Search results for "Luminol"

showing 10 items of 21 documents

Molecular Basis of the Chemiluminescence Mechanism of Luminol

2019

Light emission from luminol is probably one of the most popular chemiluminescence reactions due to its use in forensic science, and has recently displayed promising applications for the treatment of cancer in deep tissues. The mechanism is, however, very complex and distinct possibilities have been proposed. By efficiently combining DFT and CASPT2 methodologies, the chemiluminescence mechanism has been studied in three steps: 1)luminol oxygenation to generate the chemiluminophore, 2)a chemiexcitation step, and 3)generation of the light emitter. The findings demonstrate that the luminol double-deprotonated dianion activates molecular oxygen, diazaquinone is not formed, and the chemiluminopho…

CASPT2010405 organic chemistryChemistryOrganic ChemistryGeneral Chemistryelectron transfer010402 general chemistryPhotochemistry01 natural scienceschemiluminescenceCatalysis0104 chemical sciencesLuminollaw.inventionreaction mechanismschemistry.chemical_compoundlawdensity functional calculationsTeoretisk kemicancerLight emissionTheoretical ChemistryChemiluminescenceChemistry – A European Journal
researchProduct

Calibration transfer in chemiluminescence analysis

2001

Abstract Direct standardization (DS) and piecewise direct standardization (PDS) methods are applied to multivariate standardization of chemiluminescence signals using PLS model as the calibration model. The linear concentration interval of the chemiluminescence determination was determined. This interval was located using univariate robust calibration by least median of squares (LMS) method. The linear calibration model was corroborated by conventional least-squares method. The standardization subset and window size were optimized by means of the prediction residual error sum of squares. Several instrumental sources of variability have been studied: the detection cell, instrument, batch ver…

Calibration (statistics)Explained sum of squaresFluorescence spectrometryAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionLuminolChemometricschemistry.chemical_compoundchemistrylawLinear regressionEnvironmental ChemistryQuantitative analysis (chemistry)SpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct

Indirect determination of paracetamol in pharmaceutical formulations by inhibition of the system luminol–H2O2–Fe(CN)63− chemiluminescence

1999

After a large drug scanning, the system Luminol-H2O2-Fe(CN)6(3-) is proposed for first time for the indirect determination of paracetamol. The method is based on the oxidation of paracetamol by hexacyanoferrate (III) and the subsequent inhibitory effect on the reaction between luminol and hydrogen peroxide. The procedure resulted in a linear calibration graph over the range 2.5-12.5 microg ml(-1) of paracetamol with a sample throughput of 87 samples h(-1). The influence of foreign compounds was studied and, the method was applied to determination of the drug in three different pharmaceutical formulations.

ChromatographyCalibration curveClinical BiochemistryAnalgesicAnalytical chemistryPharmaceutical ScienceDosage formAnalytical ChemistryLuminollaw.inventionchemistry.chemical_compoundchemistrylawDrug DiscoveryFerricyanideHydrogen peroxideQuantitative analysis (chemistry)SpectroscopyChemiluminescenceJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Accuracy, Reliability, and Safety of Luminol in Bloodstain Investigation

2002

ABSTRACTThe reliability of luminol as a presumptive test reagent was studied in this work. The possibility of obtaining a false negative subsequent to contamination of the test specimen was determined. The behavior of luminol with respect to a contaminant was compared to other reagents used in similar tests. Following an analysis of the test results, other test sensitivity, and safety data, it was concluded that luminol is a more reliable reagent than others due to a higher improbability of producing false positives and false negatives, apart from being safer than other substances. It should, therefore, be considered as a “preferable” or “first choice” reagent for use in presumptive tests.

ChromatographyInjury controlAccident preventionbusiness.industryFalse positives and false negativesEnvironmental engineeringnutritional and metabolic diseasesPoison controlchemical and pharmacologic phenomenaTest sensitivityPathology and Forensic MedicineLuminolchemistry.chemical_compoundchemistryReagentMedicinebusinessReliability (statistics)Canadian Society of Forensic Science Journal
researchProduct

Inhibition of the system luminol-H2O2-Fe(CN)63− chemiluminescence by the Mn(II) indirect determination of isoniazid in a pharmaceutical formulation

1998

A flow injection procedure for the indirect chemiluminescent determination of isoniazid is proposed. The method is performed in a flow-injection manifold provided with a solid-phase reactor. The reactor was made from manganese dioxide physically entrapped by polymerization; the redox reaction isoniazid-manganese dioxide released Mn(II) which was monitored through its inhibitory effect on the reaction between luminol and hydrogen peroxide in presence of potassium hexacyanoferrate (III). The procedure resulted in a linear calibration graph over the range 5-15 mg/L of isoniazid with a sample throughput of 43 samples/h. The influence of foreign compounds was studied and the method was applied t…

ChromatographyPotassiumBiophysicschemistry.chemical_elementManganesePharmaceutical formulationRedoxlaw.inventionLuminolchemistry.chemical_compoundchemistryPolymerizationChemistry (miscellaneous)lawHydrogen peroxideChemiluminescenceNuclear chemistryJournal of Bioluminescence and Chemiluminescence
researchProduct

A new flow cell design for chemiluminiscence analysis.

