus nandrolone undecanoate. Body composition, isotonic muscle strength and anaerobic power output during jumping were determined before and after the 3-week period. RESULTS: Whatever the experimental group considered, body mass (P<0.01…

medicine.medical_specialtyDoseStrength trainingEndocrinology Diabetes and Metabolismmedicine.disease_causeBody Mass IndexEndocrinologyJumpingInternal medicinemedicineHumansNandroloneTestosteroneIsotonic ContractionObesityInsulin-Like Growth Factor IExerciseAgedNandrolone undecanoatebusiness.industryGeneral MedicineLuteinizing HormoneMiddle Agedmedicine.diseaseCombined Modality TherapyObesityEndocrinologyNandroloneGrowth HormoneBody CompositionFemaleFollicle Stimulating HormonebusinessBody mass indexAnaerobic exercisemedicine.drugEuropean Journal of Endocrinology
researchProduct

Characteristics of histamine tachyphylaxis in rat uterine smooth muscle.

2002

Objective and design: To study both the desensitisation induced by short-term exposure to histamine and the mechanism responsible in the isolated rat uterus.¶Material: Precontracted isolated uterus (37 mM KCl) from oestrogenised Wistar rats were used.¶Treatment: Repetitive responses to histamine (10–6, 10–5, 10–4, 10–3 M), dimaprit and clonidine (10–4 M) were tested at 15, 30, 45 and 105 min., with their modifications by (5 mg/ kg, 24 h before sacrifice) reserpine, 10–7 M propranolol, 10–8 M atropine, and 10–6 M indomethacin. Dose-response curves for adrenaline were carried out as standard protocol.¶Methods: In vitro techniques (de Jalon's solution, 31°C, carbogen, isotonic registration, re…

medicine.medical_specialtyEpinephrineMuscle RelaxationImmunologyPropranololTachyphylaxisIn Vitro TechniquesClonidineHistamine Agonistschemistry.chemical_compoundUterine ContractionDimapritInternal medicinemedicineCyclic AMPAnimalsIsotonic ContractionRats WistarTachyphylaxisPharmacologyDose-Response Relationship Drugbusiness.industryUterusEstrogensReserpineDimapritClonidineRatsAtropineDose–response relationshipEndocrinologychemistryFemalebusinessAdrenergic alpha-AgonistsHistaminemedicine.drugHistamineInflammation research : official journal of the European Histamine Research Society ... [et al.]
researchProduct

The influence of Ca2+ antagonists on the ciliary activity of the guinea pig trachea.

1990

The ciliary activity of the guinea pig tracheal respiratory epithelium was measured using a photoelectric device. Fourteen animals were administered 75 mg diltiazem/kg body weight 2 days, 1 day and 4 h prior to the investigation. Thirteen animals served as controls. In the pretreated group, the mean ciliary stroke frequency (13.4 +/- 3.0 Hz) was significantly lower (P = 0.02) than in the control group (16.6 +/- 3.7 Hz). The application of aerosolized 0.3 mmol/l nifedipine solution on the tracheal preparations of the control animals also significantly reduced the stroke frequency (P = 0.02). The ciliary activity never dropped beyond a frequency of about 8 Hz. The most probable interpretation…

medicine.medical_specialtyNifedipineGuinea PigsGuinea pigDiltiazemNifedipineInternal medicineMedicineAnimalsDiltiazemCiliaRespiratory systemVoltage-dependent calcium channelbusiness.industryCiliary activityGeneral MedicineRinger's SolutionTracheaEndocrinologymedicine.anatomical_structureOtorhinolaryngologyMucociliary ClearanceAnesthesiaRespiratory epitheliumCalciumIsotonic SolutionsbusinessRespiratory tractmedicine.drugEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery
researchProduct

Die dynamische 31-Phosphor-Magnetresonanz-Spektroskopie des M. quadriceps: Einfluß von Geschlecht und Alter auf spektroskopische Parameter

