Search results for "LIMIT"

showing 10 items of 2826 documents

Ion mobility spectrometry as a fast analytical tool in benzalkonium chloride homologs determination.

2017

Abstract A novel procedure is proposed for the determination by ion mobility spectrometry (IMS) of C 12 , C 14 and C 16 benzalkonium chloride (BAC) homologs. The proposed method requires minimum sample treatment and the measurement was made in less than one minute. A high sensitivity was obtained for BAC determination by IMS with limit of detection values from 37 to 69 µg L −1 . Accuracy of the proposed methodology was evaluated through the analysis of aqueous and alcoholic samples spiked with BAC at concentration levels from 0.002% to 20% (w/v), providing recovery values from 91% to 104%. BAC was determined in sanitary alcohols, nasal sprays, postharvest products, algaecides, and treated s…

Detection limitAqueous solutionChromatographyChemistryIon-mobility spectrometry010401 analytical chemistryAnalytical chemistry010501 environmental sciences01 natural sciencesSwimming pool water0104 chemical sciencesAnalytical ChemistryBenzalkonium chloridemedicineBAC determination0105 earth and related environmental sciencesmedicine.drugTalanta
researchProduct

Sequential injection analysis for benzophenone-4 and phenylbenzimidazole sulphonic acid in sunscreen sprays by solid-phase extraction coupled with ul…

2002

Abstract A sequential injection UV method was developed to determine benzophenone-4 (BZ4) and phenylbenzimidazole sulphonic acid (PBS) simultaneously, these being the most commonly used UV-filters in aqueous formulations used as sunscreen sprays. The selective elution of both was performed by on-line solid-phase extraction, by retention on a SAX microcolumn and separation by varying the pH of elution. The sensitivity obtained was 0.042±0.001 ml μg −1 for PBS and 0.0159±0.0003 ml μg −1 for BZ4. The limit of detection was 1.6 μg ml −1 for PBS and 0.6 μg ml −1 for BZ4. The R.S.D. of the results was 1–6% for PBS and 1–12% for BZ4. The method was validated using commercial sunscreen formulations…

Detection limitAqueous solutionChromatographyElutionExtraction (chemistry)Mass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundchemistryReagentBenzophenoneEnvironmental ChemistrySolid phase extractionSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of 129I/127I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell

2003

The determination of I-129 in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe-129(+)), possible (IH2+)-I-127 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I-129/I-127 isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope ratio measurements in aqueous solutions and contaminated soil samples directly without sample preparation using ICP-MS with a hexapole collision cell (ICP-CC-QMS) was developed. Oxygen is used as reaction and carrier gas for iodine thermal desorption via the gas phase from solid…

Detection limitArgonAnalytical chemistryThermal desorptionchemistry.chemical_elementMass spectrometryAnalytical ChemistryJchemistryImpurityDesorptionddc:540Sample preparationInductively coupled plasma mass spectrometrySpectroscopy
researchProduct

2017

Abstract. Hydroxyl (OH) radical reactivity (kOH) has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide rang…

Detection limitAtmospheric Science010504 meteorology & atmospheric sciencesChemistryAnalytical chemistry010501 environmental sciences01 natural sciencesAtmospheric simulationAtmosphereAtmospheric measurements13. Climate actionReactivity (chemistry)Nitrogen oxides0105 earth and related environmental sciencesAtmospheric Measurement Techniques
researchProduct

Determination of n-alkanes, polycyclic aromatic hydrocarbons and hopanes in atmospheric aerosol: evaluation and comparison of thermal desorption GC-M…

2019

Organic aerosol (OA) constitutes a large fraction of fine particulate matter (PM) in the urban air. However, the chemical nature and sources of OA are not well constrained. Quantitative analysis of OA is essential for understanding the sources and atmospheric evolution of fine PM, which requires accurate quantification of some organic compounds (e.g., markers). In this study, two analytical approaches, i.e., thermal desorption (TD) gas chromatography mass spectrometry (GC-MS) and solvent extract (SE) GC-MS, were evaluated for the determination of n-alkanes, polycyclic aromatic hydrocarbons (PAHs) and hopanes in ambient aerosol. For the SE approach, the recovery obtained is 89.3 %–101…

Detection limitAtmospheric Science010504 meteorology & atmospheric sciencesCorrelation coefficientlcsh:TA715-787Chemistrylcsh:Earthwork. FoundationsThermal desorptionCoal combustion productsFraction (chemistry)Repeatability010501 environmental sciences01 natural scienceslcsh:Environmental engineeringAerosolEnvironmental chemistrylcsh:TA170-171Gas chromatography–mass spectrometry0105 earth and related environmental sciencesAtmospheric Measurement Techniques
researchProduct

Bromine speciation in volcanic plumes: new in situ derivatization LC-MS method for the determination of gaseous hydrogen bromide by gas diffusion den…

