Search results for "Least-Squares Analysi"

showing 10 items of 66 documents

Microalbuminuria fractional clearance and early renal permselectivity changes in essential hypertension.

1992

In order to verify if, in essential hypertension (EH), the microalbuminuria (AER) increase could be due to hemodynamic modifications or to glomerular structural changes, in 15 essential hypertensives (EHs) with 24-hour AER16 micrograms/min and in 15 EHs with 24-hour AERor = 16 micrograms/min, the day- and nighttime behavior of creatinine clearance (Ccr), as well as AER clearance (AER-C) and fractional clearance (AER-FC), and behavior of blood pressure (BP) was evaluated. Patients with 24-hour AER16 micrograms/min showed significantly higher values of 24-hour and daytime Ccr than the other group of EHs, while during the night period, there were no significant differences between the two grou…

Adultmedicine.medical_specialtyanimal structuresCell Membrane Permeabilityendocrine system diseasesRenal functionHemodynamicsurologic and male genital diseasesEssential hypertensionKidneyNephropathyInternal medicinemedicineAlbuminuriaHumansLeast-Squares AnalysisProteinuriabusiness.industryAlbuminmedicine.diseasefemale genital diseases and pregnancy complicationsBlood Pressure MonitorsCircadian RhythmBlood pressureEndocrinologyNephrologyHypertensionMicroalbuminuriamedicine.symptombusinesshuman activitiesGlomerular Filtration RateAmerican journal of nephrology
researchProduct

Simultaneous spectrophotometric determination of calcium and magnesium in mineral waters by means of multivariate partial least-squares regression.

1997

A method for simultaneous spectrophotometric determination of calcium and magnesium in mineral waters using multivariate calibration methods is proposed. The method is based on the development of the reaction between the analytes and Methylthymol Blue at pH 11. Two operational modes were used: static (spectral information) and flow injection (FI) (spectral and kinetic information). The selection of variables was studied. A series of synthetic solutions containing different concentrations of calcium and magnesium were used to check the prediction ability of the partial least-squares models. The method was applied to the analysis of mineral waters and the results were compared with those obta…

AnalyteMultivariate statisticsAnalytical chemistrychemistry.chemical_elementCalciumBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundSpectrophotometryPartial least squares regressionElectrochemistrymedicineEnvironmental ChemistryMagnesiumLeast-Squares AnalysisSpectroscopyMineralmedicine.diagnostic_testMagnesiumchemistrySpectrophotometryMultivariate AnalysisCalciumMineral WatersTriarylmethane dyeThe Analyst
researchProduct

Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis

2010

Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…

AnalyteResolution (mass spectrometry)Adrenergic beta-AntagonistsStatistics as TopicAnalytical chemistryEnvironmentHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceRiversSCIENCE BASED CALIBRATIONSample preparationLeast-Squares AnalysisElectrodesChromatography High Pressure LiquidAnalgesicsENVIRONMENTAL ANALYSISChromatographyChemistryOtras Ciencias QuímicasExtraction (chemistry)Ciencias QuímicasDrug ResiduesStandard curveHIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION (HPLC-DAD)CalibrationMultivariate AnalysisEnvironmental PollutantsCIENCIAS NATURALES Y EXACTAS
researchProduct

Modified locally weighted—Partial least squares regression improving clinical predictions from infrared spectra of human serum samples

2012

Locally weighted partial least squares regression (LW-PLSR) has been applied to the determination of four clinical parameters in human serum samples (total protein, triglyceride, glucose and urea contents) by Fourier transform infrared (FTIR) spectroscopy. Classical LW-PLSR models were constructed using different spectral regions. For the selection of parameters by LW-PLSR modeling, a multi-parametric study was carried out employing the minimum root-mean square error of cross validation (RMSCV) as objective function. In order to overcome the effect of strong matrix interferences on the predictive accuracy of LW-PLSR models, this work focuses on sample selection. Accordingly, a novel strateg…

