Search results for "Materials Testing"
showing 10 items of 254 documents
Coupled stochastic dynamics of magnetic moment and anisotropy axis of a magnetic nanoparticle
2012
An algorithm is developed for numerical simulation of coupled stochastic dynamics of magnetic moment and magnetic anisotropy axis of a nanoparticle. Time-correlation functions of the magnetic moment and its components longitudinal and transverse to the magnetic anisotropy axis are calculated by averaging along the stochastic trajectory. The longitudinal and transverse relaxation times are found by fitting the time correlation functions. Existing theoretical relations derived by the effective field approach in the limit of small fields are confirmed. The time-correlation functions of magnetic moments of nanoparticles in dependence on their properties are calculated numerically for arbitrary …
Self-assembling and auto-crosslinkable hyaluronic acid hydrogels with a fibrillar structure
2008
Abstract A hyaluronic acid derivative bearing pendant l -benzoyl-cysteine portions (with a derivatization degree equal to 10 mol.%) was synthesized by linking N,N′-dibenzoyl- l -cystine to the polysaccharide and then reducing its disulfide bridge to thiol groups. The formation of π–π stacking interactions between the benzoyl moieties was studied by fluorescence spectroscopy as a function of polymer concentration and oxidation time. The efficiency of oxidation of thiol groups to disulfide bridges occurring in phosphate buffer pH 7.4, was determined by colorimetric assays. The hydrogel formed by means of oxidative crosslinking has shown the presence of fibrillar aggregates as detected by ligh…
Epiphany root canal sealer prepared with resinous solvent is irritating to rat subcutaneous tissues.
2011
Objective: This study assessed the biocompatibility of the Epiphany endodontic sealer prepared with resinous solvent of Epiphany system (Thinning resin) in rat subcutaneous tissues. Study Design: Polyethylene tubes were filled with the sealer and 4 groups were established: GI, Epiphany prepared with 1 drop of resinous solvent (RS); GII, Epiphany prepared with 1 drop of RS and photoactivated; GIII, Epiphany associated with self-etch primer and prepared with 1 drop of RS; GIV, Epiphany associated with self-etch primer, prepared with 1 drop of RS and photoactivated. The filled tubes were implanted into 4 different regions of the dorsum of 20 adult male rats. Results: After 7, 14 and 21 days, a…
Improving cytocompatibility of Co28Cr6Mo by TiO 2 coating: gene expression study in human endothelial cells
2013
Cobalt-based materials are widely used for coronary stents, as well as bone and joint implants. However, their use is associated with high corrosion incidence. Titanium alloys, by contrast, are more biocompatible owing to the formation of a relatively inactive titanium oxide (TiO 2 ) layer on their surface. This study was aimed at improving Co28Cr6Mo alloy cytocompatibility via sol–gel TiO 2 coating to reduce metal corrosion and metal ion release. Owing to their role in inflammation and tissue remodelling around an implant, endothelial cells present a suitable in vitro model for testing the biological response to metallic materials. Primary human endothelial cells seeded on Co28Cr6Mo showe…
Evaluation of the tissue reaction to a new bilayered collagen matrix in vivo and its translation to the clinic.
2011
This study evaluates a new collagen matrix that is designed with a bilayered structure in order to promote guided tissue regeneration and integration within the host tissue. This material induced a mild tissue reaction when assessed in a murine model and was well integrated within the host tissue, persisting in the implantation bed throughout the in vivo study. A more porous layer was rapidly infiltrated by host mesenchymal cells, while a layer designed to be a barrier allowed cell attachment and host tissue integration, but at the same time remained impermeable to invading cells for the first 30 days of the study. The tissue reaction was favorable, and unlike a typical foreign body respons…
In situ crosslinkable hyaluronan hydrogels for tissue engineering
2003
We describe the development of an injectable, cell-containing hydrogel that supports cell proliferation and growth to permit in vivo engineering of new tissues. Two thiolated hyaluronan (HA) derivatives were coupled to four alpha,beta-unsaturated ester and amide derivatives of poly(ethylene glycol) (PEG) 3400. The relative chemical reactivity with cysteine decreased in the order PEG-diacrylate (PEGDA)>>PEG-dimethacrylate>PEG-diacrylamide>PEG-dimethacrylamide. The 3-thiopropanoyl hydrazide derivative (HA-DTPH) was more reactive than the 4-thiobutanoyl hydrazide, HA-DTBH. The crosslinking of HA-DTPH with PEGDA in a molar ratio of 2:1 occurred in approximately 9 min, suitable for an in situ cr…
The cytotoxic evaluation of mineral trioxide aggregate and bioaggregate in the subcutaneous connective tissue of rats
2013
Objectives: The purpose of this study was to evaluate and compare the cytotoxic effects of ProRoot MTA and DiaRoot BA, a bioceramic nanoparticulate cement, on subcutaneous rat tissue. Study D esign: Fifty Sprouge Dawley rats were used in this study. Polyethylene tubes filled with ProRoot MTA and DiaRoot BioAggregate, along with a control group of empty, were implanted into dorsal connective tissue of rats for 7, 15, 30, 60, and 90 days. After estimated time intervals the rats were sacrificed. The specimens were fixed, stained with hematoxylin and eosin, and then evaluated under a light microscope for inflammatory reactions and mineralization. Results: All groups evoked a severe to moderate …
New aspects in the histological examination of polyethylene wear particles in failed total joint replacements.
2002
The most important long-term complication in total joint replacements is aseptic osteolysis. Wear particles such as polyethylene (PE) debris are considered to be one of the causes that play a central role. Several studies indicated that PE can be visualised in paraffin-embedded tissue sections not only by polarised light, but also after oil red staining. To determine whether oil red staining enables sensitive detection of PE, we examined staining of mechanically-produced PE particles by oil red. Furthermore, we studied oil red staining of paraffin-embedded tissue specimens of patients with failed uncemented and cemented total knee and hip prostheses. We applied double labelling of sections …
Addition of blood to a phycogenic bone substitute leads to increased in vivo vascularization
2015
The present study aimed to analyze the effects of the addition of blood to the phycogenic bone substitute Algipore(®) on the severity of in vivo tissue reaction. Initially, Fourier-transform infrared spectroscopy (FTIR) of the bone substitute was conducted to analyze its chemical composition. The subcutaneous implantation model in Balb/c mice was then applied for up to 30 d to analyze the tissue reactions on the basis of specialized histochemical, immunohistochemical, and histomorphometrical methods. The data of the FTIR analysis showed that the phycogenic bone substitute material is mainly composed of hydroxyapatite with some carbonate content. The in vivo analyses revealed that the additi…