Search results for "Microscope"

showing 10 items of 1412 documents

In vitro evaluation of efficacy of different rotary instrument systems for gutta percha removal during root canal retreatment

2016

Background: Complete removal of old filling material during root canal retreatment is fundamental for predictable cleaning and shaping of canal anatomy. Most of the retreatment methods tested in earlier studies have shown inability to achieve complete removal of root canal filling. Therefore the aim of this investigation was to assess the efficacy of three different rotary nickel titanium retreatment systems and Hedstrom files in removing filling material from root canals. Material and Methods: Sixty extracted mandibular premolars were decoronated to leave 15 mm root. Specimen were hand instrumented and obturated using gutta percha and AH plus root canal sealer. After storage period of two …

biologybusiness.industryRoot canalResearcheducationAnova testDentistryOdontología030206 dentistryGutta-perchabiology.organism_classificationCiencias de la saludhumanitiesOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureStereo microscopemedicineUNESCO::CIENCIAS MÃ DICAS030212 general & internal medicine:CIENCIAS MÃ DICAS [UNESCO]businessGeneral DentistryMathematics
researchProduct

Microspectroscopy and spectromicroscopy with photoemission electron microscopy using a new kind of imaging energy filter

2001

The use of an imaging retarding field analyser attached to the FOCUS IS-PEEM is described. This kind of energy filter is a simple, powerful tool to obtain microspectra from areas of down to about 1 μm using (V)UV and X-ray excitation sources. First results of microspectroscopy measured by excitation with a laboratory as well as a synchrotron X-ray source are presented.

business.industryChemistryAnalyserSynchrotron radiationSurfaces and InterfacesCondensed Matter PhysicsSynchrotronSurfaces Coatings and Filmslaw.inventionPhotoemission electron microscopyOpticsX-ray photoelectron spectroscopyFilter (video)lawMaterials ChemistryElectron microscopebusinessExcitationSurface Science
researchProduct

Maxillary first molar with three mesiobuccal canals confirmed with spiral computer tomography

2012

Anatomic variations in root canal morphology have become easier to detect with the rapid advancements in clinical and diagnostic aids. Also an increased awareness of unusual anatomic morphology and a better understanding of the root canal system guides the clinician in diagnosis and treatment of such variations in order to achieve a successful endodontic outcome. Mesiobuccal root of first maxillary molar teeth have been considered to be one of the most complex and challenging root canal systems. This case report presents a successful management of a third canal in the mesiobuccal root of permanent maxillary first molar using dental operating microscope along with a modified access preparati…

business.industryRoot canalDentistryCase ReportOdontologíaRoot canal morphology:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludSpiral computed tomographymedicine.anatomical_structureMesiobuccal rootClinical and Experimental DentistryUNESCO::CIENCIAS MÉDICASotorhinolaryngologic diseasesMaxillary first molarMedicinesense organsTomographyDental operating microscopebusinessGeneral DentistrySpiral
researchProduct

High resolution electron microscopy of liquid crystalline polymers

1990

Les images de microscopie electronique a haute resolution des polymeres cristaux liquides calamitiques [CO−CH(R)−CO 2 −(CH 2 ) 6 −OPh−N:N−PhO−(CH 2 ) 6 −O] n (R=CH 2 −CH=CH 2 , (CH 2 ) 6 −O−Ph N=N−Ph−CN) et discotique poly (hexadecanedioate de triphenylene) sont simulees sur ordinateur et comparees avec les structures obtenues a partir des resultats experimentaux de diffraction electronique. Une theorie est developpee pour expliquer le bon accord observe

chemistry.chemical_classificationAzo polymerChemistryLiquid crystallineDiscotic liquid crystalHigh resolutionPolymerlaw.inventionHigh resolution electron microscopylawLiquid crystalPolymer chemistryPhysical chemistryElectron microscopeJournal de Physique
researchProduct

On-Surface Synthesis of Oligo(indenoindene)

2020

Fully conjugated ladder polymers (CLP) possess unique optical and electronic properties, and are considered promis-ing materials for applications in (opto)electronic devices. Poly(indenoindene) is a CLP consisting of an alternating array of five- and six-membered rings, which has remained elusive so far. Here, we report an on-surface synthesis of oligo(indenoindene) on Au(111). Its structure and a low elec-tronic bandgap have been elucidated by low-temperature scanning tunneling microscopy and spectroscopy and non-contact atomic force microscopy, complemented by density functional theory calculations. Achieving defect-free seg-ments of oligo(indenoindene) offers an exclusive insight into th…

chemistry.chemical_classificationBand gapAtomic force microscopy530 PhysicsElectronic bandNanotechnologyGeneral ChemistryPolymerConjugated system010402 general chemistry01 natural sciencesBiochemistryCatalysis0104 chemical scienceslaw.inventionColloid and Surface Chemistrychemistrylaw540 ChemistryDensity functional theoryScanning tunneling microscopeSpectroscopy
researchProduct

Studies of the Ca4Mn3O10structure obtained using high pressure and high temperature

