Search results for "Low frequency"

showing 10 items of 97 documents

Attenuation of low frequency magnetic fields produced by HV underground power cables

2015

High-voltage underground cable systems are becoming more common as the demand for electrical power within urban centers increase, also considering the difficulties in building new overhead power lines in the vicinity of city centers because of authorization issues. Therefore, interest towards the evaluation of magnetic fields produced by high-voltage power lines has been triggered during the last decade and concern about effects on human health of exposure to extra low frequency (ELF) magnetic fields due to power lines has been increasing as well. Hence, the evaluation of the magnetic field produced by underground power cables is important in order to develop methods for mitigating their in…

EngineeringMitigationbusiness.industryOverhead (engineering)Electrical engineeringLine (electrical engineering)Magnetic fieldPower (physics)Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-IND/31 - ElettrotecnicaElectric power transmissionMagnetic FieldShieldingExtremely low frequencyElectric powerbusinessElectrical conductorUnderground Power Transmission Lines
researchProduct

Experimental investigation of the kink effect and the low frequency noise properties in pseudomorphic HEMT’s

2005

The kink effect in low-noise pseudomorphic (AlGaAs/InGaAs) HEMT's has been examined in detail by investigating the steady-state and pulsed I-V characteristics, the behavior of the output conductance dispersion and the performance of the gate leakage current to understand its origin. No clear evidence of impact ionization occurrence in the InGaAs channel at kink bias conditions (V-DS.kink = 1.5 V) has been found, thus suggesting that the predominant mechanism should be attributed to trap-related phenomena. A significant rise of the gate current has been found at very high drain voltages (far from V-DS.kink) associated with low drain current values which is probably due to impact ionization o…

IMPACT IONIZATIONCondensed matter physicsChemistrybusiness.industryInfrasoundGATEElectrical engineeringConductanceHigh-electron-mobility transistorLow frequencyCondensed Matter::Mesoscopic Systems and Quantum Hall EffectCondensed Matter PhysicsCutoff frequencyElectronic Optical and Magnetic MaterialsImpact ionizationDispersion (optics)Materials ChemistryINALAS/INGAAS HEMTSElectrical and Electronic EngineeringbusinessDRAINLIGHT-EMISSIONBEHAVIORNoise (radio)Solid-State Electronics
researchProduct

Refractive index of the CuAlO2delafossite

2008

The refractive index of the CuAlO2 delafossite has been determined from interference measurements in single crystals performed in the visible, near and mid infrared regions of the spectrum. The analysis of the refractive index dispersion corresponding to light polarization perpendicular to the c-axis (P ⊥ c) yields a static dielectric constant of 0 = 7.7 ± 0.8 and a low frequency electronic constant ∞ = 5.1 ± 0.1. The relevant infrared active mode is found to be at 550 ± 25 cm−1. The electronic contribution can be well described by a Penn gap at 39 000 ± 1000 cm−1. Both the refractive index and its dispersion are found to be smaller for P||c than for P ⊥ c.

InfraredChemistrybusiness.industryAnalytical chemistryLow frequencyengineering.materialCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsDelafossiteOpticsDispersion (optics)Materials ChemistryPerpendicularengineeringElectrical and Electronic EngineeringRefractive index dispersionConstant (mathematics)businessRefractive indexSemiconductor Science and Technology
researchProduct

Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque …

2017

International audience; Objective To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency.Design A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dyna…

Knee JointmuscleElectric Stimulation TherapyPhysical Therapy Sports Therapy and RehabilitationStimulationIsometric exerciseLow frequencyKnee extensionCurrent Efficiencylaw.inventionhealthy womenPhysical MedicineYoung Adult03 medical and health sciences0302 clinical medicinelawIsometric Contraction[ SDV.MHEP ] Life Sciences [q-bio]/Human health and pathologyHumansMedicineTorquecurrent amplitudeElectrotherapyquadriceps femoriscurrentsbusiness.industryPulse (signal processing)RehabilitationPulse duration030229 sport sciencesEvoked Potentials Motorwave-formsHealthy Volunteersalternating-currentTorqueperceived discomfortFemalefatigueduty-cyclebusinessAlternating current030217 neurology & neurosurgeryBiomedical engineering
researchProduct

