New Results on High-Resolution 3-D CZT Drift Strip Detectors
2020
Intense research activities have been carry out in the development of room temperature gamma ray spectroscopic imagers, aiming to compete with the excellent energy resolution of high-purity germanium (HPGe) detectors (0.3 % FWHM at 662 keV) obtained after cryogenic cooling. Cadmium-zinc-telluride (CZT) detectors equipped with pixel, strip and virtual Frisch-grid electrode structures represented an appealing solution for room temperature measurements. In this work, we present the performance of new high-resolution CZT drift strip detectors (19.4 x 19.4 x 6 mm3), recently fabricated at IMEM-CNR of Parma (Italy) in collaboration with due2lab company (Reggio Emilia, Italy). The detectors, worki…
Environmental chamber for an atomic force microscope.
2007
A commercial atomic force microscope (AFM), originally designed for operation in ambient conditions, was placed inside a compact aluminum chamber, which can be pumped down to high vacuum levels or filled with a desired gaseous atmosphere, including humidity, up to normal pressure. The design of this environmental AFM is such that minimal intrusion is made to the original setup, which can be restored easily. The performance inside the environmental chamber is similar to the original version.
Pressure sensor development based on Dielectric Electro Active Polymers
2012
The Dielectric Electro Active Polymer's (DEAP's) sensing capabilities is one of the main trio-characteristics of the material applicable area's, the trio-formations as applicable use are actuator, transducer and last but not least sensor. It is noted here that one of the main value propositions whenever DEAP material is used is the dual characteristics as the sensing/actuating capability.
2021
Gold-assisted mechanical exfoliation currently represents a promising method to separate ultralarge (centimeter scale) transition metal dichalcogenide (TMD) monolayers (1L) with excellent electronic and optical properties from the parent van der Waals (vdW) crystals. The strong interaction between Au and chalcogen atoms is key to achieving this nearly perfect 1L exfoliation yield. On the other hand, it may significantly affect the doping and strain of 1L TMDs in contact with Au. In this paper, we systematically investigated the morphology, strain, doping, and electrical properties of large area 1L MoS2 exfoliated on ultraflat Au films (0.16-0.21 nm roughness) and finally transferred to an i…
High Voltage Metrology with Collinear Laser Spectroscopy
2018
We present results of laser spectroscopic high voltage measurements on the 5 ppm relative uncertainty level using a pump and probe scheme on Ca+ ions. With the two-stage laser interaction and with a reference measurement we can eliminate systematic effects like differences in contact potentials of electrode materials, thermo-electric voltages, and the unknown starting potential of the ions in the ion source. Our measurements are compatible with the 5 ppm precision limits of the high voltage dividers used for comparison and demonstrate an unprecedented increase in the accuracy of laser-based high voltage measurements by a factor of 20.
Improvement of building wall surface temperature measurements by infrared thermography
2005
By using quantitative thermal scanning of building surface structures, it is possible to access the temperature field. For further calculation of the heat flux exchanged by these structures with the environment, one must quantify as finely as possible the temperature field on the bodies surfaces. For this purpose we have to take into account that real bodies are not black, which implies that a part of the ambient radiation received by the infrared camera detectors is reflected radiation. In this paper, we present a method to quantify the reflected flux by using an infrared mirror, which allows large surface temperature measurements by infrared thermography under near-ambient conditions with…
A magnetostrictive sensor interrogated by fiber gratings for DC-current and temperature discrimination
2000
A magnetostrictive sensor head with temperature compensation has been developed for measurement of static magnetic fields. The device consists on two different alloys with similar thermal expansion coefficient one of which has a giant magnetostriction, the expansion of both materials produced by heat and magnetism is detected by two fiber gratings. One of the gratings measures the temperature of the sensor and the difference between the wavelengths reflected by the gratings is a measurement of the magnetically induced strain.
Magnetic Field Gradiometer with Sub-Micron Spatial Resolution Based on Caesium Vapour in an Extremely Thin Cell
2015
Abstract In this paper we present a device for measuring the magnetic field and its gradient with a spatial resolution of several hundred nanometres. This device is based on caesium metal vapour confined to an extremely thin cell (ETC). To measure magnetic signals, we use absorption and very low laser powers, which might be appealing for modern fabrication techniques. A portable, fully automated device was constructed.
High Temperature SiC Blocking Diodes for Solar Array
2009
This paper presents the results of an experimental investigation of the performance of 300V-5A Silicon Carbide Ni and W Schottky diode operating in the range between -170°C to 270°C. We have developed these diodes as blocking diodes, for solar cell array protection in order to fulfill the BepiColombo mission specifications. An electro-thermal characterization has been performed taking into account the harsh condition of the mission (high temperature range and electrical stress). The destructive and non-destructive tests have assured that the designed SiC diodes are able to support the electro-thermal limits. A reliability test has also been performed to investigate the stability of forward …
Low Cost Electrical Current Sensors with Extremely Wide Measurement Range
2015
A new electrical current measurement system is presented. It features the ability to dynamically and automatically change its measurement range to the sensed current amplitude without user action. It also exhibits galvanic isolation and near zero insertion loss characteristics.