Search results for "Magnetic fields"

showing 10 items of 217 documents

No effects of mobile phone use on cortical auditory change-detection in children: an ERP study

2010

We investigated the effect of mobile phone use on the auditory sensory memory in children. Auditory event-related potentials (ERPs), P1, N2, mismatch negativity (MMN), and P3a, were recorded from 17 children, aged 11–12 years, in the recently developed multi-feature paradigm. This paradigm allows one to determine the neural change-detection profile consisting of several different types of acoustic changes. During the recording, an ordinary GSM (Global System for Mobile Communications) mobile phone emitting 902 MHz (pulsed at 217 Hz) electromagnetic field (EMF) was placed on the ear, over the left or right temporal area (SAR1g = 1.14 W/kg, SAR10g = 0.82 W/kg, peak value = 1.21 W/kg). The EMF…

Malemedicine.medical_specialtyTime FactorsPhysiologyComputer sciencemedia_common.quotation_subjectBiophysicsMismatch negativityAudiologyNeuropsychological TestsFunctional Laterality030218 nuclear medicine & medical imaging03 medical and health sciencesP3a0302 clinical medicineElectromagnetic FieldsGSMMemoryPerceptionmedicineHumansRadiology Nuclear Medicine and imagingSingle-Blind MethodChildBioelectromagneticsmedia_commonSensory memoryBrainTemporal BoneEarElectroencephalographyGeneral MedicineAcoustic StimulationMobile phoneCellular PhoneAuditory PerceptionEvoked Potentials AuditoryFemale030217 neurology & neurosurgeryChange detectionCell Phone
researchProduct

1 Hz repetitive transcranial magnetic stimulation of the unaffected hemisphere ameliorates contralesional visuospatial neglect in humans

2002

The aim of the study was to investigate whether low-frequency repetitive transcranial magnetic stimulation (rTMS) over the unaffected hemisphere can ameliorate visuospatial neglect. We treated three right brain damaged patients with left neglect. 900 pulses (1 Hz frequency) were given over left posterior parietal cortex every other day for 2 weeks. Patients performed a computerized task requiring length judgement of prebisected lines, tachistoscopically presented for 150 ms. With respect to rTMS the task was given 15 days before, at the beginning, at the end and 15 days after. At these times patients performed also line bisection and clock drawing tasks. rTMS induced a significant improveme…

Malemedicine.medical_specialtyVisual perceptionmedia_common.quotation_subjectmedicine.medical_treatmentPosterior parietal cortexVisuospatial neglectNeurological disorderAudiologybehavioral disciplines and activitiesLateralization of brain functionBrain IschemiaNeglectPerceptual DisordersElectromagnetic FieldsParietal LobemedicineHumansAgedmedia_commonGeneral NeuroscienceMiddle AgedEvoked Potentials Motormedicine.diseaseTranscranial magnetic stimulationTreatment OutcomeSpace PerceptionCerebral hemisphereAgnosiaVisual PerceptionPsychologyNeurosciencePsychomotor Performancepsychological phenomena and processesNeuroscience Letters
researchProduct

A case study of Primary Progressive Aphasia: improvement on verbs after rTMS treatment.

2006

This case-report shows that high frequency repetitive Transcranial Magnetic Stimulation (hf-rTMS), applied to the left prefrontal cortex, may improve the linguistic skills in Primary Progressive Aphasia (PPA). The patient's performance was evaluated on a battery of language production and memory span tasks, before and after two hf-rTMS treatments and one SHAM treatment. We observed a significant and lasting improvement of the patient's performance on verb production following the application of hf-rTMS versus Baseline and SHAM conditions. This finding suggests that hf-rTMS may directly strengthen the neural connections within an area of metabolic dysfunction and encourages the use of rTMS a…

