Search results for "Liquid Chromatography"

showing 10 items of 942 documents

A comparison of various calibration techniques applied to the ninhydrin-cefoxitin determination

1996

Abstract This report deals with spectrophotometric determination of cefoxitin from intact antibiotics or from its acid induced degradation product by means of their reaction with ninhydrin in a strong sulphuric acid medium. To obtain the calibration graphs four methods were used: absorbance of reacted cefoxitin against a reagent blank as an analytical signal, first-derivative signal of absorbance against a water blank as an analytical signal, first-derivative signal of absorbance against a reagent blank as an analytical signal and the H-Point Standard Additions Method (HPSAM) by using absorbance increment values as analytical signals. The HPSAM is applied to the determination of cefoxitin i…

Chromatographymedicine.diagnostic_testChemistrydigestive oral and skin physiologyBiochemistryBlankHigh-performance liquid chromatographyAnalytical ChemistryAbsorbancechemistry.chemical_compoundSpectrophotometryNinhydrinReagentStandard additionmedicineEnvironmental ChemistryCefoxitinSpectroscopymedicine.drugAnalytica Chimica Acta
researchProduct

Comparison of spectrophotometric and HPLC methods for determining sialic acid in infant formulas

2011

Abstract Two methods for determining sialic acid in infant formulas – spectrophotometry and HPLC with fluorescence detection – have been optimised and validated, the first one allows to determine total sialic acid while the second allows to differentiate the two main forms of sialic acid (N-acetylneuraminic acid (Neu5Ac) and N-glycolylneuraminic acid (Neu5Gc)). A common sample preparation procedure (hydrolysis and purification) for both methods has been proposed. The linearity (from 6 to 150 μg of total sialic acid in the assay for spectrophotometry, and from 12.5 to 250 ng and 1 to 5 ng of Neu5Ac and Neu5Gc, respectively, for HPLC) is adequate. The detection and quantification limits (0.29…

Chromatographymedicine.diagnostic_testRelative standard deviationGeneral MedicineHigh-performance liquid chromatographyFluorescenceAnalytical ChemistrySialic acidHydrolysischemistry.chemical_compoundInfant formulachemistrySpectrophotometrymedicineSample preparationFood ScienceFood Chemistry
researchProduct

Rapid and simultaneous high-performance liquid chromatography assay of polyamines and monoacetylpolyamines in biological specimens

2000

A rapid, resolutive and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for polyamines and acetylpolyamines by adopting pre-column derivatization with benzoyl chloride. In a single run lasting less than 15 min ten polyamines were separated as well as traces of benzoic acid, methylbenzoate and benzoic anhydride. These contaminants, produced during the derivatization reaction, were almost all eliminated by washing steps envisaged in the same procedure. This simple and sensitive method can be applied to routine determination of polyamines in biological samples. A fine application of this procedure to the determination of endogenous content of p…

Chromatographymedicine.diagnostic_testorganic chemicalsBiogenic PolyaminesReproducibility of ResultsGeneral ChemistryReversed-phase chromatographyReference StandardsSensitivity and SpecificityHigh-performance liquid chromatographyBenzoic anhydridechemistry.chemical_compoundBenzoyl chloridechemistrySpectrophotometrymedicineSpectrophotometry UltravioletDerivatizationQuantitative analysis (chemistry)Chromatography High Pressure LiquidBenzoic acidJournal of Chromatography B: Biomedical Sciences and Applications
researchProduct

Separation of the enantiomers of primary and secondary amphetamines by liquid chromatography after derivatization with (−)-1-(9-fluorenyl)ethyl chlor…

2003

The chiral reagent (−)-1-(9-fluorenyl)ethyl chloroformate (FLEC) has been evaluated for the enantioselective analysis of amphetamines by liquid chromatography. For separation of the FLEC diastereomers conventional reversed-phase conditions were used. The conditions affording the best enantiomeric resolution and sensitivity were determined for amphetamine, methamphetamine, ephedrine, pseudoephedrine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDE). All the amphetamines assayed could be separated with resolution factors ranging from 0.91 to 1.92. Although FLEC is typically used as a fluorogenic reagent, it was shown t…

