Search results for "Linear"

showing 10 items of 7165 documents

Fast evaluation of a linear number of local exchange matrices

2002

A fast method is described for evaluating multiple exchange matrices in a Gaussian atomic orbital basis. For insulators, it is asymptotically linear scaling, and is a generalization of the linear scaling exchange (LinK) method, which was formulated for a single exchange matrix [J. Chem. Phys. 109 (1998) 1663]. It is employed to evaluate exchange-type contractions of all derivative density matrices with two-electron integrals for a series of linear alkanes, linear polyacenes, and water clusters using STO-3G, 3-21G, and 6-31G* basis sets. Significant computational savings are obtained for molecules with as few as 10 non-hydrogen atoms.

Density matrixSeries (mathematics)Basis (linear algebra)ChemistryGaussianGeneral Physics and AstronomyDerivativesymbols.namesakeComputational chemistryLinear scalesymbolsExchange matrixStatistical physicsPhysical and Theoretical ChemistryScalingChemical Physics Letters
researchProduct

Adiabatic Elimination and Sub-space Evolution of Open Quantum Systems

2020

Efficient descriptions of open quantum systems can be obtained by performing an adiabatic elimination of the fast degrees of freedom and formulating effective operators for the slow degrees of freedom in reduced dimensions. Here, we perform the construction of effective operators in frequency space, and using the final value theorem or alternatively the Keldysh theorem, we provide a correction for the trace of the density matrix which takes into account the non trace-preserving character of the evolution. We illustrate our results with two different systems, ones where the eliminated fast subspace is constituted by a continuous set of states and ones with discrete states. Furthermore, we sh…

Density matrixTrace (linear algebra)Atomic Physics (physics.atom-ph)PopulationDegrees of freedom (statistics)FOS: Physical sciences01 natural sciences010305 fluids & plasmasPhysics - Atomic Physics[PHYS.QPHY]Physics [physics]/Quantum Physics [quant-ph]Physics - Chemical Physics0103 physical sciencesMesoscale and Nanoscale Physics (cond-mat.mes-hall)Statistical physics010306 general physicsAdiabatic processeducationComputingMilieux_MISCELLANEOUSPhysicsChemical Physics (physics.chem-ph)education.field_of_studyQuantum PhysicsCondensed Matter - Mesoscale and Nanoscale PhysicsDetailed balanceFinal value theorem[SDU]Sciences of the Universe [physics]Quantum Physics (quant-ph)Subspace topology
researchProduct

A direct Capillary Liquid Chromatography with electrochemical detection method for determination of phenols in water samples

2010

A fast and direct method based on the use of Capillary Liquid Chromatography (LC) with electrochemical (EC) detection has been described for phenols pollutants in water samples. Concretely, phenol, o-cresol, 2-chlorophenol and bisphenol A have been selected as target analytes. The combination of Capillary LC with EC detection avoided the necessity of preconcentration steps typically used in environmental analysis. The sample injected volume was 2 μL. The achieved detection limits were between 1 and 2 μg/L and the linear dynamic range was up to 50 μg/L for all studied phenols. The precision and uncertainty were satisfactory. The analysis time per sample was 10 min. The proposed procedure has…

Detection limitAnalyteChromatographyEnvironmental analysisCapillary actionOrganic ChemistryAnalytical chemistryReproducibility of ResultsFresh WaterGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundPhenolschemistryCapillary ElectrochromatographyLinear ModelsPhenolSeawaterPhenolsQuantitative analysis (chemistry)Water Pollutants ChemicalJournal of Chromatography A
researchProduct

SiPM as miniaturised optical biosensor for DNA-microarray applications

2015

A miniaturized optical biosensor for low-level fluorescence emitted by DNA strands labelled with CY5 is showed. Aim of this work is to demonstrate that a Si-based photodetector, having a low noise and a high sensitivity, can replace traditional detection systems in DNA-microarray applications. The photodetector used is a photomultiplier (SiPM), with 25 pixels. It exhibits a higher sensitivity than commercial optical readers and we experimentally found a detection limit for spotted dried samples of ∼1 nM. We measured the fluorescence signal in different operating conditions (angle of analysis, fluorophores concentrations, solution volumes and support). Once fixed the angle of analysis, for s…