Blood GlucoseAnalyteChemistryBlood ProteinsCross-validationAnalytical ChemistryChemometricsMatrix (chemical analysis)symbols.namesakeFourier transformSpectroscopy Fourier Transform InfraredPartial least squares regressionPrincipal component analysisStatisticssymbolsHumansUreaLeast-Squares AnalysisFourier transform infrared spectroscopyBiological systemTriglyceridesTalanta
researchProduct

Influence of different biomaterials on the viability of Aggregatibacter actinomycetemcomitans

2011

Abstract Objectives The aim of the present in vitro study was to evaluate the effects of different biomaterials used for regenerative periodontal surgery on the growth of the periodontopathogen Aggregatibacter actinomycetemcomitans . Methods Three commercially available biomaterials of synthetic origin (hydroxyapatite/beta-tricalcium phosphate, nanostructured hydroxyapatite paste, oily calcium hydroxide suspension), a bovine-derived xenograft as well as an enamel matrix derivative (EMD) were added in different concentrations to calibrated suspensions of A. actinomycetemcomitans ATCC 43718/33384 (serotype b/c). Equal aliquots (0.1 ml) for the viability assay were taken after 5 min, 1 h, 3 h,…

Calcium PhosphatesBone MatrixBiocompatible MaterialsRegenerative MedicineAggregatibacter actinomycetemcomitansMicrobiologyCalcium HydroxideAgar platechemistry.chemical_compoundDental Enamel ProteinsMaterials TestingEnamel matrix derivativeAnimalsViability assayLeast-Squares AnalysisGeneral DentistryColony-forming unitMicrobial ViabilityCalcium hydroxidebiologyAggregatibacter actinomycetemcomitansCell BiologyGeneral Medicinebiology.organism_classificationAntimicrobialNanostructuresDurapatiteOtorhinolaryngologychemistryLinear ModelsCattleGrowth inhibitionArchives of Oral Biology
researchProduct

Partial least squares attenuated total reflectance IR spectroscopy versus chromatography: the greener method

2012

Method election is a complex task that must be done carefully in order to ensure the capability of analytical methodologies to provide appropriate data for problem solving. This is a real challenge in all fields, but especially with bioanalysis, which in many cases involves the need to do a large number of determinations in complex

ChromatographyBioanalysisChromatographyChemistryClinical BiochemistryInfrared spectroscopyGreen Chemistry TechnologyGeneral MedicineAnalytical ChemistryMedical Laboratory TechnologyAttenuated total reflectionSpectroscopy Fourier Transform InfraredPartial least squares regressionLeast-Squares AnalysisGeneral Pharmacology Toxicology and PharmaceuticsBioanalysis
researchProduct

Determination of lecithin and soybean oil in dietary supplements using partial least squares-Fourier transform infrared spectroscopy.

2008

Lecithin and soybean oil in dietary supplements were determined by Fourier transform infrared spectrometry transmission measurements in dichloromethane in combination with a partial least squares (PLS) regression. Two different PLS models were developed, using 16 synthetic mixtures of analytes in dichloromethane, making measurements in the spectral range from 931.8 to 1252.3 cm(-1) for lecithin and from 911.4 to 1246.9 cm(-1) and 1695.3 to 1774.5 cm(-1) for soybean oil. Seven products from the Spanish market with lecithin concentrations between 21.1% and 99.1% and soybean oil concentrations between 0% and 37.2% were analyzed by the proposed method and the data was compared to a chromatograp…

Chromatographyfood.ingredientChemistryfood and beveragesLecithinFourier transform spectroscopySoybean oilAnalytical ChemistrySoybean Oilchemistry.chemical_compoundfoodPartial least squares regressionCalibrationDietary SupplementsLecithinsSpectroscopy Fourier Transform InfraredFourier transform infrared spectrometryFourier transform infrared spectroscopyLeast-Squares AnalysisDichloromethane
researchProduct

Biopartitioning micellar chromatography to pedict mutagenicity of aromatic amines

