Search results for "Materials Testing"
showing 10 items of 254 documents
Tightness of duraplasty in rabbits: a comparative study.
2000
OBJECTIVE: The purpose of this study was to test, in rabbits, the tightness of seven dural substitution materials commonly used in neurosurgery, i.e., Lyodura (B. Braun Melsungen AG, Melsungen, Germany), Tutoplast dura (Tutogen Medical, Inc., Parsippany, NJ), Tutoplast fascia lata (Tutogen Medical, Inc.), autologous periosteum, Neuropatch (B. Braun Melsungen AG), Dacron (E.I. du Pont de Nemours and Co., Wilmington, DE), and Ethisorb (Ethicon, Inc., Somerville, NJ). METHODS: Duraplasties were performed with sutures alone or were additionally fixed with fibrin glue. Leakage pressures were assessed by infusion of artificial cerebrospinal fluid, containing sodium fluorescein, into the cisterna …
Evaluation of efficacy and biocompatibility of a novel semisynthetic collagen matrix as a dural onlay graft in a large animal model
2011
Background Semisynthetic collagen matrices are promising duraplasty grafts with low risk of cerebrospinal fluid (CSF) fistulas, good tissue integration and minor foreign body reaction. The present study investigates the efficacy and biocompatibility of a novel semisynthetic bilayered collagen matrix (BCM, B. Braun Aesculap) as dural onlay graft for duraplasty. Methods Thirty-four pigs underwent osteoclastic trepanation, excision of the dura, and placement of a cortical defect, followed by duraplasty using BCM, Suturable DuraGen™ (Integra Neuroscience), or periosteum. CSF tightness and intraoperative handling of the grafts were evaluated. Pigs were sacrificed after 1 and 6 months for histolo…
A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.
2004
OBJECTIVES To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN Basic science study. SETTING Experimental in vitro study. PATIENTS/PARTICIPANTS Forty fresh-frozen human distal humeri specimens. INTERVENTION Four matched groups with 10 humeri each, median age 74 years (46-95), were created using similar bone mineral density values. Two standard configurations of double-plate osteosynthesis (dorsal or 90 degrees configuration) with either conventional reconstruction plates or locking compression plates were studied for biomechanical properti…
Similar biomechanical properties of four tripled tendon graft models for ACL reconstruction
2021
Abstract Purpose The present study tested and compared the biomechanical properties of four different triplicate graft tendon techniques. Methods 32 tripled tendons from the common extensor muscle of bovine fingers were tested on a material testing machine, passing the end loop over a metal rod of a clevis connected to the load cell on the upper side, and fixing the lower end to a clamp. The samples were divided into four groups: (A) tripled with a free end sutured only to one of the two fixed bundles (B) tripled with a free end positioned between the two fixed strands and sutured to both (C) tripled with an S-shape and all the three strands sutured together at the upper and lower extremiti…
Suture needles in Oral Surgery: Alterations depending on the type and number of sutures
2011
This study examined whether the number and type of sutures used in oral surgery influence two ad hoc variables (incision plane and displaced area), which are two variables related to whether the suture needle is suitable for the task. Seventy-five TB-15 needles were studied, which were used to suture between zero and three mucosa and/subperiosteal sutures, producing 15 groups with 5 needles in each one. The incision plane and displaced area were measured for each group, which are two variables related to how the needle has worn and altered. Statistical treatment was conducted using the Kruskal-Wallis H test to compare multiple values and the Mann-Whitney U test to compare pairs. A multi-sta…
Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: A comparison of six diffe…
2012
Abstract Background An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. Methods New Zealand white rabbits were used for this study. Two meshes of the same brand (Ethicon Physiomesh™, Bard Composix ® L/P, Gore Dualmesh ® , Bard Sepramesh ® , Ethicon Proceed ® or Parietex™ Composite) were implanted into each animal for assessment of intra-abdominal hernia repair, with a total of ten meshes per group. Twelve weeks after implantation, the abdominal …
The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials
2008
The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after th…
Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.
2007
Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs.Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0…
The role of biosilica in the osteoprotegerin/RANKL ratio in human osteoblast-like cells
2010
Abstract Earlier studies have demonstrated that biosilica, synthesized by the enzyme silicatein, induces hydroxyapatite formation in osteoblast-like SaOS-2 cells. Here we study the effect of biosilica on the expressions of osteoprotegerin [OPG] and the receptor activator for NF-κB ligand [RANKL] in the SaOS-2 cell model. We show that during growth of SaOS-2 cells on biosiliceous matrices hydroxyapatite formation is induced, while syntheses of cartilaginous proteoglycans and sulfated glycosaminoglycans are down-regulated. Furthermore, quantitative real-time RT-PCR analysis revealed a strong time-depended increase in expression of OPG in biosilica exposed SaOS-2 cells while the steady-state e…
Direct Visualization of Molecule Deprotonation on an Insulating Surface
2012
Elucidating molecular-scale details of basic reaction steps on surfaces is decisive for a fundamental understanding of molecular reactivity within many fields, including catalysis and on-surface synthesis. Here, the deprotonation of 2,5-dihydroxybenzoic acid (DHBA) deposited onto calcite (101;4) held at room temperature is followed in situ by noncontact atomic force microscopy. After deposition, the molecules form two coexisting phases, a transient striped phase and a stable dense phase. A detailed analysis of high-resolution noncontact atomic force microscopy images indicates the transient striped phase being a bulk-like phase, which requires hydrogen bonds between the carboxylic acid moie…