Search results for "Libration"

showing 10 items of 901 documents

Controlling false match rates in record linkage using extreme value theory

2011

AbstractCleansing data from synonyms and homonyms is a relevant task in fields where high quality of data is crucial, for example in disease registries and medical research networks. Record linkage provides methods for minimizing synonym and homonym errors thereby improving data quality. We focus our attention to the case of homonym errors (in the following denoted as ‘false matches’), in which records belonging to different entities are wrongly classified as equal. Synonym errors (‘false non-matches’) occur when a single entity maps to multiple records in the linkage result. They are not considered in this study because in our application domain they are not as crucial as false matches. Fa…

Data cleansingData cleansingBiomedical ResearchDatabases FactualCalibration (statistics)Computer scienceHealth Informaticscomputer.software_genrePlot (graphics)Mean excess plotStatisticsRegistriesExtreme value theoryLinkage (software)Models StatisticalComputational BiologyFellegi–Sunter modelMixture modelGeneralized Pareto distributionComputer Science ApplicationsData qualityStatistics of extreme valuesDatabase Management SystemsMedical Record LinkageData miningcomputerAlgorithmsMedical InformaticsRecord linkageJournal of Biomedical Informatics
researchProduct

Sun Induced Fluorescence Calibration and Validation for Field Phenotyping

2018

Reliable measurements of Sun Induced Fluorescence (SIF) require a good instrument characterization as well as a complex processing chain. In this paper, we summarize the state of the art SIF retrieval methods and measurements platforms for field phenotyping. Furthermore, we use HyScreen, hyperspectral-imaging system for top of canopy measurements of SIF, as an example of the instrument requirements, data process, and data validation needed to obtain reliable measurements of SIF.

Data processingAnd field spectrometerCalibration and validationRetrievals method010504 meteorology & atmospheric sciencesField (physics)FIS/06 - FISICA PER IL SISTEMA TERRA E PER IL MEZZO CIRCUMTERRESTREComputer scienceSun Induced fluorescenceGEO/12 - OCEANOGRAFIA E FISICA DELL'ATMOSFERAData validationHyperspectral measurement010501 environmental sciences01 natural sciencesReflectivityFluorescenceField phenotyping0105 earth and related environmental sciencesRemote sensingIGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium
researchProduct

Industrial Environment Mapping Using Distributed Static 3D Sensor Nodes

2018

This paper presents a system architecture for mapping and real-time monitoring of a relatively large industrial robotic environment of size 10 m × 15 m × 5 m. Six sensor nodes with embedded computing power and local processing of the 3D point clouds are placed close to the ceiling. The system architecture and data processing is based on the Robot Operating System (ROS) and the Point Cloud Library (PCL). The 3D sensors used are the Microsoft Kinect for Xbox One and point cloud data is collected at 20 Hz. A new manual calibration procedure is developed using reflective planes. The specified range of the used sensor is 0.8 m to 4.2 m, while depth data up to 9 m is used in this paper. Despite t…

Data processingComputer scienceReal-time computingPoint cloud0102 computer and information sciences02 engineering and technologyCeiling (cloud)01 natural sciences020202 computer hardware & architecture010201 computation theory & mathematics0202 electrical engineering electronic engineering information engineeringBenchmark (computing)Systems architectureCalibrationMetreReflection mapping2018 14th IEEE/ASME International Conference on Mechatronic and Embedded Systems and Applications (MESA)
researchProduct

Determination of quality parameters of beers by the use of attenuated total reflectance-Fourier transform infrared spectroscopy

2005

Abstract The estimation of important quality parameters of beers, such as original and real extracts and alcohol content, has been evaluated by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial least square (PLS) calibration approach. Two sample populations, one consisting of 24 samples and other of 21 samples, obtained from the Spanish market and covering different types of beer were used. The first set was used for building and validating the model, whereas the second, measured 6 months after, was used for evaluating its robustness. The spectral range and the size of the calibration set and its suitability for building the PLS model have been …

Data setChemistryAttenuated total reflectionStatisticsAnalytical chemistryCalibrationInfrared spectroscopySample preparationFourier transform infrared spectroscopyStandard deviationFourier transform spectroscopyAnalytical ChemistryTalanta
researchProduct

Building energy performance forecasting: A multiple linear regression approach

2019

Abstract Different ways to evaluate the building energy balance can be found in literature, including comprehensive techniques, statistical and machine-learning methods and hybrid approaches. The identification of the most suitable approach is important to accelerate the preliminary energy assessment. In the first category, several numerical methods have been developed and implemented in specialised software using different mathematical languages. However, these tools require an expert user and a model calibration. The authors, in order to overcome these limitations, have developed an alternative, reliable linear regression model to determine building energy needs. Starting from a detailed …

Decision support systemComputer scienceCalibration (statistics)020209 energy02 engineering and technologyManagement Monitoring Policy and LawBuilding energy demandsymbols.namesake020401 chemical engineeringLinear regression0202 electrical engineering electronic engineering information engineeringSensitivity (control systems)0204 chemical engineeringReliability (statistics)Multiple linear regressionSettore ING-IND/11 - Fisica Tecnica AmbientaleMechanical EngineeringBuilding and ConstructionIndustrial engineeringPearson product-moment correlation coefficientDynamic simulationIdentification (information)Black box methodGeneral EnergysymbolsForecast methodSensitivity analysisDynamic simulation
researchProduct