Study of spindle-spike interactions: Features of basal ganglia control

1987

Summary Changes in cortical spindle distribution following penicillin (PCN) injections were studied in feline generalized PCN epilepsy. PCN activation caused no substantial changes in spindle duration, frequency and intraburst frequency, while significant reductions in the amplitude of the negative waves were noted. At the same time combinations of spindle waves and epileptic complexes were recorded with one or more spikes randomly occurring at the beginning, in the middle, or at the end of a spindle envelope. Low frequency stimulation of the caudate nucleus induced a certain degree of enhancement in cortical precruciate spike frequency while high frequency activation of the entopeduncular …

MalePhysiologyCaudate nucleusPenicillinsElectroencephalographyGlobus PallidusBasal GangliaEpilepsySpike frequencyBasal gangliamedicineAnimalsLow frequency stimulationCerebral CortexDecerebrate StateEpilepsymedicine.diagnostic_testChemistryElectroencephalographymedicine.diseaseElectric StimulationSpindle envelopeCatsFemaleNeurology (clinical)Caudate NucleusNeuroscienceEntopeduncular nucleusRevue d&'apos;Electroencéphalographie et de Neurophysiologie Clinique
researchProduct

Acute inactivation of the medial forebrain bundle imposes oscillations in the SNr: a challenge for the 6-OHDA model?

2010

It has been recently shown that the substantia nigra pars reticulata (SNr) of 6-hydroxydopamine (6-OHDA)-lesioned rats, under urethane anaesthesia, manifests a prominent low frequency oscillation (LFO) of around 1Hz, synchronized with cortical slow wave activity (SWA). Nevertheless, it is poorly understood whether these electrophysiological alterations are correlated only with severe dopamine depletion or may also play a relevant pathogenetic role in the early stages of the dopamine denervation. Hence, here we recorded SNr single units and electrocorticogram (ECoG) in two models of dopamine denervation: (i) acute dopamine denervated rats, obtained by injection of tetrodotoxin (TTX), (ii) ch…

MaleTyrosine 3-Monooxygenasebasal ganglia oscillationsDopamineParkinson's diseaseWistarAction PotentialsParkinson's disease; Low frequency oscillation basal ganglia oscillations; Medial forebrain bundle; Tetrodotoxin; ElectrocorticogramTetrodotoxinSettore BIO/09 - FisiologiaParkinson's disease; low frequency oscillation; basal ganglia oscillations; medial forebrain bundle; Tetrodotoxin; electrocorticogramStatistics NonparametricAnimals; Analysis of Variance; Action Potentials; Electrophysiology; Tyrosine 3-Monooxygenase; Cerebral Cortex; Rats; Biological Clocks; Dopamine; Neurons; Rats Wistar; Substantia Nigra; Immunohistochemistry; Medial Forebrain Bundle; Statistics Nonparametric; MaleMedial forebrain bundlechemistry.chemical_compoundDevelopmental NeuroscienceBiological ClocksDopamineBasal gangliamedicineAnimalsNonparametricRats WistarMedial forebrain bundleElectrocorticographyCerebral CortexNeuronsDenervationAnalysis of Variancemedicine.diagnostic_testChemistryStatisticsLow frequency oscillation basal ganglia oscillationElectrocorticogramImmunohistochemistryRatsCortex (botany)ElectrophysiologySubstantia NigraElectrophysiologynervous systemNeurologylow frequency oscillationTetrodotoxinSettore MED/26 - NeurologiaNeurosciencemedicine.drug
researchProduct

Neuromuscular Adaptations to Low-Frequency Stimulation Training in a Patient with Chronic Heart Failure

2008

Electrical myostimulation (EMS) has recently been proposed as an interesting rehabilitation tool in patients with chronic heart failure (CHF). Although its beneficial effects on exercise capacity and muscle strength have been demonstrated, the neuromuscular adaptations responsible for improved performance are not well understood. This preliminary case report was therefore planned to investigate the neural and muscular adaptations to a 5-wk EMS program in one patient. An increase in maximal strength (10.5%) was accompanied by increased twitch torque (13.9%) and slowing of muscle contractile properties (half-relaxation time, time to peak torque, and maximal rate of relaxation increased by 7.1…

Malemedicine.medical_specialtymedicine.medical_treatmentPhysical Therapy Sports Therapy and RehabilitationPhysical medicine and rehabilitationHumansMedicineIn patientMuscle SkeletalLow frequency stimulationHeart FailureLegRehabilitationRelaxation (psychology)Electromyographybusiness.industryRehabilitationHeartStroke VolumeMuscle activationMiddle Agedmedicine.diseaseAdaptation PhysiologicalMyocardial ContractionElectric StimulationImproved performanceTorqueHeart failureFeasibility StudiesTime to peakCardiomyopathiesbusinessAmerican Journal of Physical Medicine & Rehabilitation
researchProduct