Detection limitAnalytePhotomultiplierMaterials scienceoptical biosensorbusiness.industrySiPMDNA microarrayPhotodetectorLinearityDNA-microarraySignalSettore ING-INF/01 - ElettronicaElectronic Optical and Magnetic MaterialsSilicon photomultiplierOpticslcsh:TA1-2040DNA microarray; Fluorophore detection; Optical Biosensor; SiPMSignal ProcessingElectrical and Electronic Engineeringbusinesslcsh:Engineering (General). Civil engineering (General)Sensitivity (electronics)Fluorophore detectionBiotechnologySensing and Bio-Sensing Research
researchProduct

Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests

2009

Mika PA Laitinen1, Jari Salmela2, Leona Gilbert1, Risto Kaivola1, Topi Tikkala2, Christian Oker-Blom1, Jukka Pekola3, Matti Vuento11Department of Biological and Environmental Science; 2Department of Physics, University of Jyväskylä, Jyväskylä, Finland; 3Low Temperature Laboratory, Helsinki University of Technology, Helsinki, FinlandAbstract: A rapid method and instrumentation for quantification of immunochromatographic tests (ICT) are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG) present in urine. The test format was a sandwich assay using two distinct monoclonal antib…

Detection limitAnalyteendocrine systemChromatographyChemistryCapillary actionmedicine.drug_classBiomedical EngineeringBioengineeringBioinformaticsMonoclonal antibodyLinear rangemedicineUrine sampleBiosensorhormones hormone substitutes and hormone antagonistsSuperparamagnetismOriginal ResearchNanotechnology Science and ApplicationsNanotechnology, Science and Applications
researchProduct

The natural compound chrysosplenol-D is a novel, ultrasensitive optical sensor for detection of Cu(II)

2020

Abstract Herein, we introduce a novel, ultrasensitive optical sensor for determination of Cu(II) ions over the concentration range of 0 to 1 μM Cu(II). The optical sensor is based on the natural molecule chrysosplenol-D (Chp-D) extracted from the flowering plant Chiliadenus montanus (Vahl.) Brullo. Free Chp-D emits fluorescence at 566 nm when excited at 292 nm. Chp-D chelates Cu(II) ions to form a 1:1 (metal:ligand) complex, which quenches the fluorescence emission peak of the free probe at 566 nm. “Turn-off” luminescence could be easily determined and provided distinct proof of the chelation of Cu(II) ions by Chp-D. This novel optical sensor offers a considerable fluorescence mechanism (ch…

Detection limitChemistryAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyCondensed Matter PhysicsCharge-transfer complex01 natural sciencesFluorescenceBinding constantAtomic and Molecular Physics and Optics0104 chemical sciencesElectronic Optical and Magnetic Materialssymbols.namesakeLinear rangeStokes shiftMaterials ChemistrysymbolsMoleculePhysical and Theoretical Chemistry0210 nano-technologyLuminescenceSpectroscopyJournal of Molecular Liquids
researchProduct

High-performance liquid chromatographic determination of tocopherols in infant formulas

2002

A method for the simultaneous determination of alpha-tocopherol acetate and alpha-, delta-, and gamma-tocopherols by normal-phase high-performance liquid chromatography (HPLC) with a fluorescent detector in infant formula is proposed. The values obtained in the determination of the analytical parameters: linearity, precision, limit of detection and accuracy (analysis of a standard reference material, SRM 1846), confirm the quality of the method. The proposed method is useful for the determination of alpha-, delta-, and gamma-tocopherols and alpha-tocopherol acetate in infant formulas at a low cost and in a total time of 2 h.