Chromatographymedicine.drug_classOrganic ChemistryClinical BiochemistryReversed-phase chromatographyPseudoephedrineBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryDesigner drugchemistry.chemical_compoundchemistrymedicineEthyl chloroformateEnantiomerEphedrineDerivatizationmedicine.drugChromatographia
researchProduct

Biopartitioning micellar chromatography to pedict mutagenicity of aromatic amines

2007

[EN] Mutagenicity is a toxicity endpoint associated with the chronic exposure to chemicals. Aromatic amines have considerable industrial and environmental importance due to their widespread use in industry and their mutagenic capacity. Biopartitioning micellar chromatography (BMC), a mode of micellar liquid chromatography that uses micellar mobile phases of Brij35 in adequate experimental conditions, has demonstrated to be useful in mimicking the drug partitioning process into biological systems. In this paper, the usefulness of BMC for predicting mutagenicity of aromatic amines is demonstrated. A multiple linear regression (MLR) model based on BMC retention data is proposed and compared wi…

Chronic exposureQuantitative structure–activity relationshipPredictive capabilityQuantitative Structure-Activity RelationshipAromatic aminesHigh-performance liquid chromatographyModels BiologicalMutagenicityDrug DiscoveryQUIMICA ANALITICAOrganic chemistryComputer SimulationAminesLeast-Squares AnalysisMicellesPharmacologychemistry.chemical_classificationChromatographyChromatographyOrganic ChemistryAromatic amineGeneral MedicineBiopartitioning micellar chromatographychemistryMicellar liquid chromatographyMutagenesisQuantitative retentione-activity relationships
researchProduct

Extraction of polycyclic aromatic hydrocarbons from cookies: a comparative study of ultrasound and microwave-assisted procedures.

2008

The chromatographic determination of 15 polycyclic aromatic hydrocarbons (PAHs) in cookies has been improved in order to obtain a fast method with a low limit of detection through the combination of microwave-assisted extraction (MAE), oil saponification and solid-phase extraction clean-up before the injection of purified extracts in a C18 201TP52 (5 microm, 250 x 2.1 mm) column. Using acetonitrile-water as mobile phase, with a 50% to 95% w/w acetonitrile gradient for a fixed flow of 0.250 ml min(-1), 15 PAHs were separated in 45 min. The column temperature was maintained at 15 degrees C; and fluorimetric detection was made at a fixed excitation wavelength of 264 nm and emission measurement…

ChryseneHealth Toxicology and MutagenesisFlourAnalytical chemistryFood ContaminationFluoreneToxicologyHigh-performance liquid chromatographychemistry.chemical_compoundFood IndustryFluorometryUltrasonicsSolid phase extractionPolycyclic Aromatic HydrocarbonsMicrowavesChromatography High Pressure LiquidDetection limitChromatographyExtraction (chemistry)Solid Phase ExtractionPublic Health Environmental and Occupational HealthGeneral ChemistryGeneral MedicineToluenechemistryPyreneFood ScienceFood additivescontaminants. Part A, Chemistry, analysis, control, exposurerisk assessment
researchProduct

Direct optical resolution of trans-dihydrodiol enantiomers of fjord-region polycyclic aromatic hydrocarbons by high-performance liquid chromatography…

1998

Abstract Enantioselective separation of trans -dihydrodiol metabolites of a series of fjord-region polycyclic aromatic hydrocarbons (PAHs), such as benzo[ c ]phenanthrene and dibenzo[ a , l ]pyrene, was evaluated by HPLC using commercially available cellulose-based CSPs as chiral columns. A baseline separation ( R s ≥1.6) with sharp, well-defined peaks of individual enantiomers was attained using cellulose-tris-( N -3,5-dimethylphenylcarbamate) and n -heptane-ethanol (9:1, v/v) as mobile phase. These chromatographic conditions permit a direct, simple and rapid (mostly within 30 min) enantiomeric resolution of PAH dihydrodiols. CD spectra were obtained for all optically pure enantiomers and …