Thickness sensitivity of ultrasound velocity in long bone phantoms

2004

One approach to bone disease diagnosis such as osteoporosis is to measure the velocity of ultrasound propagating axially along long bones. In this study, the variation in velocity as a function of radial position was assessed using two polyvinyl chloride (PVC) bone phantoms with cross-sectional geometry similar to the human tibia but differing in medullary cavity diameter. Two ultrasonometers were used: these were a commercial device operating at a relatively high frequency (HF) of 1.25 MHz and a prototype low frequency (LF) device operating at approximately 200 kHz. The LF measurements showed a larger variation with radial position, with changes in velocity of up to 20% occurring around th…

Materials scienceAcoustics and UltrasonicsBone diseaseMedullary cavityLong boneBiophysicsLow frequencyBone and BonesImaging phantommedicineHumansUltrasonicsRadiology Nuclear Medicine and imagingTibiaPolyvinyl ChlorideUltrasonographyTibiaRadiological and Ultrasound TechnologyPhantoms Imagingbusiness.industryUltrasoundAnatomymedicine.diseasemedicine.anatomical_structureOsteoporosisbusinessAxial symmetryBiomedical engineeringUltrasound in Medicine & Biology
researchProduct

Low-frequency band gap in cross-like holey phononic crystal strip

2018

International audience; A silicon-based cross-like holey phononic crystal (PnC) strip is proposed for the control of elastic waves in the field of micro-electro-mechanical systems (MEMS). The goal is to obtain a broad bandgap at low frequencies with a lightweight structure. In this respect, the effects of varying the in-plane and the out-of-plane geometry parameters are discussed. After design, a gap-to-midgap ratio of 47% is obtained with an intermediate filling fraction of the solid material and a small thickness of the strip. The band gap can be moved to an extremely low frequency range while keeping the strip significantly smaller than previously reported PnC strips. The transmission pr…

Materials scienceAcoustics and UltrasonicsSiliconBand gapchemistry.chemical_element02 engineering and technologySTRIPS01 natural scienceslaw.invention[SPI.MAT]Engineering Sciences [physics]/MaterialsCrystalResonatorlaw0103 physical sciencesExtremely low frequency[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsElectronic band structure010302 applied physicsMicroelectromechanical systems[SPI.ACOU]Engineering Sciences [physics]/Acoustics [physics.class-ph]business.industry021001 nanoscience & nanotechnologyCondensed Matter PhysicsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialschemistryOptoelectronics0210 nano-technologybusiness
researchProduct

Characterization of Different Cable Ferrite Materials to Reduce the Electromagnetic Noise in the 2–150 kHz Frequency Range

2018

The gap of standardization for conducted and field coupled electromagnetic interferences (EMI) in the 2–150 kHz frequency range can lead to Electromagnetic Compatibility (EMC) problems. This is caused by power systems such as Pulse Width Modulation (PWM) controlled rectifiers, photovoltaic inverters or charging battery units in electric vehicles. This is a very important frequency spectral due to interferences generated in a wide range of devices and, specifically, communication problems in the new technologies and devices incorporated to the traditional grid to convert it into a Smart Grid. Consequently, it is necessary to provide new solutions to attenuate this kind of interference, which…

Materials scienceAcoustics02 engineering and technology01 natural scienceslcsh:TechnologyArticlelow frequency emissionsElectric power systeminsertion lossEMI0103 physical sciencescable ferriteInsertion lossGeneral Materials Sciencelcsh:MicroscopyElectrical impedancelcsh:QC120-168.85010302 applied physicscable ferrite; electromagnetic interferences; low frequency emissions; nanocrystalline; relative permeability; insertion losselectromagnetic interferenceslcsh:QH201-278.5lcsh:TPhotovoltaic systemElectromagnetic compatibilityrelative permeability021001 nanoscience & nanotechnologylcsh:TA1-2040Ferrite (magnet)lcsh:Descriptive and experimental mechanicsnanocrystallinelcsh:Electrical engineering. Electronics. Nuclear engineering0210 nano-technologylcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971Pulse-width modulationMaterials; Volume 11; Issue 2; Pages: 174
researchProduct