2002

An ideal n = 3 member of the group of Ruddlesden?Popper (RP) phases Ca4Mn3O10 was obtained by solid-state reaction under high pressure. This phase has been studied by transmission electron microscopy, convergent beam electron microscopy, high-resolution transmission electron microscopy, and parallel electron energy-loss spectroscopy. The lattice parameters are derived as a = b = 0.37 nm and c = 2.69 nm with the space group I4/mmm, which is the space group of the ideal RP phase.

chemistry.chemical_classificationChemistryCrystal chemistryManganateAnalytical chemistryElectronCondensed Matter Physicslaw.inventionchemistry.chemical_compoundNuclear magnetic resonanceElectron diffractionlawTransmission electron microscopyGeneral Materials ScienceElectron microscopeSpectroscopyInorganic compoundJournal of Physics: Condensed Matter
researchProduct

Scanning tunneling microscopy investigation of tricycloquinazoline liquid crystals on gold

2000

Self-assembled monolayers (SAMs) of hexaalkylthioether derivatives of tricycloquinazoline (TCQ) on Au(111) and tungsten diselenide (WSe2) were investigated by scanning tunneling microscopy (STM). The Au(111) surfaces were found to be etched by the thioether containing solutions. Corroded surfaces which are similar to gold surfaces that were coated with SAMs of thiols or disulfides were revealed by STM. Atomic adsorption spectroscopy proved that an amount of gold that corresponds to ca. 30% of a monolayer was dissolved in the assembly solutions. On gold, the aromatic cores of the molecules were found to be in face-on orientation. The alkyl substituents were in most cases folded upwards and s…

chemistry.chemical_classificationChemistryMetals and AlloysSelf-assembled monolayerSurfaces and InterfacesSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialslaw.inventionCrystallographychemistry.chemical_compoundAdsorptionLiquid crystallawMonolayerMaterials ChemistryOrganic chemistryTungsten diselenideSelf-assemblyScanning tunneling microscopeAlkylThin Solid Films
researchProduct

Liquid/Gas and Liquid/Liquid Phase Equilibria of the System Water/Bovine Serum Albumin

2013

The thermodynamic behavior of the system H2O/BSA was studied at 25 °C within the entire composition range: vapor pressure measurements via head space sampling gas chromatography demonstrate that the attainment of equilibria takes more than one week. A miscibility gap was detected via turbidity and the coexisting phases were analyzed. At 6 °C the two phase region extends from ca. 34 to 40 wt % BSA; it shrinks upon heating. The polymer rich phase is locally ordered, as can be seen under the optical microscope using crossed polarizers. The Flory-Huggins theory turns out to be inappropriate for the modeling of experimental results. A phenomenological expression is employed which uses three adju…

chemistry.chemical_classificationChromatography GasChemistrySpinodal decompositionVapor pressureLiquid gasAnalytical chemistryWaterSerum Albumin BovinePolymerPolarizerSurfaces Coatings and Filmslaw.inventionOptical microscopelawPhase (matter)Materials ChemistryAnimalsThermodynamicsCattleGas chromatographyPhysical and Theoretical ChemistryThe Journal of Physical Chemistry B
researchProduct

Packings of an unidimensional regular pore structure as model packings in size-exclusion and inverse size-exclusion chromatography

1996

Using porous aluminas and aluminosilicates with a regular and well-defined pore structure an attempt was made to correlate the SEC data of polystyrenes with established theoretical models. The pore structure of the two types of packings was extensively characterized by means of transmission and scanning electron microscopy, nitrogen sorption and mercury porosimetry. The SEC distribution coefficients measured experimentally were correlated with the distribution coefficients calculated from the theoretical models for flexible polymers. A good correlation was observed for the packing of the simplest pore morphology, but remarkable deviations appeared for the materials with a more complex pore …

chemistry.chemical_classificationChromatographyChemistryScanning electron microscopeOrganic ChemistrySize-exclusion chromatographyInverseSorptionGeneral MedicinePolymerPorosimetryBiochemistryAnalytical ChemistryGel permeation chromatographyPorosityJournal of Chromatography A
researchProduct

Non-porous polybutadiene-coated silicas as stationary phases in reversed-phase chromatography

1990

Abstract Non-porous silica of mean particle diameter 1.7 μm (Monospher) was coated with polybutadiene (PBD) following a published procedure. The silicas were prepared with graduated polymer loads up to 8% (w/w). Examination of the PBD-coated packings by means of electron spectroscopy for chemical analysis, scanning electron microscopy, diffuse reflection infrared fourier transform spectroscopy and differential thermal gravimetry indicated that the optimum polymer load was between 1 and 3% (w/w) with regard to a dense coverage corresponding to an average layer thickness of about 4 nm. No silanophilic interactions could be monitored using 1–3% (w/w) coated silicas under reversed-phase conditi…

chemistry.chemical_classificationChromatographyScanning electron microscopeOrganic ChemistryAnalytical chemistryGeneral MedicinePolymerReversed-phase chromatographyBiochemistryElectron spectroscopyFourier transform spectroscopyAnalytical ChemistryPolybutadienechemistryDiffuse reflectionPorosityJournal of Chromatography A
researchProduct