Search results for "LAP"
showing 10 items of 3898 documents
Técnicas reconstructivas tras amputación abdominoperineal extraelevadora del recto o exenteración pélvica: mallas, plastias y colgajos
2014
Perineal wound complications after abdomino-perineal rectal resection are frequent and clinically relevant for their impact on the length of hospitalization, costs, patients' quality of life and oncologic results. With the diffusion of the preoperative radiotherapy and the gradual shift to the extra-elevator technique, the perineal morbidity rate has increased. Many series describing different techniques of primary closure of the perineal defect have been published, but high-quality clinical studies, indicating which is the best option, are missing. A biologic mesh, associated if possible to an omentoplasty, seems to be sufficient to close the perineal defect after extra-elevator abdomino-p…
Onkoplastische Sofortrekonstruktions-Technik unter Erhalt des Mamillen-Areola-Komplexes nach radikaler Resektion eines Mammakarzinoms mit zentralem S…
2001
There are few breast-conserving therapies (BCT) for centrally located breast cancer. The present paper describes a BCT for breast cancers in such a location, which permits conservation of the nipple-areola complex (NAC), provided this has not been infiltrated. After histological detection of the breast cancer by punch biopsy, a central segmental mastectomy and an axillary dissection are performed. An immediate reconstruction of the subareolar defect is carried out by means of a local flap technique, thus conserving the NAC.
Serum markers for early detection of patients with mesenteric ischemia after cardiac surgery
2018
AbstractObjectiveMesenteric ischemia (MESI) is a rare but often fatal complication in patients after cardiac surgery. Non-specific clinical symptoms and lack of specific laboratory parameters complicate the diagnosis. We evaluated potential serum markers for MESI in cardiac surgery patients.MethodsBetween March and October 2012, serial serum samples of 567 elective cardiac surgery patients were collected 1, 24, and 48 h after the operation, and concentrations of potential markers for MESI [α-glutathione-S-transferase (αGST), intestinal fatty-acid-binding protein (iFABP), and D-lactate] were measured retrospectively. In patients requiring laparotomy, blood samples obtained 72, 48, 24, and 12…
The anatomic basis of the transversus and rectus abdominis musculoperitoneal (TRAMP) composite flap
1999
The aim of this study was to provide an anatomic basis for the transversus and rectus abdominis musculoperitoneal (TRAMP) flap, recently successfully introduced for vulvovaginal reconstruction. In 25 cadavers the width and length of the portions of rectus and transversus abdominis muscles suitable for the TRAMP flap as well as the length and diameter of the inferior epigastric artery were assessed. The mean length of the rectus abdominis muscle was 32.42±0.48 cm and its width 6.15±0.12 cm. The suitable part of the transversus abdominis muscle measured 19.08±0.3 cm mean length with a mean width of 18.62±0.19 cm. No significant left-right differences were observed. The resulting area of the r…
Complications and Solutions in Propeller Flap Surgery
2020
AbstractPropeller perforator flaps (PPFs) have long been proven as valid reconstructive tools for a wide range of soft tissue defects in different body regions. During the last decade, despite their numerous advantages, many authors have thoroughly analyzed outcomes of these flaps, sometimes discouraging their use mainly because of a high failure rate. Accurate patient selection, adequate preoperative planning, and an appropriate dissection technique seem to potentially improve outcomes. Our study provides a review of the relevant literature related to PPF complications and of our experience, describing reasons for failure, measures for preventing them, and approaches for a prompt evaluatio…
Oral Surgical Management of Bone and Soft Tissues in MRONJ Treatment: A Decisional Tree.
2020
Background: The aim of the present work was to analyze a 10-year retrospective series of surgically treated medication-related osteonecrosis of the jaws (MRONJ) cases, reporting the clinical outcome and success rate for each adopted procedure in order to draw a treatment algorithm that is able to standardize clinical decision making and maximize the success of oral surgical treatment of MRONJ. Methods: Different surgical approaches were categorized taking into consideration two variables a) hard tissue management (defined as debridement, saucerization or marginal resective surgery of maxillary necrotic bone) and b) soft tissue management (defined as type of flap design and related modality …
First-in-man permanent laparoscopic fixation free obliteration of inguinal hernia defect with the 3D dynamic responsive implant ProFlor-E®. Case repo…
2020
Abstract Introduction In the case of inguinal hernia recurrence after primary anterior repair, international guidelines strongly suggest a posterior laparoscopic approach. The 3D dynamic-responsive prosthesis for inguinal hernia repair ProFlor-E® has recently been introduced to the market. The present report describes the results of the first-in-man laparoscopic inguinal hernia repair carried out with ProFlor-E®. Presentation of case A 71-year-old male Caucasian presented with recurrent inguinal hernia after primary anterior repair. A fixation free TAPP procedure with ProFlor-E® was planned. Implant delivery and placement to obliterate the defect was quick and safe. Postoperatively, startin…
Accuracy of SCORTEN and ABCD‐10 to predict mortality and the influence of renal function in Stevens–Johnson syndrome/toxic epidermal necrolysis
2020
Epidermal necrolysis (EN) compromises a spectrum of life-threatening dermatoses (Stevens-Johnson Syndrome [SJS], overlap syndrome and toxic epidermal necrolysis [TEN]). Currently, no active therapeutic regimen with unequivocal benefit exists for SJS/TEN. SCORTEN is the widely-used prognostic scale specific for SJS/TEN. Nevertheless, a new prognostic scale, the ABCD-10, has been recently proposed. In this context, acute renal failure (ARF) seems to be an important comorbidity that could influence prognosis in SJS/TEN patients more than it is assumed by these two scales. Our objectives were to compare the accuracy of the SCORTEN and ABCD-10 scales in predicting the mortality in SJS/TEN, and t…
Top-cited articles in cerebrospinal fluid leak (rhinorrhea and otorrhea) (1945–2018)
2021
Abstract Introduction: As scientific knowledge has grown in biomedicine, it has also become necessary to develop tools to manage and understand the body of evidence. In that sense, bibliometrics has become a consolidated discipline for analyzing scientific activity, enabling the characterization of a particular field or area of knowledge by means of the quantification of the bibliographic characteristics of scientific publications. Objective: The objective of this study was to determine the most frequently cited articles in the field of cerebrospinal fluid rhinorrhea and otorrhea. Methods: The searches took place on the Clarivate Analytics Web of Science platform, which includes the MEDLINE…
Innovative barriers for peritoneal adhesion prevention: liquid or solid? A rat uterine horn model.
2005
Objective To compare the effects of solid barriers (PDLA membrane and foil, Interceed), innovative barrier solutions (Adept and Hyalobarrier Gel, phospholipid emulsion), and Ringer’s lactate solution in preventing postsurgical peritoneal adhesions in the rat. Design Prospective, randomized experimental study. Setting Rat model in an academic research environment. Animal(s) Female, nonpregnant Wistar rats. Intervention(s) Standardized surgical injuries were applied to the parietal and visceral peritoneum and the uterine horns. The barrier agents were applied and the wound was closed. A second-look laparoscopy was performed 31 days after surgery to assess adhesion formation. Main Outcome Meas…