Search results for "Liquid Chromatography"

showing 10 items of 942 documents

Longitudinal analysis of taurine induced effects on the tear proteome of contact lens wearers and dry eye patients using a RP-RP-Capillary-HPLC-MALDI…

2012

Tear proteomic studies revealed distinct similarities between contact lens wearers and dry eye patients. AMO Complete® multipurpose contact lens cleaning solutions containing taurine seem to have a beneficial effect regarding contact lens induced dry eye. To illuminate the effect of taurine on the tear proteome of contact lens wearers and sicca patients we developed a gel-based RP-RP capillary HPLC-MALDI TOF/TOF MS strategy. Two contact lens wearer groups, one using eye drops containing 0.05% taurine; the other for control physiological NaCl solution were monitored. Also, a third group of sicca patients using taurine solution was studied (N=4 individuals/group). Tear pools of each group at …

AdultMaleTaurinemedicine.medical_specialtyTime FactorsProteomeCapillary actionContact LensesTaurineBiophysicsAnalytical chemistryBiologyBiochemistryHigh-performance liquid chromatographychemistry.chemical_compoundOphthalmologymedicineHumansLongitudinal StudiesChromatography High Pressure Liquideye diseasesContact lensMatrix-assisted laser desorption/ionizationmedicine.anatomical_structurechemistryLens (anatomy)Spectrometry Mass Matrix-Assisted Laser Desorption-IonizationTearsProteomeTearsDry Eye SyndromesFemaleContact Lens SolutionsJournal of proteomics
researchProduct

Automated Determination of Ziprasidone by HPLC With Column Switching and Spectrophotometric Detection

2005

An isocratic high-performance liquid chromatography (HPLC) method with column switching and ultraviolet (UV) detection is described for quantitative analysis of the new antipsychotic drug ziprasidone. After centrifugation of serum or plasma samples and addition of fluperlapine as internal standard, the samples were injected into the HPLC system. On-line sample clean-up was conducted on a column (10 x 4.0 mm ID) filled with silica C8 material (20-microm particle size) using 8% (vol/vol) acetonitrile in deionized water as eluent. Ziprasidone was eluted and separated on ODS Hypersil C18 material (5 microm; column size 250 x 4.6 mm ID) using acetonitrile-water-tetramethylethylendiamine (50:49.6…

AdultMaleTime FactorsSensitivity and SpecificityHigh-performance liquid chromatographyDrug Administration SchedulePiperazinesAutomationBenzodiazepinesBlood serumColumn chromatographymedicineHumansPharmacology (medical)ZiprasidoneClozapineChromatography High Pressure LiquidPharmacologyDetection limitChromatographymedicine.diagnostic_testElutionChemistryReproducibility of ResultsMiddle AgedThiazolesOlanzapineSpectrophotometryTherapeutic drug monitoringSchizophreniaFemaleDrug MonitoringQuantitative analysis (chemistry)medicine.drugTherapeutic Drug Monitoring
researchProduct

Evaluation of the plasmatic level of mepivacaine in different anatomical regions

2018

Background To evaluate the serum level of the local anesthetic mepivacaine 3% without vasoconstrictor in patients who underwent procedures performed in the anterior and posterior maxilla, through a method of possible extraction to quantify it in human plasma by high performance liquid chromatography (HPLC). Material and Methods This was a hybrid study consisting of 18 patients (7 females and 11 males) classified as ASA I, adults and with normal body mass index, submitted to procedures in the anterior region (group I) and posterior region of the maxilla (group II). For 40 minutes, five 6 ml blood samples were collected every 10 minutes after infiltrative injection in each region of the maxil…

AdultMalemedicine.drug_classGroup iiMepivacaineBlood PressureHigh-performance liquid chromatographyHeart RateHeart rateMaxillaHumansMedicineAnesthetics LocalGeneral DentistryAgedAged 80 and overbusiness.industryLocal anestheticResearchSignificant differenceMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Blood pressureOtorhinolaryngologyMaxillaAnesthesiaMepivacaineUNESCO::CIENCIAS MÉDICASFemaleSurgeryOral Surgerybusinessmedicine.drug
researchProduct

Comparison of131I-metaiodobenzylguanidine scintigraphy with urinary and plasma catecholamine determinations in the diagnosis of pheochromocytoma