Determination of Phenol by Preconcentration‐Direct Chemiluminescence in a FIA Assembly

2005

Abstract The determination of phenol in water samples is proposed with the aid of a flow‐injection system. The analytical procedure is based on the direct chemiluminometric emission by oxidation of the analyte with potassium permanganate in acidic medium. The flow assembly is provided with a solid‐phase reactor filled with a resin type XAD‐4 for analyte preconcentration. A large study of potential interferences, namely, amino acids reaching water through degradation of organic matter; metals and inorganic metal ions typically present in water interfering with the CL emission of the parent compound, was performed. The calibration graph was linear over the phenol concentration range 1.0–20.0 …

Detection limitAnalyteChemistryCalibration curveMetal ions in aqueous solutionBiochemistry (medical)Clinical BiochemistryInorganic chemistryBiochemistryAnalytical Chemistrylaw.inventionStandard curvePotassium permanganatechemistry.chemical_compoundlawElectrochemistryPhenolSpectroscopyChemiluminescenceAnalytical Letters
researchProduct

Photo‐Induced Chemiluminometric Determination of Acrolein in a Multicommutation Flow Assembly

2007

Abstract This paper deals with the determination of acrolein based on a strategy provided with a sensitive detection, the chemiluminescence; a “clean chemical” analyte treatment, the on‐line UV‐irradiation; and, a simple and quick automated system, the emergent multicommutation continuous‐flow methodology. The pesticide solution is irradiated (stopped‐flow) for 30 s; then, the resulting solution is introduced to the flow‐cell after being alternated with segments of the stream formed by potassium permanganate in strong acid solution and ethanol segments. The calibration range, from 1 to 1 mg l−1, resulted in a linear behavior over the range 5–100 µg l−1 and fitting the linear equation: I=75.…

Detection limitAnalyteChromatographyCorrelation coefficientBiochemistry (medical)Clinical BiochemistryFlow (psychology)AcroleinAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionPotassium permanganatechemistry.chemical_compoundchemistrylawElectrochemistryCalibrationSpectroscopyChemiluminescenceAnalytical Letters
researchProduct

Selection of calibration set samples in determination of olive oil acidity by partial least squares–attenuated total reflectance–Fourier transform in…

2003

Abstract A chemometric method has been applied for the determination of the free fatty acid (FFA) concentration in commercial olive oil samples of different types an origins by using Fourier transform infrared spectroscopy (FTIR) attenuated total reflectance (ATR) measurements. Different methods for selecting the training set, including hierarchical cluster analysis, were applied and compared. The prediction capabilities of partial least squares (PLS) multivariate calibration methods, net analyte signal (NAS) preprocessing followed by PLS or classical least squares (CLS) regression method of ATR–FTIR data were evaluated. Several aspects, like spectral range to be considered, different prepr…

Detection limitAnalyteMean squared errorChemistryAnalytical chemistryBiochemistryFourier transform spectroscopyStandard deviationAnalytical ChemistryChemometricsPartial least squares regressionCalibrationEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

Determination of carbonates in waters by on-line vapor generation FTIR

1998

Abstract An electrically heated gas-permeation unit (GPU) has been employed for the vapor-generation Fourier transform infrared (FTIR) determination of total carbonate in waters. The developed method is based on the simultaneous injection of 100 μ l sample and 100 μ l nitric acid in a two-channel manifold with a merging zone, which provides the generation of CO 2 through the GPU, heated at 90°C, from which CO 2 is swept by a stream of N 2 to a long-path infrared gas cell. Absorbance measurements were made in the range from 2500 to 2150 cm −1 and the corresponding flow injection recordings were obtained as a function of time. The areas of these peaks are interpolated in a calibration equatio…

Detection limitAqueous solutionChemistryInfraredAnalytical chemistryAbsorbancechemistry.chemical_compoundsymbols.namesakeFourier transformNitric acidCalibrationsymbolsFourier transform infrared spectroscopySpectroscopyVibrational Spectroscopy
researchProduct

Flow spectrophotometric determination of ammonium ion

1999

Abstract A flow procedure is proposed for the determination of ammonium ion. The sample in basic medium is forced through a solid-phase reactor containing immobilized AgCl on polymeric pearl beads. The released Ag + , complexed with the ammonia, gives a blue ternary complex with the aid of bromopyrogallol red and 1,10-phenanthroline which is spectrophotometrically monitored at 636 nm. The calibration graph is linear over the range 1–20 μg ml −1 ammonium ion, detection limit ( s / n  = 3)  0.35 μg ml −1 and relative standard deviation (slope) 1.9 % ( n  = 7). The sample throughput is 48 h −1 . The influence of foreign compounds is studied and the procedure is applied to ammonium ion determi…

Detection limitBromopyrogallol redChemistryCalibration curveAnalytical chemistryBiochemistryAnalytical ChemistryIonAmmoniachemistry.chemical_compoundSilver chlorideEnvironmental ChemistryAmmoniumTernary complexSpectroscopyNuclear chemistryAnalytica Chimica Acta
researchProduct