Search results for "Method"
showing 10 items of 13253 documents
Classification of Extra Virgin Olive Oils Produced at La Comunitat Valenciana According to Their Genetic Variety Using Sterol Profiles Established by…
2009
A method to classify extra virgin olive oils (EVOOs) according to their genetic variety using sterol profiles obtained by high-performance liquid chromatography (HPLC) with mass spectrometry (MS) detection has been developed. Sterol extracts were chromatographed on a dC18 Atlantis column (100x3 mm, 3 microm) with a gradient of acetonitrile/water (0.01% acetic acid) at a flow rate of 1.0 mL min(-1) and positive-ion mode MS detection. Using linear discriminant analysis of the HPLC-MS data (extracted ion chromatograms), EVOO samples belonging to six genetic varieties cultivated at La Comunitat Valenciana, Spain (Arbequina, Borriolenca, Canetera, Farga, Picual, and Serrana), were correctly clas…
Simultaneous dissolution profiles of two drugs in pharmaceutical formulations by an FIA manifold
2002
Abstract This article deals with the simultaneous determination of dissolution profiles of two drugs with overlapped spectra, present in the same pharmaceutical formulation. The official procedure for the dissolution profile is adapted to the continuous-flow methodology; the dissolution vessel is connected to an FIA manifold, in which the sample aliquots from the dissolution vessel are treated in order to adjust to the suitable pH and dilution degree to be monitored. The resulting solution is injected into the carrier stream, an acetic acid–acetate buffer at pH 4.3 and forced to the flow-cell of the spectrophotometer. The simultaneous determination of both profiles is based on the first der…
Program for the interpretive optimization of two-dimensional resolution.
2016
The challenge of fully optimizing LC × LC separations is horrendous. Yet, it is essential to address this challenge if sophisticated LC × LC instruments are to be utilized to their full potential in an efficient manner. Currently, lengthy method development is a major obstacle to the proliferation of the technique, especially in industry. A program was developed for the rigorous optimization of LC × LC separations, using gradient-elution in both dimensions. The program establishes two linear retention models (one for each dimension) based on just two LC × LC experiments. It predicts LC × LC chromatograms using a simple van-Deemter model to generalize band-broadening. Various objectives (ana…
Staining mitochondria in Saccharomyces cerevisiae.
1969
After testing various procedures (amidoblack 10B, acid fuchsin-methyl blue, Luxol fast blue MBS-phloxine, toluidine blue O, Jams green B and pinacyanol), three stains can be recommended for staining both types of mitochondria (globose and threadlike) in the cells of Saccharomyces cerevisiae: (1) 0.1% solution of amidoblack 10B in citrate buffer (pH 3.0) for 10 min; (2) 0.01% solution of toluidine blue O in phosphate buffer (pH 6.0) for 30 min; (3) 0.01% solution of Janus green B in distilled water (pH 5.6) for 30 min. The latter stain is most specific because its staining reaction depends upon the action of the mitochondrial enzyme cytochrome c oxidase. Yet, low concentrations and short inc…
Spectrophotometric Determination of the Antihistamines, Carbinoxamine Maleate and Doxylamine Succinate, in anN-Cetylpyridinium Chloride Micellar Medi…
1996
Abstract The pyridine antihistamines carbinoxamine maleate and doxylamine succinate were derivatized by hydrolysis with cyanogen bromide and coupling with aniline to form a polymethine dye, and determined by colorimetry. In a micellar cationic medium of N-cetylpyridinium chloride (NCPC), the reaction times were reduced and the sensitivities improved. In 0.1 M NCPC the apparent molar absorptivities of the derivatives were 5,900 and 3,500 M−1 cm−1, and the limits of detection (as 3s) were 8.6x10−7 M and 1.7x106 M, for carbinoxamine and doxylamine, respectively. The sensitivity was enhanced in a three- to six-fold factor with respect to a non-micellar medium. The reproducibility was 0.8% for 1…
Characteristic Topological Features of Promoter Capture Hi-C Interaction Networks
2020
Current Hi-C technologies for chromosome conformation capture allow to understand a broad spectrum of functional interactions between genome elements. Although significant progress has been made into analysis of Hi-C data to identify the biologically significant features, many questions still remain open. In this paper we describe analysis methods of Hi-C (specifically PCHi-C) interaction networks that are strictly focused on topological properties of these networks. The main questions we are trying to answer are: (1) can topological properties of interaction networks for different cell types alone be sufficient to distinguish between these types, and what the most important of such propert…
Cadmium and lead in infant cereals — electrothermal-atomic absorption spectroscopic determination
1999
Because infant cereals are an important component of the infant diet from the fourth month of life onwards and therefore contribute to the dietetic intake of metals by infants, cadmium and lead were measured in samples of cereals commercially available in Spain. For this purpose an electrothermal atomic absorption (ET-AAS) method for determining cadmium and lead in these products was studied. The ET-AAS instrumental conditions and temperature/time furnace program were selected. The analytical parameters of the method (linearity, detection and quantification limits and precision) show its usefulness in measuring cadmium and lead in infant cereal products. The method was applied to eight diff…
Antennas for the detection of radio emission pulses from cosmic-ray induced air showers at the Pierre Auger Observatory.
2012
The Pierre Auger Observatory is exploring the potential of the radio detection technique to study extensive air showers induced by ultra-high energy cosmic rays. The Auger Engineering Radio Array (AERA) addresses both technological and scientific aspects of the radio technique. A first phase of AERA has been operating since September 2010 with detector stations observing radio signals at frequencies between 30 and 80 MHz. In this paper we present comparative studies to identify and optimize the antenna design for the final configuration of AERA consisting of 160 individual radio detector stations. The transient nature of the air shower signal requires a detailed description of the antenna s…
Measurement of the radiation energy in the radio signal of extensive air showers as a universal estimator of cosmic-ray energy
2016
We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8±0.7(stat)±6.7(syst) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principles calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the d…
Searches for Large-Scale Anisotropy in the Arrival Directions of Cosmic Rays Detected above Energy of $10^{19}$ eV at the Pierre Auger Observatory an…
2014
Spherical harmonic moments are well-suited for capturing anisotropy at any scale in the flux of cosmic rays. An unambiguous measurement of the full set of spherical harmonic coefficients requires full-sky coverage. This can be achieved by combining data from observatories located in both the northern and southern hemispheres. To this end, a joint analysis using data recorded at the Telescope Array and the Pierre Auger Observatory above 1019 eV is presented in this work. The resulting multipolar expansion of the flux of cosmic rays allows us to perform a series of anisotropy searches, and in particular to report on the angular power spectrum of cosmic rays above 1019 eV. No significant devia…