Malemedicine.medical_specialtymedicine.medical_treatmentPrefrontal CortexVerbbehavioral disciplines and activitiesSettore BIO/09 - FisiologiaPrimary progressive aphasiaPhysical medicine and rehabilitationElectromagnetic FieldsArts and Humanities (miscellaneous)MemoryAphasiarTMSNeural PathwaysmedicineMemory spanHumansLanguageMemory DisordersLanguage TestsLanguage productionSettore M-PSI/02 - Psicobiologia E Psicologia FisiologicaVerbal BehaviorLinguistic skillsMiddle Agedmedicine.diseaseMagnetic Resonance ImagingTranscranial Magnetic StimulationPrimary Progressive AphasiaTranscranial magnetic stimulationAphasia Primary ProgressiveTreatment Outcomenervous systemLeft prefrontal cortexSettore MED/26 - NeurologiaNeurology (clinical)medicine.symptomAtrophyPsychologyPPANeurosciencepsychological phenomena and processesNeurocase
researchProduct

Iris-Like Tunable Aperture Employing Liquid-Crystal Elastomers

2014

A liquid-crystal elastomer (LCE) iris inspired by the human eye is demonstrated. With integrated polyimide-based platinum heaters, the LCE material is thermally actuated. The radial contraction direction, similar to a mammalian iris, is imprinted to the LCE by a custom-designed magnetic field. Actuation of the device is reproducible over multiple cycles and controllable at intermediate contraction states.

Materials scienceAperturePlatinum CompoundsLiquid crystal elastomerEyeElastomerBenzoatesOpticsBiomimetic MaterialsmedicineHumansGeneral Materials Sciencebusiness.industryMechanical Engineeringfemale genital diseases and pregnancy complicationsLiquid CrystalsMagnetic fieldMagnetic Fieldsmedicine.anatomical_structureAcrylatesElastomersMechanics of MaterialsHuman eyeIRIS (biosensor)businessMagnetic orientationPolyimideAdvanced Materials
researchProduct

The electron cyclotron resonance ion source with arc-shaped coils concept

2012

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cos…

Materials scienceIon beamOptical PhenomenaPlasma Gasesta114Highly charged ionCyclotron resonanceTemperatureParticle acceleratorElectronsCyclotronsModels TheoreticalIon gunIon sourceElectron cyclotron resonancelaw.inventionMagnetic FieldslawAtomic physicsInstrumentationIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Features of randomized electric-field assisted domain inversion in lithium tantalate

2011

We report on bulk and guided-wave second-harmonic generation via random Quasi-Phase-Matching in Lithium Tantalate. By acquiring the far-field profiles at several wavelengths, we extract statistical information on the distribution of the quadratic nonlinearity as well as its average period, both at the surface and in the bulk of the sample. By investigating the distribution in the two regions we demonstrate a non-invasive approach to the study of poling dynamics.

Materials scienceLightNonlinear opticFOS: Physical sciencesTantalumLithiumSettore ING-INF/01 - Elettronicachemistry.chemical_compoundElectromagnetic FieldsElectric fieldScattering RadiationComputer SimulationQuadratic nonlinearityPolingSettore ING-INF/02 - Campi ElettromagneticiOxidesInversion (meteorology)Equipment DesignModels TheoreticalHarmonic generation and mixingAtomic and Molecular Physics and OpticsComputational physicsEquipment Failure AnalysisRefractometryWavelengthchemistryLithium tantalateComputer-Aided DesignOptics (physics.optics)Physics - Optics
researchProduct

Temperature- and Magnetic-Field-Dependent Longitudinal Spin Relaxation in Nitrogen-Vacancy Ensembles in Diamond

2011

We present an experimental study of the longitudinal electron-spin relaxation time (T1) of negatively charged nitrogen-vacancy (NV) ensembles in diamond. T1 was studied as a function of temperature from 5 to 475 K and magnetic field from 0 to 630 G for several samples with various NV and nitrogen concentrations. Our studies reveal three processes responsible for T1 relaxation. Above room temperature, a two-phonon Raman process dominates, and below, we observe an Orbach-type process with an activation energy, 73(4) meV, which closely matches the local vibrational modes of the NV center. At yet lower temperatures, sample dependent cross relaxation processes dominate, resulting in temperature …