2007

[EN] Mutagenicity is a toxicity endpoint associated with the chronic exposure to chemicals. Aromatic amines have considerable industrial and environmental importance due to their widespread use in industry and their mutagenic capacity. Biopartitioning micellar chromatography (BMC), a mode of micellar liquid chromatography that uses micellar mobile phases of Brij35 in adequate experimental conditions, has demonstrated to be useful in mimicking the drug partitioning process into biological systems. In this paper, the usefulness of BMC for predicting mutagenicity of aromatic amines is demonstrated. A multiple linear regression (MLR) model based on BMC retention data is proposed and compared wi…

Chronic exposureQuantitative structure–activity relationshipPredictive capabilityQuantitative Structure-Activity RelationshipAromatic aminesHigh-performance liquid chromatographyModels BiologicalMutagenicityDrug DiscoveryQUIMICA ANALITICAOrganic chemistryComputer SimulationAminesLeast-Squares AnalysisMicellesPharmacologychemistry.chemical_classificationChromatographyChromatographyOrganic ChemistryAromatic amineGeneral MedicineBiopartitioning micellar chromatographychemistryMicellar liquid chromatographyMutagenesisQuantitative retentione-activity relationships
researchProduct

Least-squares community extraction in feature-rich networks using similarity data

2021

We explore a doubly-greedy approach to the issue of community detection in feature-rich networks. According to this approach, both the network and feature data are straightforwardly recovered from the underlying unknown non-overlapping communities, supplied with a center in the feature space and intensity weight(s) over the network each. Our least-squares additive criterion allows us to search for communities one-by-one and to find each community by adding entities one by one. A focus of this paper is that the feature-space data part is converted into a similarity matrix format. The similarity/link values can be used in either of two modes: (a) as measured in the same scale so that one may …

Computer scienceEconomicsKernel FunctionsSocial Sciences02 engineering and technologyLeast squaresInfographicsTranslocation GeneticGeographical LocationsMedical Conditions0202 electrical engineering electronic engineering information engineeringMedicine and Health SciencesPsychologyCluster AnalysisOperator TheoryData ManagementMultidisciplinaryApplied MathematicsSimulation and ModelingQRExperimental PsychologyEuropeFeature (computer vision)Research DesignPhysical SciencesMedicine020201 artificial intelligence & image processingGraphsAlgorithmsNetwork AnalysisNetwork analysisResearch ArticleComputer and Information SciencesScienceFeature vectorScale (descriptive set theory)Research and Analysis MethodsColumn (database)Similarity (network science)020204 information systemsParasitic DiseasesLeast-Squares AnalysisFeature databusiness.industryData VisualizationBiology and Life SciencesPattern recognitionTropical DiseasesEconomic AnalysisMalariaPeople and PlacesArtificial intelligencebusinessMathematicsPLoS ONE
researchProduct

Tensor decomposition of EEG signals: A brief review

2015

Electroencephalography (EEG) is one fundamental tool for functional brain imaging. EEG signals tend to be represented by a vector or a matrix to facilitate data processing and analysis with generally understood methodologies like time-series analysis, spectral analysis and matrix decomposition. Indeed, EEG signals are often naturally born with more than two modes of time and space, and they can be denoted by a multi-way array called as tensor. This review summarizes the current progress of tensor decomposition of EEG signals with three aspects. The first is about the existing modes and tensors of EEG signals. Second, two fundamental tensor decomposition models, canonical polyadic decomposit…

Current (mathematics)canonical polyadicNeuroscience(all)Electroencephalographyevent-related potentialsSignalMatrix decompositionMatrix (mathematics)tensor decompositionDecomposition (computer science)medicineEEGTensorLeast-Squares AnalysisEvoked PotentialsMathematicsCanonical polyadicSignalQuantitative Biology::Neurons and Cognitionmedicine.diagnostic_testGeneral NeuroscienceBrainElectroencephalographySignal Processing Computer-AssistedTuckerTensor decompositiontuckeraivotFactor Analysis StatisticalsignalAlgorithmEvent-related potentialsTucker decompositionJournal of Neuroscience Methods
researchProduct