Search results for "Measure"
showing 10 items of 4687 documents
Top-quark mass measurements at the LHC: alternative methods
2016
Alternative top quark mass determinations can provide inputs to the world average with orthogonal systematic uncertainties and may help to refine the interpretation of the standard method. Among a number of recent results I focus on the extractions by ATLAS and CMS of the top quark pole mass from the top quark pair and tt + 1 jet production cross-section, which have now reached a precision of 1%. Alternative top quark mass determinations can provide inputs to the world average with orthogonal systematic uncertainties and may help to refine the interpretation of the standard method. Among a number of recent results I focus on the extractions by ATLAS and CMS of the top quark pole mass from t…
Erythrocytes labeled with [18F]SFB as an alternative to radioactive CO for quantification of blood volume with PET
2013
Inhaled radioactive CO is currently the tracer of choice for blood volume quantification by positron emission tomography (PET). This measurement is of great interest for several clinical and research applications. However, owing to the short half-life of the radiolabeled CO, it can only be used in centers equipped with a cyclotron. In the present work, we propose an alternative method to label the red blood cells with [(18) F] in order to obtain blood volume measurements by PET. The use of the radioactive synthon [(18) F] N-succinimidyl 4-[(18) F]fluorobenzoate ([(18) F]SFB) was evaluated for erythrocyte labeling and PET blood volume imaging. The images provided by [(18) F]SFB labeled eryth…
Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly
2001
The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10–800 μg l−1 of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput …
A qualitative examination of performance and energy yield of photovoltaic modules in southern Norway
2010
Three different, commercially available photovoltaic modules have been monitored outdoors in the town of Grimstad, Norway. The present paper describes the experimental setup that was implemented, in particular details of the low-cost electronic loads. Results compare measured performance with manufacturer's data, and temperature measurements enable a comparison with performance at standard test condition temperature. Overall, the monocrystalline module performed best both regarding maximum efficiency and overall energy production, whereas the module based on triple junction amorphous silicon technology had the worst performance considering these criteria. The gross numbers of energy yield c…
Comparison between textured SnO2:F and Mo contacts with the p-type layer in p–i–n hydrogenate amorphous silicon solar cells by forward bias impedance…
2013
Abstract In this paper we compare the performance of the textured SnO2:F and Mo contacts with the p-type layer in p–i–n hydrogenate amorphous silicon (a-Si:H) solar cells. We use standard current–voltage (I–V) electrical characterization methods coupled with forward bias small signal impedance analysis. We show the efficacy of this technique to determine the effective carrier lifetime in photovoltaic cells. We show that such effective lifetimes are indeed directly connected to the respective dark diode saturation currents. We also find that the effective lifetime is constant with the temperature in the 0–70 °C range and it is significantly better for the solar cell with Mo diode contact. Th…
Development of a test station for accurate in situ I-V curve measurements of photovoltaic modules in Southern Norway
2011
The development of an outdoor test station for accurate in situ I-V curve measurements of photovoltaic (PV) modules is described. The modules are installed in an open-rack configuration at the University of Agder in Southern Norway. Seven new and three aged PV modules of different type and make are being tested, including mono-and multicrystalline silicon from differing manufacturing routes, triple-junction amorphous silicon, and CIS. Data acquisition is controlled with a multichannel electronic load system and LabVIEW software, recording high-resolution I-V curves at one-minute intervals. Between I-V curve sweeps, each module is operated at the maximum power point. Characteristic electrica…
Influence of the electro-optical properties of an a-Si:H single layer on the performances of a pin solar cell
2012
We analyze the results of an extensive characterization study involving electrical and optical measurements carried out on hydrogenated amorphous silicon (α-Si:H) thin film materials fabricated under a wide range of deposition conditions. By adjusting the synthesis parameters, we evidenced how conductivity, activation energy, electrical transport and optical absorption of an α-Si:H layer can be modified and optimized. We analyzed the activation energy and the pre-exponential factor of the dark conductivity by varying the dopant-to-silane gas flow ratio. Optical measurements allowed to extract the absorption spectra and the optical bandgap. Additionally, we report on the temperature dependen…
Beneficial impact of wave-breaking for coherent continuum formation in normally dispersive nonlinear fibers
2008
International audience; We study the evolution of a pulse propagating in a normally dispersive fiber in the presence of Kerr nonlinearity. We review the temporal and spectral impact of optical wave-breaking in the development of a continuum. The impact of linear losses or gain is also investigated.
Optical gain, spontaneous and stimulated emission of surface plasmon polaritons in confined plasmonic waveguide
2010
International audience; We develop a theoretical model to compute the local density of states in a confined plasmonic waveguide. Based on this model, we derive a simple formula with a clear physical interpretation for the lifetime modification of emitters embedded in the waveguide. The gain distribution within the active medium is then computed following the formalism developed in a recent work [Phys. Rev. B 78, 161401 (2008)], by taking rigorously into account the pump irradiance and emitters lifetime modifications in the system. We finally apply this formalism to describe gain–assisted propagation in a dielectric–loaded surface plasmon polariton waveguide.
On the enhancement of diffusion by chaos, escape rates and stochastic instability
1999
We consider stochastic perturbations of expanding maps of the interval where the noise can project the trajectory outside the interval. We estimate the escape rate as a function of the amplitude of the noise and compare it with the purely diffusive case. This is done under a technical hypothesis which corresponds to stability of the absolutely continuous invariant measure against small perturbations of the map. We also discuss in detail a case of instability and show how stability can be recovered by considering another invariant measure.