1985

In a retrospective study of 31 patients with suspected pheochromocytoma we examined the preoperative results of 131I-metaiodobenzylguanidine (131-I-MIBG) scintigraphy and a fluorimetric urine catecholamine determination test. An additional radioenzymatic plasma catecholamine determination test was performed in 25 patients. In 14 of the 31 patients the diagnosis of pheochromocytoma was later histologically confirmed. In the remaining 17 patients the suspected diagnosis was finally rejected after a clinical decision had been made on the basis of clinical history, symptoms, laboratory and imaging tests. 131-I-MIBG scintigraphy apparently had a very high specificity (no false-positive results a…

AdultMalemedicine.medical_specialtyPathologyUrinary systemAdrenal Gland NeoplasmsUrologyPheochromocytomaUrineScintigraphyHigh-performance liquid chromatographyPheochromocytomaCatecholaminesPathognomonicDrug DiscoverymedicineHumansRadionuclide ImagingGenetics (clinical)AgedRetrospective Studiesmedicine.diagnostic_testIodobenzenesbusiness.industryRetrospective cohort studyGeneral MedicineMiddle Agedmedicine.disease3-IodobenzylguanidineCatecholamineMolecular MedicineFemalebusinessmedicine.drugKlinische Wochenschrift
researchProduct

Enriched cereal bars are more effective in increasing plasma quercetin compared with quercetin from powder-filled hard capsules

2011

The flavonol quercetin, is one of the major flavonoids found in edible plants. The bioavailability of quercetin in humans may be influenced by the food matrix in which it is consumed as well as by its chemical and physical form. The objective of the present study was to investigate the biokinetics of quercetin from quercetin-enriched cereal bars and quercetin powder-filled hard capsules. In a randomised, single-blinded, diet-controlled cross-over study, six healthy women aged 22–28 years took a single oral dose of approximately 130 mg quercetin equivalents from either quercetin-enriched cereal bars (containing 93·3 % quercetin aglycone plus 6·7 % quercetin-4′-glucoside) or quercetin powder-…

AdultMedicine (miscellaneous)CapsulesPilot ProjectsDisaccharidesHigh-performance liquid chromatographyAntioxidantsSingle oral doseYoung Adultchemistry.chemical_compoundHumansIngestionSingle-Blind MethodFood scienceAntihypertensive AgentsIsorhamnetinCross-Over StudiesNutrition and DieteticsBioavailabilityKineticsTamarixetinAglyconechemistryBiochemistryDietary SupplementsFood FortifiedFast FoodsFemaleQuercetinPowdersEdible GrainQuercetinNutritive ValueBritish Journal of Nutrition
researchProduct

Comparison of high-pressure liquid chromatography (HPLC) and Griess reagent-spectroscopic methods for the measurement of nitrate in serum from health…

2008

Bioavailability of NO can be estimated by measuring the concentration of nitrate (NO(3)) in serum. However, the methods used for the measurement NO(3) in plasma or serum show a great degree of variation. Therefore, we compared two analytical methods for the measurement of NO(3) in serum.The concentration of NO(3) in 600 serum samples collected from healthy individuals was determined by the HPLC and by the Griess reagent-spectroscopic method.The concentration of NO(3) in the samples was 29.4+/-16.1 micromol/L and 26.2+/-14.0 micromol/L (mean+/-SD) measured by HPLC and Griess reagent-spectroscopic method respectively (p0.0001). We detected a significant correlation between the two methods (R=…

Adultinorganic chemicalsAdolescentClinical BiochemistryHigh-performance liquid chromatographyYoung Adultchemistry.chemical_compoundNitrateGriess testSulfanilamidesHumansHplc methodReference standardsChromatography High Pressure LiquidAgedAged 80 and overNitratesChromatographySpectrum Analysisorganic chemicalsfood and beveragesGeneral MedicineMiddle AgedReference StandardsEthylenediaminesSerum samplesBioavailabilitychemistryHealthy individualsClinical Biochemistry
researchProduct

Comparison of UV and charged aerosol detection approach in pharmaceutical analysis of statins

2009

Abstract CAD (charged aerosol detector) has recently become a new alternative detection system in HPLC. This detection approach was applied in a new HPLC method for the determination of three of the major statins used in clinical treatment—simvastatin, lovastatin and atorvastatin. The method was optimized and the influence of individual parameters on CAD response and sensitivity was carefully studied. Chromatography was performed on a Zorbax Eclipse XDB C18 (4.6 mm × 75 mm, 3.5 μm), using acetonitrile and formic acid 0.1% as mobile phase. The detection was performed using both CAD (20 pA range) and DAD (diode array detector—238 nm) simultaneously connected in series. In terms of linearity, …