Materials scienceNitrogenFOS: Physical sciencesGeneral Physics and Astronomy02 engineering and technologyActivation energyengineering.materialSpectrum Analysis Raman01 natural sciencessymbols.namesakeVacancy defect0103 physical sciences010306 general physicsCondensed Matter - Materials ScienceCondensed matter physicsTemperatureSpin–lattice relaxationMaterials Science (cond-mat.mtrl-sci)DiamondModels Theoretical021001 nanoscience & nanotechnologyMagnetic fieldMagnetic FieldsMolecular vibrationengineeringsymbolsDiamond0210 nano-technologyRaman spectroscopyOrder of magnitudePhysical Review Letters
researchProduct

Analysis of multipactor RF breakdown in a waveguide containing a transversely magnetized ferrite

2016

In this paper, the multipactor RF breakdown in a parallel-plate waveguide partially filled with a ferrite slab magnetized normal to the metallic plates is studied. An external magnetic field is applied along the vertical direction between the plates in order to magnetize the ferrite. Numerical simulations using an in-house 3-D code are carried out to obtain the multipactor RF voltage threshold in this kind of structures. The presented results show that the multipactor RF voltage threshold at certain frequencies becomes considerably lower than for the corresponding classical metallic parallel-plate waveguide with the same vacuum gap

Materials scienceSaturation magnetizationElectromagnetic waveguidesPhysics::Instrumentation and DetectorsIn-house 3D codeTransversely magnetized ferrite01 natural sciencesVacuum gap010305 fluids & plasmasExternal magnetic fieldOptics0103 physical sciencesVertical directionRadio frequencyTEORIA DE LA SEÑAL Y COMUNICACIONESParallel-plate waveguideElectronic engineeringNumerical simulationsElectrical and Electronic EngineeringMagnetic anisotropyElectric breakdownMultipactor RF breakdown analysis010302 applied physicsbusiness.industryParallel plate waveguidesFerrite slabRF breakdownMicrowave switchesVacuum gapElectronic Optical and Magnetic MaterialsMagnetic fieldMultipactor RF voltage thresholdMagnetic fieldMetallic platesMagnetic fieldsSlabFerrite (magnet)Ferrite waveguidesFerrite devicesMultipactor effectbusinessVoltageNumerical analysis
researchProduct

A multi-sphere particle numerical model for non-invasive investigations of neuronal human brain activity

2013

In this paper, a multi-sphere particle method is built- up in order to estimate the solution of the Poisson's equation with Neumann boundary conditions describing the neuronal human brain activity. The partial difierential equations governing the relationships between neural current sources and the data produced by neuroimaging technique, are able to compute the scalp potential and magnetic fleld distributions generated by the neural activity. A numerical approach is proposed with current dipoles as current sources and going on in the computation by avoiding the mesh construction. The current dipoles are into an homogeneous spherical domain modeling the head and the computational approach i…

Mathematical optimizationCurrent (mathematics)Quantitative Biology::Neurons and CognitionComputer scienceComputationNon invasiveMathematical analysisDomain modelPoisson distributionElectronic Optical and Magnetic MaterialsDipolesymbols.namesakeBio-magnetic fields Human brain activity meshless numerical methodSettore ING-IND/31 - ElettrotecnicaNeumann boundary conditionsymbolsParticle
researchProduct

Extremely low frequency magnetic fields in residences in Germany. Distribution of measurements, comparison of two methods for assessing exposure, and…

2001

We examined the results of 1,835 magnetic field measurements in German residences conducted between November 1997 and September 1999. The measurements were part of an epidemiological study on the relationship between magnetic fields and childhood leukemia. We performed a fixed-location measurement of the magnetic field at 50 Hz and 16 2/3 Hz (frequency of the German railway system) over 24 h in the child's bedroom in the residence of each study participant. In addition, we conducted a second 24 h-measurement in the living room at 50 Hz, and spot measurements while walking through all rooms of the respective dwelling. Median 50 Hz magnetic fields above 0.2 muT were found to be infrequent in …

Measurement methodRadiationModels StatisticalTime FactorsField (physics)BiophysicsEnvironmental ExposureLiving roomPositive correlationGeodesyBackground levelMagnetic fieldNuclear magnetic resonanceElectromagnetic FieldsRisk FactorsGermanyHousingOdds RatioEnvironmental scienceHumansExtremely low frequencyChildGeneral Environmental ScienceArithmetic meanEnvironmental MonitoringRadiation and environmental biophysics
researchProduct