Search results for "Microfluidic"
showing 10 items of 148 documents
One-piece micropumps from liquid crystalline core-shell particles
2012
Responsive polymers are low-cost, light weight and flexible, and thus an attractive class of materials for the integration into micromechanical and lab-on-chip systems. Triggered by external stimuli, liquid crystalline elastomers are able to perform mechanical motion and can be utilized as microactuators. Here we present the fabrication of one-piece micropumps from liquid crystalline core-shell elastomer particles via a microfluidic double-emulsion process, the continuous nature of which enables a low-cost and rapid production. The liquid crystalline elastomer shell contains a liquid core, which is reversibly pumped into and out of the particle by actuation of the liquid crystalline shell i…
Asymmetric nanopore rectification for ion pumping, electrical power generation, and information processing applications
2011
Single-track, asymmetric nanopores can currently be functionalised with a spatially inhomogeneous distribution of fixed charges and a variety of pore tip shapes. Optimising the asymmetric nanopore characteristics is crucial for practical applications in nanofluidics. We have addressed here this question for three cases based on different input/output chemical and electrical signals: (i) ion pumping up a concentration gradient by means of a periodic, time-dependent bias potential, (ii) information processing with a single nanopore acting as the nanofluidic diode of a logic gate, and (iii) electrical energy harvesting using a nanopore that separates two solutions of different salt concentrati…
Production of polymeric micro- and nanostructures with tunable properties as pharmaceutical delivery systems
2020
Abstract The production of novel graft copolymers based on poly-e-caprolactone (PCL) and polyaspartamide are useful to realize structures for potential biomedical applications. Here, the synthesis of pegylated PCL/polyhydroxyethyl aspartamide (PHEA) graft copolymers (PHEA-g-SUCC-PCL-g-PEG) with tunable composition, was achieved by followpling a synthetic strategy that involved first the grafting of preformed PCL on PHEA backbone, then polyethylen glycol (PEG), by using 1,1′-carbonyldiimidazole (CDI) to speed up the condensation reaction. Graft copolymers with a Derivatization Degree (DD) in PCL ranging between 1.1 and 4.4 mol% were obtained, and processable with different technologies for t…
Neurohybrid Memristive CMOS-Integrated Systems for Biosensors and Neuroprosthetics
2020
Here we provide a perspective concept of neurohybrid memristive chip based on the combination of living neural networks cultivated in microfluidic/microelectrode system, metal-oxide memristive devices or arrays integrated with mixed-signal CMOS layer to control the analog memristive circuits, process the decoded information, and arrange a feedback stimulation of biological culture as parts of a bidirectional neurointerface. Our main focus is on the state-of-the-art approaches for cultivation and spatial ordering of the network of dissociated hippocampal neuron cells, fabrication of a large-scale cross-bar array of memristive devices tailored using device engineering, resistive state program…
Fabrication of a negative PMMA master mold for soft-lithography by MeV ion beam lithography
2012
Abstract In this study, poly(methyl methacrylate) (PMMA) was investigated as a negative resist by irradiation with a high-fluence 2 MeV proton beam. The beam from a 1.7 MV Tandetron accelerator at the Plasma and Beam Physics Research Facility (PBP) of Chiang Mai University is shaped by a pair of computer-controlled L-shaped apertures which are used to expose rectangular pattern elements with 1–1000 μm side length. Repeated exposure of rectangular pattern elements allows a complex pattern to be built up. After subsequent development, the negative PMMA microstructure was used as a master mold for casting poly(dimethylsiloxane) (PDMS) following a standard soft-lithography process. The PDMS chi…
Development of procedures for programmable proximity aperture lithography
2013
Abstract Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyvaskyla and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeata…
Laser Microdissection of the Alveolar Duct Enables Single-Cell Genomic Analysis
2014
Complex tissues such as the lung are composed of structural hierarchies such as alveoli, alveolar ducts, and lobules. Some structural units, such as the alveolar duct, appear to participate in tissue repair as well as the development of bronchioalveolar carcinoma. Here, we demonstrate an approach to conduct laser microdissection of the lung alveolar duct for single-cell PCR analysis. Our approach involved three steps. The initial preparation used mechanical sectioning of the lung tissue with sufficient thickness to encompass the structure of interest. In the case of the alveolar duct, the precision-cut lung slices were 200µm thick; the slices were processed using near-physiologic conditions…
Margination of Fluorescent Polylactic Acid-Polyaspartamide based Nanoparticles in Microcapillaries In Vitro: the Effect of Hematocrit and Pressure.
2017
The last decade has seen the emergence of vascular-targeted drug delivery systems as a promising approach for the treatment of many diseases, such as cardiovascular diseases and cancer. In this field, one of the major challenges is carrier margination propensity (i.e., particle migration from blood flow to vessel walls); indeed, binding of these particles to targeted cells and tissues is only possible if there is direct carrier–wall interaction. Here, a microfluidic system mimicking the hydrodynamic conditions of human microcirculation in vitro is used to investigate the effect of red blood cells (RBCs) on a carrier margination in relation to RBC concentration (hematocrit) and pressure drop…
Core-Shell Microgels with Switchable Elasticity at Constant Interfacial Interaction.
2016
Hydrogels based on poly(N-isopropylacrylamide) (pNIPAAm) exhibit a thermo-reversible volume phase transition from swollen to deswollen states. This change of the hydrogel volume is accompanied by changes of the hydrogel elastic and Young's moduli and of the hydrogel interfacial interactions. To decouple these parameters from one another, we present a class of submillimeter sized hydrogel particles that consist of a thermosensitive pNIPAAm core wrapped by a nonthermosensitive polyacrylamide (pAAm) shell, each templated by droplet-based microfluidics. When the microgel core deswells upon increase of the temperature to above 34 °C, the shell is stretched and dragged to follow this deswelling i…
Tuning the defect configurations in nematic and smectic liquid crystalline shells
2013
Thin liquid crystalline shells surrounding and surrounded by aqueous phases can be conveniently produced using a nested capillary microfluidic system, as was first demonstrated by Fernandez-Nieves et al. in 2007. By choosing particular combinations of stabilizers in the internal and external phases, different types of alignment, uniform or hybrid, can be ensured within the shell. Here, we investigate shells in the nematic and smectic phases under varying boundary conditions, focusing in particular on textural transformations during phase transitions, on the interaction between topological defects in the director field and inclusions in the liquid crystal (LC), and on the possibility to rel…