Search results for "Lies"

showing 10 items of 1093 documents

Comparison of EPR response of alanine and Gd2O3-alanine dosimeters exposed to TRIGA Mainz reactor.

2015

In this work we report some preliminary results regarding the analysis of electron paramagnetic resonance (EPR) response of alanine pellets and alanine pellets added with gadolinium used for dosimetry at the TRIGA research reactor in Mainz, Germany. Two set-ups were evaluated: irradiation inside PMMA phantom and irradiation inside boric acid phantom. We observed that the presence of Gd2O3 inside alanine pellets increases the EPR signal by a factor of 3.45 and 1.24 in case of PMMA and boric acid phantoms, respectively. We can conclude that in the case of neutron beam with a predominant thermal neutron component the addition of gadolinium oxide can significantly improve neutron sensitivity of…

AlanineRadiationAlanineChemistrySettore ING-IND/18 - Fisica Dei Reattori NucleariSettore ING-IND/20 - Misure E Strumentazione NucleariGadoliniumRadiochemistrySettore FIS/01 - Fisica SperimentalePelletschemistry.chemical_elementGadoliniumNeutron radiationequipment and suppliesNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)law.inventionNCT dosimetrylawElectron spin resonanceNeutronTriga reactor MainzIrradiationElectron paramagnetic resonanceNuclear chemistry
researchProduct

Governare il Mezzogiorno. Gli alleati e l'occupazione/liberazione del Sud (1943-1945)

2015

In winter 1943 the United Stated and Britain planned the invasion of Axis-held Europe and decided to invade Sicily. A Military Government (Amgot) – which would be a model for the future Allied administration in Europe – was set in order to administrate the occupied territories. While the Allied propaganda presented the invasion of Italy as a «liberation» from the Axis yoke, when in summer 1943 the Allied troops landed in Sicily, Italy was actually treated as a fully-fledged enemy country. When the Amgot became operative, the contradictory role of the Allies in the occupation emerged clearly. The aim of this article is to examine the complex aspects of this military occupation in Sicily an…

Amgot Mezzogiorno seconda guerra mondiale alleatiSecond World WarAmgotSettore M-STO/04 - Storia ContemporaneaAlliesMezzogiorno
researchProduct

Effect of Temperature on N2O and NO Emission in a Partial Nitrification SBR Treating Reject Wastewater

2017

Temperature is a very important parameter during nitritation, having a direct effect on ammonia oxidation rate (AOR) and enzymatic activities which relate to both N2O and NO emission. This study aims at investigating the effect of temperature on AOR, N2O and NO production in an enriched ammonia oxidizing bacteria (AOB) sequencing batch reactor (SBR) performing partial nitrification (PN) of synthetic reject wastewater. To achieve that, a SBR was subject to several shifts in temperature (in the range of 30 to 15 °C, 5 °C for each decrease). Cycle studies, which contain two aeration phases, were conducted under each temperature. The results showed that AOR specific exponentially correlates wit…

Ammonia oxidation rate Nitrous oxide Nitric oxide Reject wastewater TemperatureSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleInorganic chemistryNitrous OxideReject WastewaterTemperatureSequencing batch reactorAmmonia-oxidizing bacteriaNitrous oxideNitric Oxideequipment and suppliesPulp and paper industryAmmoniachemistry.chemical_compoundAmmonia Oxidation RatechemistryWastewaterNitrificationNo productionAeration
researchProduct

Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.

2007

The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…

AnalyteCorrelation coefficientAnalytical chemistryFresh WaterAlkaliesAnalytical Chemistrylaw.inventionlawOxidizing agentWater Pollution ChemicalHumansPhotodegradationChemiluminescenceBenzofuransDetection limitReproducibilityChromatographyPhotolysisMolecular StructureChemistryHerbicidesVolumetric flow rateFlow Injection AnalysisLuminescent MeasurementsMineral WatersSulfonic AcidsAcidsTalanta
researchProduct

More about sampling and estimation of mercaptans in air samples

2013

[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…

AnalyteSorbentAir samplesAlkaliesHigh-performance liquid chromatographyAnalytical ChemistryCartridgeO-Phthalaldehydechemistry.chemical_compoundMercaptansQUIMICA ANALITICAHumansSulfhydryl CompoundsIsoleucineDerivatizationAir sampling systemFluorescent DyesAir PollutantsChromatographyAirSampling (statistics)DerivatizationSolutionsSpectrometry FluorescencechemistryReagentCalibrationHPLCo-PhthalaldehydeChromatography Liquid
researchProduct

Polyacrylonitrile block copolymers for the preparation of a thin carbon coating around TiO2 nanorods for advanced lithium-ion batteries.