AerosolsSimvastatinAccuracy and precisionChromatographyChemistryFormic acidDetectorAnalytical chemistryLinearityCADHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundEquipment and SuppliesHeptanoic AcidsWide dynamic rangeAtorvastatinPyrrolesLovastatinHydroxymethylglutaryl-CoA Reductase InhibitorsQuantitative analysis (chemistry)Chromatography High Pressure LiquidTabletsTalanta
researchProduct

Characterization of oligomeric compounds in secondary organic aerosol using liquid chromatography coupled to electrospray ionization Fourier transfor…

2009

The components of secondary organic aerosols (SOAs) generated from the gas-phase ozonolysis of two C(10)H(16)-terpenes (alpha-pinene; sabinene) and a cyclic C(6)H(10) alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed-phase high-performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well-known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental …

AerosolsSpectrometry Mass Electrospray IonizationChromatographyChemistryElectrospray ionizationOrganic ChemistryAnalytical chemistryExtractive electrospray ionizationMass spectrometryTandem mass spectrometryFourier transform ion cyclotron resonanceIon sourceAnalytical ChemistryTandem Mass SpectrometryCyclohexenesSpectroscopy Fourier Transform InfraredMonoterpenesDirect electron ionization liquid chromatography–mass spectrometry interfaceChromatography High Pressure LiquidSpectroscopyBicyclic MonoterpenesAmbient ionizationRapid Communications in Mass Spectrometry
researchProduct

Determination of aflatoxins in peanuts by matrix solid-phase dispersion and liquid chromatography

2003

A new method based on matrix solid-phase dispersion (MSPD) extraction was studied to determine aflatoxin B1, B2, G1 and G2 from peanuts. Optimization of different parameters, such as type of solid supports for matrix dispersion and elution solvents were carried out. The method used 2 g of peanut sample, 2 g of C18 bonded silica as MSPD sorbent and acetonitrile as eluting solvent. Recoveries of each aflatoxin spiked to peanut samples at 2.5 ng/g (5 ng/g for aflatoxin G2) level were between 78 and 86% with relative standard deviations ranging from 4 to 7%. The limits of quantification ranged from 0.125 to 2.5 ng/g for the four studied aflatoxins using liquid chromatography (LC) with fluoresce…

AflatoxinElectrosprayChromatographyArachisElutionChemistryOrganic ChemistryExtraction (chemistry)Enzyme-Linked Immunosorbent AssayGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)Spectrometry FluorescenceAflatoxinsSample preparationSolid phase extractionChromatography LiquidJournal of Chromatography A
researchProduct

High Pressure Processing Impact on Alternariol and Aflatoxins of Grape Juice and Fruit Juice-Milk Based Beverages.

2021

High-pressure processing (HPP) has emerged over the last 2 decades as a good alternative to traditional thermal treatment for food safety and shelf-life extension, supplying foods with similar characteristics to those of fresh products. Currently, HPP has also been proposed as a useful tool to reduce food contaminants, such as pesticides and mycotoxins. The aim of the present study is to explore the effect of HPP technology at 600 MPa during 5 min at room temperature on alternariol (AOH) and aflatoxin B1 (AFB1) mycotoxins reduction in different juice models. The effect of HPP has also been compared with a thermal treatment performed at 90 °C during 21 s. For this, different juice models, or…

AflatoxinFood industryFood HandlingLiquid Phase MicroextractionAlternariolPharmaceutical ScienceOrganic chemistryFood Contamination01 natural sciencesArticlealternariolAnalytical ChemistryPascalizationBeverageschemistry.chemical_compoundLactones0404 agricultural biotechnologyQD241-441AflatoxinsTandem Mass Spectrometryjuice modelsDrug Discoverydispersive liquid–liquid microextractionAnimalsVitisFood sciencePhysical and Theoretical ChemistryMycotoxinChromatography High Pressure LiquidOrange juicehigh-pressure processingbusiness.industry010401 analytical chemistry04 agricultural and veterinary sciencesMycotoxinsFood safety040401 food science0104 chemical sciencesFruit and Vegetable JuicesMilkchemistryChemistry (miscellaneous)Fruitaflatoxin B1Molecular Medicinebusinessliquid chromatography coupled to tandem mass spectrometryFood contaminantMolecules (Basel, Switzerland)
researchProduct