Circular dichroismChromatographyResolution (mass spectrometry)Organic ChemistryEnantioselective synthesisAbsolute configurationGeneral MedicinePhenanthreneBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistryPyreneEnantiomerJournal of Chromatography A
researchProduct

HPLC study on the ‘history’ dependence of gramicidin A conformation in phospholipid model membranes

1989

AbstractA novel HPLC methodology for the study of gramicidin A reconstituted in model membranes has been tested in comparison with circular dichroism data. It is shown that this chromatographic technique not only corroborates most of the recent spectroscopic results but allows one to explain them in terms of mass fractions of different actual conformational species of GA in the phospholipid assemblies. In particular, the dependence of the inserted peptide configuration on the organic solvent and other parameters involved in the ‘history’ of the sample preparation and handling has been analyzed by HPLC in two phospholipid model systems: small unilamellar vesicles and micelles. Moreover, a sl…

Circular dichroismProtein ConformationMolecular ConformationBiophysicsPhospholipidPeptideBiochemistryHigh-performance liquid chromatographyMicellechemistry.chemical_compoundStructural BiologyGramicidin A conformationGeneticsGramicidin ASample preparationMolecular BiologyChromatography High Pressure Liquidchemistry.chemical_classificationChromatographyChemistryCircular DichroismGramicidinMembranes ArtificialCell BiologyModels TheoreticalCDMembraneLiposomesPhospholipid vesiclePhosphatidylcholinesHPLCFEBS Letters
researchProduct

Liquid chromatographic–mass spectrometric determination of post-harvest fungicides in citrus fruits

2001

Liquid chromatography (LC)-atmospheric pressure ionisation (API)-mass spectrometry (MS) has been used to determine residues of five fungicides in oranges with a minimum sample cleanup. Atmospheric pressure chemical ionisation (APCI) and electrospray (ES) were compared and both gave similar results in terms of sensitivity and structural information. The main ions were [M+H]+ for carbendazim, imazalil, thiophanate methyl and thiabendazole, and [M+H-C4H9NHCO]+ for benomyl. Samples were extracted with sodium sulphate and ethyl acetate. Although benomyl and thiophanate methyl were transformed through the extraction procedure to carbendazim, the method showed good precision (13%) and recovery (70…

CitrusSpectrometry Mass Electrospray IonizationChemical ionizationElectrosprayChromatographyCarbendazimOrganic ChemistryEthyl acetateReproducibility of ResultsBenomylAtmospheric-pressure chemical ionizationGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyFungicides IndustrialAnalytical ChemistryFungicidechemistry.chemical_compoundAtmospheric PressurechemistryChromatography LiquidJournal of Chromatography A
researchProduct

Strategies to In Vitro Assessment of Major Human CYP Enzyme Activities by Using Liquid Chromatography Tandem Mass Spectrometry

2008

At the early stage of drug discovery, thousands of new chemical entities (NCEs) may be screened before a single candidate can be identified for development. Determining the role of CYP enzymes in the metabolism of a compound and evaluating the effect of NCEs on human CYP activities are key issues in pharmaceutical development as they may explain inter-subject variability, drug-drug interactions, non-linear pharmacokinetics and toxic effects. Reliable methods for determining enzyme activities are needed to characterize an individual CYP enzyme and to obtain a tool for the evaluation of its role in drug metabolism in humans. Different liquid chromatography tandem mass spectrometry methodologi…

Clinical BiochemistryDrug Evaluation PreclinicalIn Vitro TechniquesTandem mass spectrometrySubstrate SpecificityCytochrome P-450 Enzyme SystemPharmacokineticsTandem Mass SpectrometryIn vivoLiquid chromatography–mass spectrometryCytochrome P-450 Enzyme InhibitorsHumansPharmacokineticsEnzyme inducerChromatography High Pressure LiquidCytochrome P-450 Enzyme InhibitorsPharmacologyChromatographybiologyDrug discoveryChemistryPharmaceutical PreparationsBiochemistryEnzyme InductionHepatocytesMicrosomes Liverbiology.proteinDrug metabolismCurrent Drug Metabolism
researchProduct