Detection limitChromatographyChemistryVitamine eOrganic ChemistryDetectorAnalytical chemistryInfantReproducibility of ResultsTocopherolsfood and beveragesLinearityGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySpectrometry FluorescenceHumansInfant FoodQuantitative analysis (chemistry)Chromatography High Pressure LiquidAnalysis methodJournal of Chromatography A
researchProduct

Fourier transform infrared determination of Fluometuron in pesticide formulations

2003

Abstract A single method has been developed for Fourier transform infrared (FTIR) determination of Fluometuron in pesticide formulations. Samples were ultrasonically shaken with CHCl3 for 5 min and the FTIR spectra of sample extracts and standards were obtained at a nominal resolution of 4 cm−1 from 4000 to 900 cm−1 accumulating 25 scans. Fluometuron determination is based on the measure of peak area from 1342 to 1321 cm−1 corrected using a baseline defined from 1352 to 1294 cm−1. This procedure provided a limit of detection of 6.5 μg g−1, a sensitivity of 0.852 a.u. g mg−1 for a pathlength of 0.11 mm, a relative standard deviation of 1.6% for three analysis of a sample containing 50.4% (w/…

Detection limitChromatographyChloroformFluometuronResolution (mass spectrometry)Analytical chemistryHigh-performance liquid chromatographychemistry.chemical_compoundsymbols.namesakeFourier transformchemistryLinear regressionsymbolsFourier transform infrared spectroscopySpectroscopyVibrational Spectroscopy
researchProduct

Electrochemical detection of uric acid and ascorbic acid using r-GO/NPs based sensors

2021

Abstract A sensitive and selective electrochemical sensor, based on reduced graphene oxide and gold nanoparticles obtained by simple co-electrodeposition, was developed for the detection of uric acid and ascorbic acid. Because of the electrochemical oxidation of both uric and ascorbic acid depending on the pH, the sensor performances were studied at different pH values. Excellent results were obtained for uric acid detection in a linear range from 10 to 500 µmol dm−3 with a sensitivity of 0.31 µA cm−2 µM−1. A limit of detection and quantification of 3.6 µM and 10.95 µmol dm−3, respectively, was calculated. Sensors showed good selectivity toward different interfering species present in the m…

Detection limitChromatographyGeneral Chemical Engineering02 engineering and technologyUrineUric acid Food010402 general chemistry021001 nanoscience & nanotechnologyAscorbic acid01 natural sciences0104 chemical sciencesElectrochemical gas sensorMatrix (chemical analysis)chemistry.chemical_compoundBody fluidsSettore ING-IND/23 - Chimica Fisica ApplicatachemistryLinear rangeElectrochemical sensorColloidal goldSettore ING-IND/17 - Impianti Industriali MeccaniciElectrochemistryUric acidAscorbic acid0210 nano-technology
researchProduct

Identification of Leguminosae gums and evaluation of carob-guar mixtures by capillary zone electrophoresis of protein extracts.

2002

A procedure for the extraction and capillary zone electrophoresis (CZE) separation of proteins from carob, guar and tara gums in a background electrolyte (BGE) of pH 9 containing 0.1% polyvinyl alcohol is described. The CZE protein profiles exhibit characteristic peaks for each one of the Leguminosae gums, which can be used to construct models capable of identifying samples of carob, guar and tara gums, and predicting the guar content in binary carob-guar mixtures of different geographical origin and harvested in different years. The classification and prediction models are constructed by using linear discriminant analysis (LDA) and multiple linear regression (MLR), respectively. An excelle…

Detection limitChromatographyGuar gumResolution (mass spectrometry)ChemistryPlant ExtractsClinical BiochemistryExtraction (chemistry)GuarElectrophoresis CapillaryFabaceaeBiochemistryGalactansAnalytical ChemistryMannansCapillary electrophoresisModels ChemicalPolysaccharidesLinear regressionCalibrationPlant GumsElectrophoresis
researchProduct