1999

PURPOSE 31P-MRS is used to assess the influence of sex und age on quadriceps muscle metabolism before and after exercise. MATERIALS AND METHODS 32 healthy volunteers (15 women, 17 men, mean age: 38 +/- 17 yrs.) were examined by dynamic phosphorus-31 (31P) magnetic resonance spectroscopy (MRS). In the magnet, the quadriceps muscle was stressed by an isometric und an isotonic form of exercise until exhaustion, respectively. RESULTS Resting conditions: With increasing subjects' age, the ratio beta-adenosine triphosphate/total phosphate decreased (r = -0.37; p = 0.02). With increasing subjects' age, the ratios inorganic phosphate/phosphocreatine (r = 0.79; p = 5 x 10(-8), phosphomonoester/beta-…

medicine.medical_specialtyQuadriceps musclePhysical exerciseIsometric exercisePhosphatePhosphocreatinechemistry.chemical_compoundEndocrinologyNuclear magnetic resonanceInorganic phosphatechemistryInternal medicineIsotonicmedicineRadiology Nuclear Medicine and imagingmedicine.symptomAcidosisRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Innovative barriers for peritoneal adhesion prevention: liquid or solid? A rat uterine horn model.

2005

Objective To compare the effects of solid barriers (PDLA membrane and foil, Interceed), innovative barrier solutions (Adept and Hyalobarrier Gel, phospholipid emulsion), and Ringer’s lactate solution in preventing postsurgical peritoneal adhesions in the rat. Design Prospective, randomized experimental study. Setting Rat model in an academic research environment. Animal(s) Female, nonpregnant Wistar rats. Intervention(s) Standardized surgical injuries were applied to the parietal and visceral peritoneum and the uterine horns. The barrier agents were applied and the wound was closed. A second-look laparoscopy was performed 31 days after surgery to assess adhesion formation. Main Outcome Meas…

medicine.medical_specialtyRinger's LactatePolymersPolyestersAdhesion (medicine)Tissue AdhesionsPeritoneal DiseasesSeverity of Illness IndexIcodextrinmedicineAnimalsHyalobarrierCellulose OxidizedAdhesion preventionLactic AcidRats WistarLaparoscopymedicine.diagnostic_testSuturesbusiness.industryUterusObstetrics and GynecologyUterine hornsAdeptMembranes ArtificialProstheses and Implantsmedicine.diseaseSurgeryRatsReproductive MedicinePeritoneal adhesionEmulsionsFemaleIsotonic SolutionsPeritoneumbusinessGelsFertility and sterility
researchProduct

Modulation of central corneal thickness by various riboflavin eyedrop compositions in porcine corneas

2012

Purpose To evaluate the modulatory effect of various riboflavin 0.1% and 0.2% compositions on the central corneal thickness (CCT) in fresh porcine corneas. Setting Department of Ophthalmology, Johannes Gutenberg University of Mainz, Mainz, Germany. Design Experimental study. Methods The CCT in freshly enucleated porcine globes was measured by ultrasound pachymetry before and after (if applicable) deepithelialization and every 10 minutes thereafter during 120 minutes of eyedrop application. In Groups 1 and 2 (controls), no eyedrops were applied. In Groups 3 and 4, isotonic riboflavin eyedrops were used. In Groups 5 to 9, hypotonic riboflavin eyedrops were given. In Groups 10 and 11, preparat…

medicine.medical_specialtySwineRiboflavinRiboflavinCorneaCorneal edemaCorneaOphthalmologyIsotonicAnimalsMedicineBody Weights and MeasuresUltrasonographyPhotosensitizing Agentsbusiness.industryCorneal EdemaOsmolar ConcentrationUltrasound pachymetryHydrogen-Ion ConcentrationSensory SystemsSurgeryOphthalmologyCross-Linking ReagentsOphthalmic solutionsmedicine.anatomical_structurePhotochemotherapySurgeryOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Statistical analysis of the relation between metallic microstructures and mechanical properties

2020

This thesis aims at the development of physical relations between the intricate 3D features of metallic microstructures and the mechanical properties of the material. For understanding which are the microstructural determinants of the resultingmechanical behaviour of metals, a deep quantitative characterisation of the microstructure is needed. The main steps of quantitative characterisation of the microstructures are: identification of the phases distribution and their chemical composition, study of the microstructure morphology (geometrical arrangement of grains, grain boundaries, grain orientations, grain size and grain shape). An accurate description of the microstructure features enrich…

statistics metal microstructures mechanical properties digital twin isotonic regression hypothesis testing simulations
researchProduct