2001

The present study proposes a new flow cell called a bundle cell for chemiluminescence analysis. The results obtained were compared with those achieved by manual and automated batch procedures and flow manifolds with different cells: an common quartz flow cell, a helix cell and the most used spiral cell. Figures of merit such as limit of detection, sensitivity, accuracy and precision for the Cr(III) determination were established with light emission produced by catalysed Cr(III) luminol oxidation by hydrogen peroxide in a basic aqueous solution. An improvement in sensitivity about 50% as compared with the spiral cell and even larger with respect to the other flow cells tested was observed. T…

Detection limitAccuracy and precisionAqueous solutionChemistryAnalytical chemistryMineralogyAnalytical ChemistryLuminollaw.inventionchemistry.chemical_compoundFlow (mathematics)lawBatch processingLight emissionChemiluminescenceTalanta
researchProduct

A portable and low cost equipment for flow injection chemiluminescence measurements.

2004

A compact, reliable and low cost flow injection chemiluminescence system is described. The flow system consists of a set of solenoid micro-pumps that can dispense reproductive micro-volumes of solutions. The luminometer was based on a coiled cell constructed from polyethylene tubing that was sandwiched between two large area photodiodes. The whole equipment costs about US$ 750 and weights ca. 3 kg. Equipment performance was evaluated by measuring low concentrations of hydrogen peroxide by oxidation of luminol and for the determination of ammonium, based on its inhibition of the luminescence provided by the reaction of luminol and sodium hypochlorite. Linear responses were achieved within 1.…

Detection limitChemistryAnalytical chemistryHypochloriteAnalytical ChemistryLuminollaw.inventionchemistry.chemical_compoundlawReagentSodium hypochloriteHydrogen peroxideLuminescenceChemiluminescenceTalanta
researchProduct

Chemiluminescent method for detection of eutrophication sources by estimation of organic amino nitrogen and ammonium in water.

2006

An automatic method has been developed for the estimation of organic amino nitrogen (CH2-NH) and ammonium in water samples. We propose a continuous flow system in which nitrogen compounds react with hypochlorite reagent to produce chloramines. Subsequently, the mixture is mixed with luminol, generating a chemiluminescence signal. The signal emission at 425 nm, registered as a function of time, decreases as nitrogen concentration increases, due to the decrease on hypochlorite concentration. A large number of nitrogen compounds have been assayed and their sensitivities compared, in milligrams per liter nitrogen. The ammonium calibration graph, expressed as N, can be used for most of the assay…

Detection limitChloramineChromatographyMineralogychemistry.chemical_elementHypochloriteNitrogenAnalytical Chemistrylaw.inventionLuminolStandard curvechemistry.chemical_compoundchemistrylawAmmoniumChemiluminescenceAnalytical chemistry
researchProduct

A chemiluminescence flow-based procedure for determination of carbaryl in natural waters exploiting multicommutation and enzymatic reaction

2007

A chemiluminescence procedure for the determination of carbaryl in natural waters using acetylcholinesterase and choline oxidase is described. The flow system designed to implement multicommutation approach controlled by microcomputer comprised five solenoid valves, two columns with immobilized enzymes on controlled pore glass beads and chemiluminometric flow cell. In the best experimental conditions a linear response ranging from 25 to 700 µg L-1 carbaryl was obtained. Water samples were spiked with carbaryl in order to access the accuracy and recoveries between 95 and 101% were obtained for a concentration level ranging from 25 to 100 µg L-1 carbaryl. Detection limit and variation coeffic…

Detection limitChromatographyImmobilized enzymeChemistryPotassiumchemistry.chemical_elementGeneral ChemistryCholine oxidasechemiluminescenceLuminollaw.inventionpesticide carbarylchemistry.chemical_compoundmulticommutationlawReagentCarbarylflow analysisChemiluminescenceenzymatic reaction
researchProduct

New Reusable Solid Biosensor with Covalent Immobilization of the Horseradish Peroxidase Enzyme: In Situ Liberation Studies of Hydrogen Peroxide by Po…

2019

Herein, we reported a chemiluminescent biosensor based on the covalent immobilization of the horseradish peroxidase (HRP) enzyme on a polydimethylsiloxane (PDMS) support to quantify in situ hydrogen peroxide (H2O2). The chemiluminescent reaction based on the use of luminol as an oxidizable substrate, with HRP as the catalyst, has been used in order to quantify H2O2 as the oxidizing agent. The performance of the proposed biosensor has been demonstrated to determine H2O2 liberated by cells in a culture medium and for evaluating the delivery of H2O2 from denture cleaner tablets, as examples of application. For both analyses, the results indicated that the biosensor is cost-effective, sensitive…

Detection limitChromatographybiologyGeneral Chemical EngineeringSubstrate (chemistry)General ChemistryHorseradish peroxidaseArticleLuminollaw.inventionchemistry.chemical_compoundChemistrychemistrylawOxidizing agentbiology.proteinHydrogen peroxideBiosensorQD1-999ChemiluminescenceACS omega
researchProduct