Search results for "MPL"
showing 10 items of 21777 documents
Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Pa…
2019
Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years functional loading. Materials and Methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (Group GS); cemented crown without finishing line (biologically oriented preparation technique) (Group GBOPT); and conventional cemented crown with finishing line (Group GCC). The clinical behavior of each restoration type was analyzed after 3 years functional loading by analyzing radiographic peri-implant b…
Two-qubit entanglement dynamics for two different non-Markovian environments
2009
We study the time behavior of entanglement between two noninteracting qubits each immersed in its own environment for two different non-Markovian conditions: a high-$Q$ cavity slightly off-resonant with the qubit transition frequency and a nonperfect photonic band-gap, respectively. We find that revivals and retardation of entanglement loss may occur by adjusting the cavity-qubit detuning, in the first case, while partial entanglement trapping occurs in non-ideal photonic-band gap.
Testing of wireless sensor performance in Vessel-to-Vessel Motion Compensation
2016
Relative Vessel-to-Vessel Motion Compensation (VVMC) between two floating vessels can be considered an extension of existing Active Heave Compensation (AHC), which is current state-of-the-art in the offshore industry. In this paper, the experimental results from a small-scale experimental setup of a VVMC scenario are presented. The work focuses on the kinematics related to VVMC, sensor accuracy of Motion Reference Units (MRUs), and the communication delay related to wireless transmission of MRU data between two floating vessels. The accuracies of the MRU sensors are good and verified to be less than 5% of the heave amplitude. The wireless communication link had a typical time-delay of 8ms. …
A time-varying observer for linear systems with asynchronous discrete-time measurements
2017
International audience; In this paper we propose a time-varying observer for a linear continuous-time plant with asynchronous discrete-time measurements. The proposed observer is contextualized in the hybrid systems framework providing an elegant setting for the proposed solution. In particular some theoretical tools are provided, in terms of LMIs, certifying asymptotic stability of a certain compact set where the estimation error is zero. Moreover the case of asynchronous measurements is considered, i.e. when the measurements are not provided in well defined time instants, but they occur at an arbitrary time in a certain time interval. A design procedure based on the numerical solution of …
The Comparison of Cellulolytic Activity of the Modified Soil Treated with Roundup
2016
Abstract The activity of soil microorganisms affects soil fertility and structure, what leads to satisfactory crop yields, thanks to changes in the decay of organic matter. Their activity may be impaired as a result of application by farmers both fertilizers and pesticides. The degradation of cellulosic biomass represents an important part of the carbon cycle within the biosphere. Cellulolitic microorganisms are responsible for this decomposition, as they produced the enzymes of the cellulase complex. The aim of the study was to compare the cellulolytic activity of soil with Roundup and modified using urea phosphate and / or manure. The pot experiment was conducted under laboratory conditio…
Combining GPU and FPGA technology for efficient exhaustive interaction analysis in GWAS
2016
Interaction between genes has become a major topic in quantitative genetics. It is believed that these interactions play a significant role in genetic variations causing complex diseases. Due to the number of tests required for an exhaustive search in genome-wide association studies (GWAS), a large amount of computational power is required. In this paper, we present a hybrid architecture consisting of tightly interconnected CPUs, GPUs and FPGAs and a fine-tuned software suite to outperform other implementations in pairwise interaction analysis while consuming less than 300Watts and fitting into a standard desktop computer case.
BIOAEROSOL
2017
Cultural heritage constitutive materials can provide excellent substrates for microbial colonisation, highly influenced by thermo-hygrometric parameters. In cultural heritage-related environments, a detrimental microbial load may be present both on manufact surface and in the aerosol. Confined environments (museums, archives, deposits, caves, hypogea) have peculiar structures and dif- ferent thermo-hygrometric parameters, influencing the development of a wide range of microbial species, able to induce artefact biodeterioration and to release biological particles in the aerosol (spores, cellular debrides, toxins, allergens) potentially dangerous for the human health (visitors/users). In orde…
Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.
2017
Cadmium-zinc-telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2â...mm-thick CZT pixel detector, with pixel pitches of 500 and 250â...μm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response …
Dual-polarity pulse processing and analysis for charge-loss correction in cadmium–zinc–telluride pixel detectors
2018
Charge losses at the inter-pixel gap are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. In this work, an original technique able to correct charge losses occurring after the application of charge-sharing addition (CSA) is presented. The method, exploiting the strong relation between the energy after CSA and the beam position at the inter-pixel gap, allows the recovery of charge losses and improvements in energy resolution. Sub-millimetre CZT pixel detectors were investigated with both uncollimated radiation sources and collimated synchrotron X-rays, at energies below and above the K-shell absorption energy of the CZT material. The detectors are DC coupled to fast and low…
Clinical effect of diode laser on peri-implant tissues during non-surgical peri-implant mucositis therapy: Randomized controlled clinical study
2019
Background: The aim of this study is to evaluate the response to the non-surgical treatment of peri-implant mucositis using the diode laser as an adjuvant therapy in patients with implant-supported restorations, in terms of clinical variables, with respect to those patients in whom conventional non-surgical therapy is used. Material and Methods: Randomized controlled clinical trial with simple blind 3 months follow-up. Two groups of patients were established, the non-surgical mechanical debridement of the affected implants was performed in the control group (n = 34) and the diode laser therapy was also performed in the test group (n = 34). The implant was considered the study subject; the v…