The fast readout system for the MAPMTs of COMPASS RICH-1
2007
A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultiplie…
High Precision Momentum Calibration of the Magnetic Spectrometers at MAMI for Hypernuclear Binding Energy Determination
2016
We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency photomultiplier tube, is considered as the high-resolution and highly stable TOF detector. By means of Monte Carlo simulations it is demonstrated that the magnetic spectrometers at the MAMI electron-scattering facility can be calibrated absolutely with an accuracy $\delta p/p\leq 10^{-4}$, which w…
Characterisation and calibration of a scintillating fibre detector with > 4000 multi-anode photomultiplier channels
2012
In the Kaos spectrometer at the Mainz Microtron a high-resolution coordinate detector for high-energy particles is operated. It consists of scintillating fibres with diameters of 4000 multi-anode photomultiplier channels. It is one of the most modern focal-plane detectors for magnetic spectrometers world-wide. To correct variations in the detection efficiency, caused by the different gains and the different optical transmittances, a fully automated off-line calibration procedure has been developed. The process includes the positioning of a radioisotope source alongside the detector plane and the automated acquisition and analysis of the detector signals. It was possible to characterise and …
Pattern recognition and PID for COMPASS RICH-1
2008
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure and algorithms, and the detector characterization and PID results.
The COMPASS RICH-1 fast photon detection system
2008
Abstract A fast photon detection system has been built as a part of the upgrade of the COMPASS RICH-1 detector: it is based on 576 multi-anode photomultiplier tubes (MAPMTs) coupled to individual fused silica lens telescopes and fast readout electronics. This system has replaced the MWPCs with CsI photo-cathodes in the central region ( 1.3 m 2 , 25% of the total area) of the COMPASS RICH-1 photon detectors and has successfully been operated during the data taking in 2006 and 2007. We report about the fast photon detection system design, construction and commissioning, in particular about the design optimization and the validation tests of the lens telescopes. Preliminary values for the incr…
Noise and radiation damage in silicon photomultipliers exposed to electromagnetic and hadronic radiation
2009
For the electron arm tracking system in the KAOS spectrometer at the Mainz Microtron MAMI a detector based on 2 m long scintillating fibres read out by silicon photomultipliers (SiPM) is planned. Because of the detector's close proximity to the intense electron beam a study of noise and radiation damage in SiPM has been performed. A sample of devices was exposed directly to a 14 MeV electron beam and to a mixed radiation field in the experimental area. First noticeable effects are a large increase in the dark count rate and a severe loss of the gain uniformity.
UTSW Small Animal Positron Emission Imager
2006
A Small Animal Imager (SAI) for PET has been designed, built, tested in phantoms, and applied to investigations in mice and rats. The device uses principles based on gamma-ray induced scintillation in crossed fiber optic detectors connected to Position Sensitive Photomultiplier Tubes (PSPMT). Each detector consists of an epoxied stack of 28 layers of 135 round 1 mm BCF-10 scintillating plastic fibers. The overlap region forms a 13.5times13.5times2.8 cm3 detector volume. Scintillating light from the fibers is detected by two (X and Y directions) Hamamatsu R-2486 PSPMTs with 16 anode wires in each of two orthogonal directions. A centroid-finding algorithm gives the position of a light cluster…
Plastic Scintillation Detectors for Time-of-Flight Mass Measurements
2020
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with $^{48}$Ca beam at the NSCL. The new detectors achieved a time resolution ($\sigma$) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the …
Low noise scintillation detectors with a P-47 thin layer screen for electrons of several keV
1994
Abstract The applicability of a low-noise scintillation detector (ScD) for the registration of electrons of several keV energy has been studied employing photomultipliers (PM) of different types and sizes. With the application of a sedimented P-47 scintillation screen, the values of the low-energy sensitivity limit and those of the light conversion coefficient were determined as about 2.7–4.7 keV and 2.8–6.6 photoelectrons/keV, respectively, for the set of PM's (Philips-Valvo XP 2020, Philips-Valvo XP 2052, Philips-Valvo XP 2972, EMI 9124a) studied. It is concluded that such scintillation detectors might be used advantageously as electron counters in the range of E > 5 keV. Applications bel…
Depth of /spl gamma/-ray interaction within continuous crystals from the width of its scintillation light-distribution
2005
We have studied a new and inexpensive method of measuring the depth of interaction (DOI) in /spl gamma/-ray detectors with large-sized scintillation crystals. This method takes advantage of the strong correlation between the width of the undisturbed light-distribution in continuous crystals and the /spl gamma/-ray's DOI. In order to quantify the dependence of the distribution's width with respect to the DOI, we first studied an analytical model of the light-distribution and tested it by means of Monte Carlo (MC) simulations of the light transport inside the crystal. Further we present an inexpensive modification of the commonly used charge division circuit that allows analog and instantaneo…