Search results for "Medical physics"
showing 10 items of 579 documents
Decompositions of Weakly Compact Valued Integrable Multifunctions
2020
We give a short overview on the decomposition property for integrable multifunctions, i.e., when an &ldquo
Evaluation of DR and CR digital mammography systems based on phantom and breast dosimetry.
2006
Digital mammography has been progressively introduced in screening centers, since recent evolution of CR and DR detectors. However, it is questionable which exposure conditions would be more suitable when these techniques are applied, in order to reduce the glandular breast doses, as they are related with induced carcinogenesis. Several exposures have been performed in CR and DR mammography units for comparing absorbed doses during quality control assessments and during screening, diagnosis and treatment. In the first case, the CIRS11A mammographic phantom has been used with standard exposure conditions (28 kV, AEC mode with blackening +0, 50:50 glandularity and 4.5 compressed breast thickn…
A nanodosimetric model of radiation-induced clustered DNA damage yields
2010
International audience; We present a nanodosimetric model for predicting the yield of double strand breaks (DSBs) and non-DSB clustered damages induced in irradiated DNA. The model uses experimental ionization cluster size distributions measured in a gas model by an ion counting nanodosimeter or, alternatively, distributions simulated by a Monte Carlo track structure code developed to simulate the nanodosimeter. The model is based on a straightforward combinatorial approach translating ionizations, as measured or simulated in a sensitive gas volume, to lesions in a DNA segment of one-two helical turns considered equivalent to the sensitive volume of the nanodosimeter. The two model paramete…
Additional file 1: Figure S1. of Mycobacterium tuberculosis secretory proteins downregulate T cell activation by interfering with proximal and downst…
2015
(A-C) Lymphocyte transformation test for dose optimisation of Ag85A, ESAT-6 and H37Rv by using PBMCs of healthy individuals (N = 10) and pulmonary TB (N = 10) patients using H3-thymidine uptake assay. PHA and PPD were used as positive control and wells with unstimulated cells were taken as control. Lymphoproliferative responses of healthy individuals and pulmaonary TB patients were calculated using different concentration (2.5, 5, 7.5, 10, 15, μg/ml) of antigens. Bar diagram showing mean ± SEM of stimulation indices (S.I) of stimulated PBMC’s with different doses of PHA, PPD, A85A, ESAT-6 and H37Rv. S.I was calculated according to the formula: S I = Mean counts per minute of experimental we…
A theoretical approach of the propagation through geometrical constraints in cardiac tissue
2007
International audience; The behaviour of impulse propagation in the presence of non-excitable scars and boundaries is a complex phenomenon and induces pathological consequences in cardiac tissue. In this article, a geometrical con¯guration is considered so that cardiac waves propagate through a thin strand, which is connected to a large mass of cells. At this interface, waves can slow down or even be blocked depending on the width of the strand. We present an analytical approach leading to determine the blockade condition, by introducing planar travelling wavefront and circular stationary wave. Eventually, the in°uence of the tissue geometry is examined on the impulse propagation velocity.
Advances in liver US, CT, and MRI: moving toward the future
2021
AbstractOver the past two decades, the epidemiology of chronic liver disease has changed with an increase in the prevalence of nonalcoholic fatty liver disease in parallel to the advent of curative treatments for hepatitis C. Recent developments provided new tools for diagnosis and monitoring of liver diseases based on ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI), as applied for assessing steatosis, fibrosis, and focal lesions. This narrative review aims to discuss the emerging approaches for qualitative and quantitative liver imaging, focusing on those expected to become adopted in clinical practice in the next 5 to 10 years. While radiomics is an emergin…
Investigation of superspreading COVID-19 outbreak events in meat and poultry processing plants in Germany: A cross-sectional study.
2020
Since May 2020, several COVID-19 outbreaks have occurred in the German meat industry despite various protective measures, and temperature and ventilation conditions were considered as possible high-risk factors. This cross-sectional study examined meat and poultry plants to examine possible risk factors. Companies completed a self-administered questionnaire on the work environment and protective measures taken to prevent SARS-CoV-2 infection. Multivariable logistic regression analysis adjusted for the possibility to distance at least 1.5 meters, break rules, and employment status was performed to identify risk factors associated with COVID-19 cases. Twenty-two meat and poultry plants with 1…
Dosimetry in mixed gamma–neutron radiation fields and energy compensation filters for CaF2:Tm TL detectors
2008
Abstract Strong fields of thermal and epithermal neutrons as used for Boron Neutron Capture Therapy (BNCT) show a relatively small gamma dose. However, for accurate dose estimation, both the neutron as well as the gamma component has to be considered. Different approaches have been studied with various thermoluminescence detectors (TLDs). As a result, CaF2:Tm detectors (TLD-300) are attributed to be most insensitive to thermal neutrons but not tissue-equivalent. In this paper we focus on the measurement of the gamma dose with TLD-300 in mixed irradiation fields. To overcome the disadvantage of being not tissue-equivalent, a study on energy compensation filters was performed. The paper compr…
Exposure of -alanine and -ammonium tartrate ESR dosimeters to thermal neutrons: Experiments and Monte Carlo simulations
2008
Abstract Electron spin resonance solid state dosimetry with alanine and ammonium tartrate pellets is a valuable tool in both medical and industrial applications when dealing with photon and charged particle beams. Its use in neutron beams is limited by the low nuclear cross section values of atoms in the pellets. Addition of boron (10B) or gadolinium ( Gd 2 O 3 ) , known to have high neutron capture cross sections, has been proposed to improve neutron sensitivity. In this paper we present the results of an experimental study concerning neutron sensitivity vs. gadolinium concentration in dosimeter mixtures, with the aim of optimizing mixture composition and maximizing the electron spin resol…
Impact of prompt gamma emission of 44Sc on quantification in preclinical and clinical PET systems
2021
Abstract 44Sc is an increasingly investigated positron emitter for use in positron emission tomography (PET) imaging. However, 44Sc is a non-pure positron emitter, since prompt photons are co-emitted during the decay process. This study investigates coincidence energy spectra of 44Sc and its impact on PET quantification on a preclinical and clinical PET system in comparison with 18F. The raw data of the coincidence events revealed characteristic differences comparing the photon energy distribution of 44Sc and 18F. Due to prompt gamma emission of 44Sc, activity recovery is underestimated on PET systems. However, clinical PET imaging of 44Sc with acceptable quantitative accuracy appears feasi…