Search results for "LIMIT"
showing 10 items of 2826 documents
A Fully Automated Assembly Using Solenoid Valves for the Photodegradation and Chemiluminometric Determination of the Herbicide Chlorsulfuron
2005
Abstract This paper presents a new photochemiluminescent system for the determination of chlorsulfuron in water samples. The light from a low‐pressure mercury lamp is used as a clean, reproducible, and inexpensive “reagent” for the derivation of the pesticide, performed in glycine buffer at pH 9.5. Then, the photo‐products from irradiation are oxidized by permanganate in sulfuric acid solution. The oxidation reaction was favored by using high temperatures. A comparative study and discussion about the use of polyphosphoric acid instead of sulfuric acid in the oxidation reaction is also presented. The use of solenoid valves allows for the easy, complete automation of the process with low samp…
FI-on line photochemical reaction for direct chemiluminescence determination of photodegradated chloramphenicol.
2002
Abstract A new, simple, clean and selective flow injection strategy based on the tandem photochemical reaction-chemiluminescence detection was applied to the determination of chloramphenicol. The determination is based on the on-line photodegradation of the drug in a glycine buffer at pH 8.8 by using a photoreactor consisting of 697 cm×0.5 mm PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. Photodegradated chloramphenicol is detected by direct chemiluminescence of resulting photo-fragments and their subsequent reaction with potassium permanganate in sulfuric acid medium as oxidant. The method allows the chemiluminescence determination of compounds which do not exhibit n…
Chiral separation of bupivacaine enantiomers by capillary electrophoresis partial-filling technique with human serum albumin as chiral selector
2004
Abstract Capillary electrophoresis (CE) is a powerful technique for enantiomer separations due to its intrinsic high separation efficiencies, speed of analysis, low reagent consumption and small sample requirements. However, some chiral selectors present strong background UV absorption providing high detection limits. The present paper deals with the application of the partial-filling technique to the separation of bupivacaine enantiomers by capillary electrophoresis using human serum albumin (HSA) as chiral selector. In this procedure the cationic surfactant cetyltrimethylammonium bromide (CTAB) was used as a dinamic capillary coating in order to reduce the electro-osmotic flow and detect …
On-line preconcentration strategies for analyzing pesticides in fruits and vegetables by micellar electrokinetic chromatography.
2007
Five pesticides (fludioxonil, procymidone, pyriproxyfen, dinoseb and carbendazim) were separated in reversed migration micellar electrokinetic chromatography (RM-MEKC) using 20 mmol l(-1) phosphate buffer at pH 2.3, containing 25 mmol l(-1) sodium dodecylsulfate and 10% methanol. Three on-line concentration strategies, sweeping (SW), normal stacking with reversed migration and a water plug (SRW) and stacking with reverse migration and removal of sample matrix using polarity switching (SRMM), were compared. About 10-, 30- and 50-fold increases in detection sensitivity, compared with standard hydrodynamic injection (5 s at 0.5 psi), were observed with SW, SRW and SRMM, respectively. Limits of…
Improved Solid Phase Extraction Procedure for Assay of Cephalosporins in Human Urine Samples
1998
Abstract Solid phase extraction technique has been evaluated for the treatment of urine samples in the analysis of cephalosporins before injection into an HP-Hypersil ODS-C18 column. Cephalexin, cefotaxime, cefazolin, cefuroxime, and cefoxitin were tested with seven different reversed-phase extraction column cartridges and the obtained urine extracts were not clean. However, 3M Empore extraction disk cartridges packed with octadecyl (C18) bonded silica provided clean extracts with a single extraction. The recoveries of the five cephalosporins ranged from 56 to 60 % in the 1.25–500 g/mL concentration range. The assay was accurate, precise, and adequate for testing the drug content in urine s…
Effect of the shampoo Ultra Clean on drug concentrations in human hair
2000
The influence of the special shampoo Ultra Clean (Zydot Unlimited, Tulsa, Oklahoma) on the results of hair analyses was investigated. Hair samples from persons (n = 14) with a known history of drug abuse were collected at autopsy. The hair samples were divided into separate strands which were analyzed both after washing with Ultra Clean and without treatment. Hair analyses were performed by methanol extraction under sonication, purification by solid phase extraction and GC/MS in SIM mode according to routine procedures for tetrahydrocannabinol (THC), cocaine, amphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA), methylenedioxyethylamphetamine (MDE), heroin, 6-m…
On-line in-tube solid phase microextraction-capillary liquid chromatography method for monitoring degradation products of di-(2-ethylhexyl) phthalate…
2014
Abstract The main di-(2-ethylhexyl) phthalate (DEHP) degradation products, (2-ethylhexyl) phthalate (MEHP), diethyl phthalate (DEP) and dibutyl phthalate (DBP), have been tested. The proposed cost-effective method combines on-line, in-tube solid-phase micro extraction (IT-SPME) in in-valve configuration and capillary liquid chromatography with UV diode array detection (Cap-LC-DAD). Acidification of the samples at pH 3 improved markedly the estimation of MEHP. Aliquots of 4 mL of acidified water samples were directly processed. After sample loading, the analytes were desorbed with the mobile-phase and transferred to the monolithic capillary column. Satisfactory linearity and precision, absen…
Simple and commercial readily-available approach for the direct use of ionic liquid-based single-drop microextraction prior to gas chromatography
2009
A simple and commercial readily-available approach that enables the direct use of ionic liquid (IL)-based single-drop microextraction (SDME) prior to gas chromatography (GC) is presented. The approach is based on thermal desorption (TD) of the analytes from the IL droplet to the GC system, by using a robust and commercially-available thermodesorption system. For this purpose, a two-glass-tube concentrically disposed system was designed. The inner tube is a laboratory-cut Pyrex tube (20mm length) that houses the ionic liquid droplet from the SDME process, and the outer tube is a commercially-available TD glass tube (187 mm length) commonly employed for stir-bar sorptive extractions (SBSE). I…
RAPID LIQUID CHROMATOGRAPHIC DETERMINATION OF TETRACYCLINES IN ANIMAL FEEDS USING A SURFACTANT SOLUTION AS MOBILE PHASE
2002
ABSTRACT A chromatographic procedure was developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), doxycycline (DC) and minocycline (MINO) in animal feeds. Clear analyte-rich extracts were obtained using a 1 : 1 acetonitrile/water mixture buffered at pH 3. The extracts were injected into a conventional unprotected C18 chromatographic column and eluted with a mobile phase of 0.05 M sodium dodecyl sulfate/5% 1-butanol/0.01 M oxalic acid at pH 3. Good resolution was achieved for the five compounds, whereas OTC and TC coeluted with an optimized aqueous-organic mobile phase of methanol/acetonitrile/0.01 M oxalic acid at pH 3. Mean recoveries from spike…
A solid-phase extraction and size-exclusion liquid chromatographic method for polyethylene glycol 25 p-aminobenzoic acid determination in urine: Vali…
2007
No previous publications about percutaneous absorption of polyethylene glycol 25 p-aminobenzoic acid (PEG-25 PABA) have been found in the literature and the expected levels to be found in human urine after sunscreens use are unknown. The method proposed here is suitable to determine PEG-25 PABA in the urine of sunscreens users in order to carry out studies on body accumulation/excretion. It is based on solid-phase extraction (SPE) with size-exclusion liquid chromatography determination. Solid-phase extraction allows the analyte to be retained and subsequently eluted for a clean-up, using a silica-based cartridge. The size-exclusion liquid chromatography of the eluted allows the rest of matr…