Metrological performances of voltage and current instrument transformers in harmonics measurements
2018
In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by usin…
Autonomous 3D geometry reconstruction through robot-manipulated optical sensors
2021
Abstract Many industrial sectors face increasing production demands and need to reduce costs, without compromising the quality. Whereas mass production relies on well-established protocols, small production facilities with small lot sizes struggle to update their highly changeable production at reasonable costs. The use of robotics and automation has grown significantly in recent years, but extremely versatile robotic manipulators are still not commonly used in small factories. Beside of the investments required to enable efficient and profitable use of robot technology, the efforts needed to program robots are only economically viable in case of large lot sizes. Generating robot programs f…
A new Collinear Apparatus for Laser Spectroscopy and Applied Science (COALA).
2020
We present a new collinear laser spectroscopy setup that has been designed to overcome systematic uncertainty limits arising from high-voltage and frequency measurements, beam superposition, and collisions with residual gas that are present in other installations utilizing this technique. The applied methods and experimental realizations are described, including an active stabilization of the ion-source potential, new types of ion sources that have not been used for collinear laser spectroscopy so far, dedicated installations for pump-and-probe measurements, and a versatile laser system referenced to a frequency comb. The advanced setup enables us to routinely determine transition frequenci…
Excess electronic recoil events in XENON1T
2020
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4$\sigma$ significance, and a 3D 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae}<3.8 \times 10^{-12}$,…
Genuine tripartite entanglement in a spin-star network at thermal equilibrium
2010
In a recent paper [M. Huber {\it et al}, Phys. Rev. Lett. {\bf 104}, 210501 (2010)] new criteria to find out the presence of multipartite entanglement have been given. We exploit these tools in order to study thermal entanglement in a spin-star network made of three peripheral spins interacting with a central one. Genuine tripartite entanglement is found in a wide range of the relevant parameters. A comparison between predictions based on the new criteria and on the tripartite negativity is also given.
Doppler-free two-photon spectrum of SF_6 for metrological purposes
1998
We report on our systematic investigation of strong Doppler-free two-photon absorption in the middle infrared. The absorption frequencies for two counterpropagating waves of identical frequencies are predicted. Five of these transitions were observed with sub-Doppler resolution with a sideband CO(2) laser and were measured with 10-kHz accuracy. Knowledge of these strong two-photon absorptions frequencies will allow the improvement of secondary frequency standards in the infrared.
High Voltage Metrology with Collinear Laser Spectroscopy
2018
We present results of laser spectroscopic high voltage measurements on the 5 ppm relative uncertainty level using a pump and probe scheme on Ca+ ions. With the two-stage laser interaction and with a reference measurement we can eliminate systematic effects like differences in contact potentials of electrode materials, thermo-electric voltages, and the unknown starting potential of the ions in the ion source. Our measurements are compatible with the 5 ppm precision limits of the high voltage dividers used for comparison and demonstrate an unprecedented increase in the accuracy of laser-based high voltage measurements by a factor of 20.
An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
2008
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Readout of quantum information spreading using a disordered quantum walk
2021
We design a quantum probing protocol using quantum walks to investigate the quantum information spreading pattern. We employ quantum Fisher information as a figure of merit to quantify extractable information about an unknown parameter encoded within the quantum walk evolution. Although the approach is universal, we focus on the coherent static and dynamic disorder to investigate anomalous and classical transport as well as Anderson localization. We provide a feasible experimental strategy to implement, in principle, the quantum probing protocol based on the quantum Fisher information using a Mach–Zehnder-like interferometric setup. Our results show that a quantum walk can be considered as …
Self-sustained coherent phonon generation in optomechanical cavities
2016
Optical forces can set tiny objects in states of mechanical self-sustained oscillation, spontaneously generating periodic signals by extracting power from steady sources. Miniaturized self-sustained coherent phonon sources are interesting for applications such as mass-force sensing, intra-chip metrology and intra-chip time-keeping among others. In this paper, we review several mechanisms and techniques that can drive a mechanical mode into the lasing regime by exploiting the radiation pressure force in optomechanical cavities, namely stimulated emission, dynamical back-action, forward stimulated Brillouin scattering and self-pulsing.