2020

The chemical characterization of volcanic gas emissions gives insights into the interior of volcanoes. Monitoring of BrO/SO2-ratios has recently been correlated with changes in the activity of a volcano. BrO and SO2 can both be measured autonomously and simultaneously with the same instruments from a safe distance, making their ratio potentially a strong monitoring tool. However, BrO is not a primary emitted volcanic volatile and there exist still uncertainties about the formation of BrO in volcanic plumes, mostly due to the lack of analytical approaches for the accurate speciation of certain key compounds. This study describes a new method for the determination of the BrO precursor, the ga…

Detection limitAtmospheric ScienceBromine010504 meteorology & atmospheric sciencesElectrospray ionizationDiffusionTA715-787Analytical chemistrychemistry.chemical_elementEnvironmental engineeringTA170-17101 natural sciencesPlumechemistry.chemical_compoundchemistryEarthwork. FoundationsBromideGaseous diffusionDerivatization0105 earth and related environmental sciences
researchProduct

2009

Abstract. Systematic laboratory experiments were performed to investigate quantification of various species with two versions of the Aerodyne Aerosol Mass Spectrometer, a Quadrupole Aerosol Mass Spectrometer (Q-AMS) and a compact Time-of-Flight Aerosol Mass Spectrometer (c-ToF-AMS). Here we present a new method to continuously determine the detection limits of the AMS analyzers during regular measurements, yielding detection limit (DL) information under various measurement conditions. Minimum detection limits range from 0.03 μg m−3 (nitrate, sulfate, and chloride) up to 0.5 μg m−3 (organics) for the Q-AMS. Those of the c-ToF-AMS are found between 0.003 μg m−3 (nitrate, sulfate) and 0.03 μg …

Detection limitAtmospheric Sciencechemistry.chemical_compoundNitratechemistryAnalytical chemistryMass concentration (chemistry)SulfateContaminationMass spectrometryAerosolIonAtmospheric Measurement Techniques
researchProduct

Improvement of the atomic fluorescence determination of mercury by using multicommutation

2002

Atomic fluorescence spectrometry (AFS) determination of Hg has been improved by exploiting the possibilities of the multicommutation approach in order to outline a fully mechanised system which supplies the same sensitivity as the use of continuous measurements, reducing drastically the reagents consumed and waste generation. The use of multicommutation with a simultaneous reduction of the liquid–gas separator volume and the insertion point modification of argon transport gas provides a sensitivity of the AFS measurements of 300 mV ng−1 ml (using a full scale of 1000 mV), a limit of detection (3 s) of 1.3 ng l−1 and relative standard deviation values below 0.1% for 10 independent measuremen…

Detection limitAtomic fluorescenceChromatographyArgonChemistryRelative standard deviationAnalytical chemistrychemistry.chemical_elementSeparator (oil production)Analytical ChemistryMercury (element)Waste generationReagentSpectroscopyJ. Anal. At. Spectrom.
researchProduct

Silver based sensors from CD for chloride ions detection

2021

This preliminary work shows a new and innovative way to produce silver based electrodes from compact discs and its application towards the detection of chloride ions. A complete sensor was obtained from the compact discs with working, reference and counter electrode made of silver. Chloride ions were detected by exploiting the high affinity of silver with this anion to produce silver chloride. This electrochemical oxidation of silver can be monitored by using an electrochemical technique such as linear scan voltammetry. Indeed, during linear scan voltammetry the oxidation of silver to silver chloride lead to a peak current that increases linearly with chloride concentration. Using this tech…

Detection limitAuxiliary electrodevoltammetryMaterials scienceInorganic chemistrycircular economyelectrochemical sensorElectrochemistryChloride ions electrochemical sensor voltammetry circular economyChlorideIonSilver chloridechemistry.chemical_compoundchemistryElectrodemedicineChloride ionsVoltammetrymedicine.drug
researchProduct

Bioanalysis of digoxin and its metabolites using direct serum injection combined with liquid chromatography and on-line immunochemical detection.

1994

Abstract An automated dual-column liquid chromatographic assay for digoxin is described. Serum samples are directly injected onto a restricted-access solid-phase extraction support. After liquid chromatographic (LC) separation on a C18 analytical column, antigenic analytes are detected by means of post-column immunochemical detection (ICD) using fluorescein-labelled antibodies against digoxigenin. The detection limit of this assay is 160 pg/ml (preconcentration of 1.0 ml serum). With the present method digoxin and three of its cross-reactive metabolites were determined in serum taken from patients which were orally administered a 1-mg dose of digoxin. The results obtained with LC—ICD were c…

Detection limitBioanalysisAnalyteDigoxinChromatographyDigoxinmedicine.diagnostic_testMetaboliteImmunochemistryFluoroimmunoassayGeneral ChemistryCross Reactionschemistry.chemical_compoundchemistryImmunoassaymedicineDigoxigeninHumansQuantitative analysis (chemistry)DigoxigeninBiomarkersChromatography High Pressure Liquidmedicine.drugJournal of chromatography. B, Biomedical applications
researchProduct