2013

Herein, a new method for the realization of a thin and homogenous carbonaceous particle coating, made by carbonizing RAFT polymerization derived block copolymers anchored on anatase TiO2 nanorods, is presented. These block copolymers consist of a short anchor block (based on dopamine) and a long, easily graphitizable block of polyacrylonitrile. The grafting of such block copolymers to TiO2 nanorods creates a polymer shell, which can be visualized by atomic force microscopy (AFM). Thermal treatment at 700 °C converts the polyacrylonitrile block to partially graphitic structures (as determined by Raman spectroscopy), establishing a thin carbon coating (as determined by transmission electron m…

AnataseMaterials sciencePolymers and PlasticsSurface PropertiesAcrylic Resins02 engineering and technologyThermal treatmentLithium010402 general chemistry01 natural scienceschemistry.chemical_compoundElectric Power SuppliesMaterials ChemistryCopolymerReversible addition−fragmentation chain-transfer polymerizationComposite materialParticle Sizechemistry.chemical_classificationIonsTitaniumNanotubesMolecular StructureOrganic ChemistryPolyacrylonitrileTemperaturePolymerElectrochemical Techniques021001 nanoscience & nanotechnologyCarbon0104 chemical scienceschemistryTransmission electron microscopyNanorod0210 nano-technologyMacromolecular rapid communications
researchProduct

Synthesis and biological evaluation of abietic acid derivatives

2009

A series of C18-oxygenated derivatives of abietic acid were synthesized and evaluated for their cytotoxic, antimycotic, and antiviral activities. In general, the introduction of an aldehyde group at C18 did improve the resultant bioactivity, while the presence of an acid or alcohol led to less active compounds.

Antifungal AgentsCarboxylic acidMolecular ConformationAntineoplastic AgentsAlcoholHerpesvirus 1 HumanMicrobial Sensitivity TestsPrimary alcoholAntiviral AgentsChemical synthesisAldehydeStructure-Activity Relationshipchemistry.chemical_compoundChlorocebus aethiopsDrug DiscoveryAnimalsHumansStructure–activity relationshipOrganic chemistryAbietic acidVero CellsCandidaCell ProliferationPharmacologychemistry.chemical_classificationDose-Response Relationship DrugAspergillus fumigatusOrganic Chemistryfood and beveragesStereoisomerismGeneral Medicineequipment and suppliesAspergilluschemistryDrug DesignAbietaneslipids (amino acids peptides and proteins)DiterpeneHeLa CellsEuropean Journal of Medicinal Chemistry
researchProduct

Candida biofilms on implanted biomaterials: a clinically significant problem.

2006

In recent years there has been an increasing appreciation that microbial biofilms are ubiquitous, which has resulted in a number of studies on infectious diseases from a biofilm perspective. Biofilms are defined as structured microbial communities that are attached to a surface and encased in a matrix of exopolymeric material. A wide range of biomaterials used in clinical practice have been shown to support colonization and biofilm formation by Candida spp., and the increase in Candida infections in the last decades has almost paralleled the increase and widespread use of a broad range of medical implant devices, mainly in populations with impaired host defenses. Formation of Candida biofil…

AntifungalCatheterization Central Venousmedicine.drug_classBiofilmGeneral MedicineProstheses and Implantsbiochemical phenomena metabolism and nutritionBiologyApplied Microbiology and BiotechnologyMicrobiologyCandida infectionsMicrobiologyClinical PracticeImmune systemCatheters IndwellingEquipment and SuppliesRenal DialysisBiofilmsmedicineHumansDenturesMicrobial BiofilmsCandidaFEMS yeast research
researchProduct

Spectroelectrochemistry of cytochrome c and azurin immobilized in nanoporous antimony-doped tin oxide

2011

Stable immobilization of two redox proteins, cytochrome c and azurin, in a thin film of highly mesoporous antimony-doped tin oxide is demonstrated via UV-vis spectroscopic and electrochemical investigation.

AntimonyMaterials scienceInorganic chemistrychemistry.chemical_elementElectrochemistryRedoxCatalysisNanoporesAntimonyAzurinMaterials ChemistrybiologyNanoporousCytochrome ctechnology industry and agricultureMetals and AlloysCytochromes cTin CompoundsElectrochemical TechniquesGeneral Chemistryequipment and suppliesTin oxideSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsImmobilized ProteinschemistryCeramics and Compositesbiology.proteinSpectrophotometry UltravioletAdsorptionAzurinMesoporous materialChemical Communications
researchProduct

Regurgitant flow in apparently normal valve prostheses: improved detection and semiquantitative analysis by transesophageal two-dimensional color-cod…

1990

In 128 patients with apparently normally functioning prosthetic valves ( n = 136) in the aortic position ( n = 79) and the mitral position ( n = 57), the prevalence of transprosthetic regurgitant flow was studied by use of transthoracic and transesophageal two-dimensional color-coded Doppler echocardiography. With the transthoracic approach, regurgitant flow was detected in early systole or diastole for 28% of the mitral prostheses and for 29% of the aortic prostheses. With transesophageal color-coded Doppler echocardiography, regurgitant jets were visualized for 95% of the mitral prostheses and for 44% of the aortic prostheses. In 40% of the Bjork-Shiley prostheses and 88% of the St. Jude …

Aortic valveAdultMalemedicine.medical_specialtyAdolescentAortic Valve InsufficiencyDiastoleDoppler echocardiographyInternal medicineMitral valvemedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesSystoleTransthoracic approachAgedmedicine.diagnostic_testbusiness.industryMiddle Agedequipment and suppliesEchocardiography DopplerRegurgitant flowProsthesis Failuremedicine.anatomical_structureAortic ValveHeart Valve Prosthesiscardiovascular systemCardiologyMitral ValveFemaleCardiology and Cardiovascular MedicinebusinessSemi quantitativecirculatory and respiratory physiologyJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct