Search results for "Lens implant"
showing 10 items of 145 documents
Compression forces of haptics of freely rotating posterior chamber intraocular lenses.
1998
Abstract Purpose: To measure the compressive forces of the haptics of 28 intraocular lens (IOL) models for different modes of compression and compare the results of two types of measurements. Setting: Department of Ophthalmology, Central Hospital of Central Finland, Jyvaskyla, Finland. Methods: The haptics of 28 types of IOLs were compressed to a diameter of 9.0 mm between curved anvils. The compression forces in the plane of compression (i.e., in the plane of the optics) were measured at 0.5 mm intervals. During compression, the optics and the haptics were free to rotate with respect to the anvils. The results were compared with those of earlier measurements in which the optics were held f…
Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses
2014
Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…
Incisional Keratotomy to Toric Intraocular Lenses: An Overview of the Correction of Astigmatism in Cataract and Refractive Surgery
2003
Contrast sensitivity and color perception with orange and yellow intraocular lenses
2012
To evaluate contrast sensitivity function (CSF) and color vision after implantation of either orange or yellow-tinted intraocular lenses (IOLs).Fifty-six eyes of 28 cataract patients who had bilateral implantation of orange-tinted (PC440Y Orange, Ophtec), yellow-tinted (AcrySof Natural SN60AT, Alcon), or clear (AcrySof SA60AT, Alcon) IOLs were examined. Six months postoperatively, monocular CSF under photopic and mesopic (with and without glare) conditions were measured using the Functional Visual Analyzer. Color discrimination was determined with the Farnsworth-Munsell 100-Hue test.Patients implanted with orange-tinted, yellow-tinted, or clear IOLs displayed similar CSF values, with no sta…
Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.
2019
To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…
A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma
2014
Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…
European study of the efficacy of a cross-linked gel stent for the treatment of glaucoma
2020
indexation en cours.; PURPOSE: This study investigated the efficacy and safety of a cross-linked collagen stent (XEN 45) with or without cataract surgery in the treatment of glaucoma. SETTING: Real-life setting. DESIGN: Prospective, open-label, multicenter clinical trial. METHODS: Eligible patients with glaucoma inadequately controlled by treatment, or poor compliance or intolerance to topical therapy were included. Patients were divided into those with implant only (solo group; phakic and pseudophakic patients) and implant combined with cataract surgery (combo group). Differences in average intraocular pressure (IOP) and number of medications between baseline and study end (12 months), and…
Posterior‐chamber phakic implantable collamer lenses with a central port: a review
2020
Abstract We aimed to summarize the outcomes reported following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc) for myopia correction. A literature search in PubMed, Web of Science and Scopus was carried out to identify publications reporting clinical outcomes of patients who were implanted with the V4c ICL model and had a follow‐up period of at least 6 months. A total of 35 clinical studies published between 2012 and 2020 were included in the present review. A comprehensive analysis of the available data was performed, focusing on visual and refractive outcomes at different time‐points post‐surgery. In addition, adverse events and other pa…
Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses
2013
Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…
Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens
2009
Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …